Category Sitemap
Home / Our Businesses / Test & Measurement / Products / Data Acquisition Equipment /
PC-Based Measurement Instruments

WE7000
Module Specs
The channel number can be expanded to eight times the number listed below by connecting several modules together (when using the 8 slot measuring station). Click the model name to view the specifications in detail (PDF file).
Model Max. Sampling Rate Frequency Range Resolution No. of Channels Measurement Range Max. Memory (words) Spec
WE7311 1 GS/s DC to 400 MHz 8 bits 1 5 mV/div to 500 mV/div (1-2-5 steps) 2 M
WE7111 100 MS/s DC to 40 MHz 8 bits 1 5 mV/div to 5 V/div (1-2-5 steps) 100 k
WE7116 20 MS/s DC to 8MHz 12 bits 2 ±100 mV to 50 V (1-2-5 steps) 4 M
WE7275 1 MS/s DC to 400 kHz 14 bits 2 ±100 mV to 200 V (1-2-5 steps), 350 V 4 M
WE7273 100 kS/s During DC coupling: DC to 40 kHZ
During AC coupling: 0.1 Kz to 40 kHz
16 bits 8 ±50 mV to ±50 V (in 1-2-5 steps) 8 M
WE7271/
WE7272
100 kS/s DC to 40 kHz 16 bits 4 ±1 V to 20 V (1-2-5 steps), 35 V 4 M
WE7251 100 Ks/s DC to 10 kHz 16 bits 10 ±1 V to 20 V (1-2-5 steps) 1 M
The channel number can be expanded to eight times the number listed below by connecting several modules together (when using the 8 slot measuring station). Click the model name to view the specifications in detail (PDF file).
Model Input Signals Max. Measurement Interval Resolution No. of Channels Max. Memory (words) Spec
WE7235 Acceleration and voltage measurement DC to 40 kHz 16 bits 4 4 M
WE7241 Thermocouple (12 types),
DC voltage (Max. 50 Vrange)
0.5 s (0.2 s possible with 2 ch) to 60 s 14 bits (When DC is input) 10 -
WE7245 Strain (Isolated differential input),
Voltage (Max. 20 Vrange)
10 μs 14 bits (When DC is input) 4 2 M
Direct inputs from sensors are available without any signal conditioner.
The channel number can be expanded to eight times the number listed below by connecting several modules together (when using the 8 slot measuring station). Click the model name to view the specifications in detail (PDF file).
Model Output Waveform Oscillation Frequency Range D/A Resolution No. of Channels Output Range Spec
WE7121 sine wave/square wave/triangle wave/ramp wave/pulse wave/arbitrary wave sine wave: 1 μHz to 10 MHz,
other waveforms: 1 μHz to 200 kHz
12 bits (Characters included) 1 ±10 V (setting resolution: 1 mV)
WE7281/
WE7282
sine wave/pulse wave/ramp wave/triangle wave/arbitrary wave/DC sine wave: 1 mHz to 20 kHz
other waveforms: 1 MHz to 10 kHz
16 bits (Characters included) 4 ±10 V (1-2-5 steps)
Click the model name to view the specifications in detail (PDF file).
Model Function Baud rate Spec
WE7081 CAN Data Acquisition, CAN Data Output, Module Linking 10 kHz to 1 MHz Hi-Speed CAN (ISO11898)
Click the model name to view the specifications in detail (PDF file).
Model Function Input/Output Dots Other Spec
WE7262 Digital signal input/output (with a counter) 32 Measurement interval when measuring input pattern continuously: 10 ms to 10 s, Channel number of counter: 2
Click the model name to view the specifications in detail (PDF file).
Model Function No. of Channels Input Sensitivity Min. Input Pulse Width Spec
WE7141 frequency/interval/time interval/pulse width/duty ratio/frequency ratio/addition calculation 2 50 mVrms: DC < input frequency< 60 MHz
100 mVrms: 60 MHz < input frequency< 120 MHz
10 ns
WE7521 Period, time interval totalize count, quadrature encoder, frequency ratio 4 When hysteresis width in NORMAL and frequency is 1 MHz or less: 1.0 Vpp (typical value)
When hysteresis width is WIDE and frequency is 1 MHz or less: 3.0 Vpp (typical value)
50 ns

Product Home Software Application Download
Testimonials FAQ Demonstration  
Viewing PDF files requires Adobe Reader.
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  WE7000