Program Controller UP35A/UP32A

The UP35A is a program controller with available 4 patterns and 40 segments (max.) and multi-channel contact I/O. It also includes a ladder sequence function. The UP32A is a compact program controller with up to 4 patterns and 40 segments available. It also includes a ladder sequence function.

UTAdvanced

Reliability

CSA C22.2 61010-/1
UL61010-1

> Important notice: UTAdvanced UT52A, UP35A parts of Suffix code

Overview

Advanced Control

  • Ladder sequence control
  • Fuzzy logic control

Simplicity

  • Easy-to-read, 14-segment large color LCD display
  • Scrolling text feature for parameters
  • Navigation guide & navigation keys
  • Programmable funciton keys
  • User settable default values
  • Multiple language support (English, Spanish, French, German)
  • Compact design of 65-mm depth

Networking

  • Ethernet (Modbus/TCP)
  • RS-485 (Modbus/RTU, peer to peer, coordinated, PC-Link)
  • Open network (PROFIBUS-DP, CC-Link, DeviceNet)

Reliability

  • 3 year warranty*1
  • RoHS/WEEE
  • NEMA4*2/IP66 front panel

*1: The 3 year warranty extendes 36 months after shipment from our factory.
*2: Hose-down test only

Application Software

Reliability
CSA C22.2 61010-/1
UL61010-1

Details

Resurse

Prezentare generală:

The Japan Steel Works, LTD., Muroran Plant uses the Control and Measurement Station CX2000, UP series program controllers, and UT series digital indicating controllers for operation of its heat treating furnaces.

Industrii:
Prezentare generală:

Performing control while changing the set point temperature moment by moment is called running a program pattern (or simply running a program). Sterilization and pasteurization require maintaining specific temperatures for specific durations. 

In the LL50A setting tool, input -5.1 for the Control Output Lower Limit (OL) and press ENTER to display SD.
No, simply downloading the parameter data does not require valve readjustment. However, if the parameter settings of the main unit are initialized, or the initialization command is sent from the LL50A, the position adjustment information is lost, so ...
You can turn off the heater break alarm by turning the power to the main unit Off / On. The alarm is also canceled when the heater current value returns to the detected value (set value) or higher of the heater break alarm.
Reverse connections are not recommended. It will work even if connected in reverse, but a fuse is built into the L-side (terminal 111), and the original protection function (internal fuse) may not work. To ensure safe use, we recommend connecting the...
Error code ERR33 is displayed if the program pattern already exists in the copy destination. Delete the program pattern in the destination first, then you can copy it from the source. Or select an unused program pattern number and copy it. ...