Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Digital Oscilloscopes /
Digital Oscilloscopes

Serial Bus Analyzer
I2C Bus · CAN Bus SPI Bus FlexRay
CAN Bus
Serial Bus Analyzer - CAN -
Triggering and analysis for the Controller Area Network (CAN) bus widely used in automotive applications.
Serial Bus Analyzer
Triggering
  Trigger Setup Menu
Trigger Setup Menu
You can set the trigger conditions on each field of a CAN frame. For instance, the trigger can be activated at a specific ID or data field.
Analysis
  Display of Detailed Analysis Results and Waveform
Use long memory to acquire CAN bus waveform data and analyze the data in a time-series manner. Analysis results are then listed along with the waveform. Results include: ID and Data fields, ACK field status and other information.
Search
 
Data Search Setup Menu

Use the high-speed data search function to search all acquired frames.  Search for user-specified ID Field, Data Field, CRC Field or ACK Field code.  A magnified view of the frame found is shown in the Zoom window.  You can also search for error frame, or an indefinite state.  The stuff bit can be calculated and extracted from the frame data and represented as a waveform.

  DL7440/DL7480 DL1640/DL1640L DL7200
Max. sampling rate 2 GS/s 200 MS/s 2 GS/s
Analog bandwidth 500 MHz 200 MHz 500 MHz
Max. memory length 16 MW 32 MW 16 MW
CAN trigger type Start of Frame/Identifier/RTR/Data Field/Error Frame
Combination trigger ・CAN Only
・CAN on Pattern
・CAN -> Pattern
N.A. N.A.
Bit rate (Trigger, search) 10 k to 1 M
(setting resolution:0.5 μsec)
1 M, 500 k, 250 k, 125 k, 100 k,
95.2 k, 83.3 k, 50 k, 33.3 k
1 M, 500 k, 250 k, 125 k, 100 k, 83.3 k, 50 k, 33.3 k
Analysis results
(waveform & analysis)
Identifier/Data/ACK
Analysis results(details) Frame Type (Remote, Data, Error)/Number/Time from the reference point/Identifier/Data (Hex/Binary)/CRC (Hex)/ACK/Error Type (Active, Passive, Form, CRC, ACK)
Number of analyzable frames 16,000 16,000 8,000
CAN cursor
Display the selected field range and move bit-by-bit in the field
Search Identifier/RTR/Data Field/Error Frame
Field jump function Find the starting point of an ID, Control Field, Data Field, CRC field and ACK field
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  Serial Bus Analyzer
See Also...
DL Series Selection Guide
Find the right one for you!
more
Serial Bus Analyzer Selection Guide
For I2C, CAN, and SPI analysis
more
Probes for Digital Oscilloscopes
Supporting a variety of measurement
more
Accessories for DL series
Accessories other than probes
more
FAQ
For the DL series
more
Top of this page