| Model |
Product Name |
Input Type |
Output Type |
Descriptions |
| WA1A/V |
Distributor |
4 to 20 mA DC, from 2-wire type transmitter |
DC Voltage or DC Current |
|
| WA4A/V |
Distributor (Non-isolated) |
1 to 5 V DC or 4 to 20 mA DC |
Non-isolated output |
WA5A/V
Updated |
Distributor (with Square Root Extractor) |
DC Voltage or DC Current |
Field configurable |
| WA0A |
Output Isolator |
1 to 5 V DC |
DC Current |
1500 V AC (1 min.) of withstand voltage for output signal. |
| WC0A |
Output Isolator |
4 to 20 mA DC |
4 to 20 mA or 10 to 50 mA DC |
| WH0V |
Output Isolator |
1 to 5 V DC |
DC Voltage |
| WH1A/V |
Isolator |
DC Voltage or DC Current |
DC Voltage or DC Current |
Fixed range |
WH2A/V
Updated |
Isolator (Free Range Type) |
Free range
Field configurable |
| WH3A/V |
Isolator (High Speed Response Type) |
15 msec. conversion for 63% response |
| WHRA/V |
Isolator (Reverse Output Type) |
Fixed range |
| WH4A/V |
DC Converter (Non-isolated) |
Non-isolated output |
WH5A/V
Updated |
Isolator (Square Root Extractor) |
1 to 5 V DC |
Field configurabl |
WM1A/V
Updated |
Isolator (mV Input Free Range Type) |
DC mV Signal |
Field configurable |
WR5A/V
Updated |
RTD Converter (Free Range Type) |
Resistance Temperature
Detector (RTD) |
DC Voltage or DC Current |
Field configurable |
| WRUA/V |
Cryogenic Temperature Converter |
Yokogawa J263*B RTD or 4-wire type RTD |
Field configurable |
WT5A/V
Updated |
Thermocouple Converter (Free Range Type) |
Thermocouple |
DC Voltage or DC Current |
Field configurable |
WS1A/V
Updated |
Potentiometer Converter (Free Range Type) |
Potentiometer resistance (3-wire type) |
DC Voltage or DC Current |
Field configurable |
| WS4A/V |
Potentiometer Converter (Non-isolated) |
Non-isolated output |
| WP1P |
Pulse Repeater |
Contact Pulse, Voltage Pulse or Current Pulse |
Open collector |
Pulse rate fixed in 1:1 |
| WP4P |
Pulse Rate Converter |
Contact Pulse or Voltage Pulse |
Open collector or Contactless AC switch |
Field configurable pulse rate (by internal switch) |
| WQ1A/V |
Pulse to Analog Converter |
Contact Pulse, Voltage Pulse or Current Pulse |
DC Voltage or DC Current |
Fixed range |
| WQ2A/V |
Pulse to Analog Converter (Free Range Type) |
Free range
Field configurable |
| WQ0P |
Analog to Pulse Converter |
DC Voltage or DC Current |
Open collector or Contactless AC switch |
Fixed range |
| WQ2P |
Analog to Pulse Converter (Free Range Type) |
Free range
Field configurable |
| WB1A/V |
CT Converter (RMS) |
AC Current from CT |
DC Voltage or DC Current |
R.M.S. conversion |
| WB2A/V |
CT Converter (Mean Value) |
AC Current from C |
Mean value conversion |
| WB3A/V |
AC Current Converter (RMS) |
AC Current |
R.M.S. conversion |
| WG1A/V |
PT Converter (RMS) |
AC Voltage from PT |
R.M.S. conversion |
| WG3A/V |
AC Voltage Converter (RMS) |
AC Voltage |
R.M.S. conversion |
| WD1A/V |
Tachometer Converter |
AC Voltage from tachometer |
Mean value conversion |
| WV1A/V |
Manual Setter |
N/A |
DC Voltage or DC Current |
With monitoring output |
| WH1K |
Limit Alarm |
DC Voltage or DC Current |
2 Relay Contacts
(Form-C) |
|