Category Sitemap
Home / Our Businesses / Controllers & Data Acquisition / Products / Signal Conditioners /
JUXTA W Series Signal Conditioners
Product Home · Specifications Contact
Specifications
Construction Front-terminal type
Mounting Method: DIN-rail mounting, rack mounting or wall mounting
Connection Method: M4 screw terminal
External Dimensions: 72×48×127 mm (H×W×D)
Power Requirements: 24 V DC±10% or 85 to 264 V AC

Signal Conditioners
Model Product Name Input Type Output Type Descriptions
WA1A/V Distributor 4 to 20 mA DC, from 2-wire type transmitter DC Voltage or DC Current
WA4A/V Distributor (Non-isolated) 1 to 5 V DC or 4 to 20 mA DC Non-isolated output
WA5A/V
Updated
Distributor (with Square Root Extractor) DC Voltage or DC Current Field configurable
WA0A Output Isolator 1 to 5 V DC DC Current 1500 V AC (1 min.) of withstand voltage for output signal.
WC0A Output Isolator 4 to 20 mA DC 4 to 20 mA or 10 to 50 mA DC
WH0V Output Isolator 1 to 5 V DC DC Voltage
WH1A/V Isolator DC Voltage or DC Current DC Voltage or DC Current Fixed range
WH2A/V
Updated
Isolator (Free Range Type) Free range
Field configurable
WH3A/V Isolator (High Speed Response Type) 15 msec. conversion for 63% response
WHRA/V Isolator (Reverse Output Type) Fixed range
WH4A/V DC Converter (Non-isolated) Non-isolated output
WH5A/V
Updated
Isolator (Square Root Extractor) 1 to 5 V DC Field configurabl
WM1A/V
Updated
Isolator (mV Input Free Range Type) DC mV Signal Field configurable
WR5A/V
Updated
RTD Converter (Free Range Type) Resistance Temperature
Detector (RTD)
DC Voltage or DC Current Field configurable
WRUA/V Cryogenic Temperature Converter Yokogawa J263*B RTD or 4-wire type RTD Field configurable
WT5A/V
Updated
Thermocouple Converter (Free Range Type) Thermocouple DC Voltage or DC Current Field configurable
WS1A/V
Updated
Potentiometer Converter (Free Range Type) Potentiometer resistance (3-wire type) DC Voltage or DC Current Field configurable
WS4A/V Potentiometer Converter (Non-isolated) Non-isolated output
WP1P Pulse Repeater Contact Pulse, Voltage Pulse or Current Pulse Open collector Pulse rate fixed in 1:1
WP4P Pulse Rate Converter Contact Pulse or Voltage Pulse Open collector or Contactless AC switch Field configurable pulse rate (by internal switch)
WQ1A/V Pulse to Analog Converter Contact Pulse, Voltage Pulse or Current Pulse DC Voltage or DC Current Fixed range
WQ2A/V Pulse to Analog Converter (Free Range Type) Free range
Field configurable
WQ0P Analog to Pulse Converter DC Voltage or DC Current Open collector or Contactless AC switch Fixed range
WQ2P Analog to Pulse Converter (Free Range Type) Free range
Field configurable
WB1A/V CT Converter (RMS) AC Current from CT DC Voltage or DC Current R.M.S. conversion
WB2A/V CT Converter (Mean Value) AC Current from C Mean value conversion
WB3A/V AC Current Converter (RMS) AC Current R.M.S. conversion
WG1A/V PT Converter (RMS) AC Voltage from PT R.M.S. conversion
WG3A/V AC Voltage Converter (RMS) AC Voltage R.M.S. conversion
WD1A/V Tachometer Converter AC Voltage from tachometer Mean value conversion
WV1A/V Manual Setter N/A DC Voltage or DC Current With monitoring output
WH1K Limit Alarm DC Voltage or DC Current 2 Relay Contacts
(Form-C)
GLOBAL  
YOKOGAWA

Powered by Ultraseek
·  JUXTA W Series Signal Conditioners
Support
Top of this page