Low Flow Cut-off

Introduction

Fig.1: Low Flow Cut-off
Fig.1: Low Flow Cut-off

One of the most common applications for differential pressure transmitters is flow measurement. A differential pressure transmitter can be placed across many types of primary flow elements like orifice plates, pitot or venturi tubes to measure flow. Primary flow elements create a pressure drop (square root proportional to flow).

Flow proportional output signals from a differential pressure transmitter are possible through integral square root extraction. The square root function of differential pressure has extremely high gain at low flow rates leading to large output changes representing low changes in flow rate at the bottom end of the measurement range. Output signals can become erratic at low flow rates due to high gain. Host control systems can experience difficulty controlling flow rate based on a highly fluctuating input signal from the square root extracted differential pressure. DPharp differential pressure transmitters have some unique signal conditioning features to eliminate instability at low flow rates.

Application

Flow rates above 20% of maximum flow produce a large square root extracted differential pressure signal for a given change in flow rate. Flow rates around 5% of maximum flow produce a small square root extracted differential pressure signal for a given change in flow rate (See Fig.1). High gain in the low flow rate operating area amplifies any inherent noise or changes in flow rate leading to pressure transmitter output instability.

Solution

Fig2
Fig.2

 

Fig3
Fig.3

DPharp has a software capability to stabilize output signals at the low end of a flow measurement range minimizing erratic output signals. An integral low cut mode features a user programmable transmitter output and set point to change the output to a linearto- pressure (Linear) or zero (Zero) status. The flow rate set point at which an output transition occurs is programmable from 0 to 20% of full scale flow. Fig.2 shows Linear and Zero output modes set at 5 % low cut mode.

Hysteresis is incorporated into the low cut mode such that when the actual flow rate is equal to the low cut set point that output oscillation will not occur. Hysteresis is fixed at a nominal 1% of full scale flow. Fig.3 details how the hysteresis affects the pressure transmitter output.

 

 

Main Features of DPharp

DPharp
DPharp

EJA110A Digital Solution

  • Best-in-class performance
  • ±0.03% Overpressure calibration protection
  • ±0.1% per 5 years long term stability
  • 100:1 turndown
  • ±0.065% accuracy

EJX110A Premium Value

  • ±0.1% per 10 years long term stability
  • 200:1 turndown
  • Best-in-class high accuracy, 0.04%
  • Multi-sensing output
  • Multi-variable transmitter as EJX family line-up
  • Safety as standard (IEC 61508)

產業別

  • 上游

    上游業包含海上和陸上活動,包括井口自動化,分餾,完井和分離,回收和製備地下或水下原油和天然氣。

    當石油被帶到地表時,在運輸之前必須將其分離。在三相分離中,一級和二級分離階段通常分佈有氣體流量,水流量和油流量,氣體的輸送需要管道,並且在輸送之前的上游階段需要進行分餾。液體需要通過罐和管道輸送並處理,這就需要精確的液位測量。

    更多
  • 特種和精細化工

    橫河電機長期以來一直為特種和精細化工的客戶提供服務。我們擁有可為您提供卓越可靠性和靈活性的批量解決方案,同時我們還有在設計批量解決方案時可應對各種複雜要求的行業專家。我們承諾與橫河電機的合作夥伴關系期間,確保您能夠在保證安全和遵從法規的前提下,生產滿足客戶需求的產品。

    更多
  • 石油和天然氣下游

    近年來,石油和天然氣下游產業面臨著越來越多的挑戰。這些挑戰包括待加工原料的特性變化、工業設施及設備的老化、能源成本的上升、缺乏能夠使煉油廠安全有效運行的熟練技術工人,以及市場和客戶的需求不斷變化。
    多年來,橫河與許多下游公司合作,致力於提供應對這些挑戰和問題的工業解決方案。橫河的解決方案幫助工廠投資者盡可能實現最大的盈利能力和工廠內可持續的安全。

     

    更多
  • 管道

    能否正確控制管道和儀表會在性能和盈利方面會產生巨大的差異。橫河擁有專業的技術,可以優化管道解決方案中所有因素的性能,包括壓縮機,泵,閥門及中間存儲和分配設施。

    更多
  • 近海 (FPSO FLNG & FSRU)

    近海的勘探和生產需要在惡劣的條件下最大限度地保障正常運行時間。載人和無人駕駛設施需要可靠的綜合控制和安全系統(ICSS),並且需要具有先進的遠程監控能力。橫河電機擁有先進技術和豐富經驗,可以執行各種規模及自動化程度複雜的離岸項目。

    更多

相關產品&解決方案


置頂