Continuous Monitoring for Sugar Solution Leaks in Boiler Feed Tanks

下载 (317 KB)

Introduction

Suger Solution Leak Monitoring
Sugar Solution Leak Monitoring 

In the past, the boiler feed tank systems in sugar factories had to be checked several times a day to make sure there were no sugar solution leaks. This was a very laborious process and, as continuous monitoring was not possible, monitoring results were not reliable. When a leak occurred, recovery operations were very costly and time-consuming.

With the FLXA202 and FLXA402 inductive conductivity analyzers, these are now problems of the past: both devices enable stable, continuous monitoring and the quick detection of sugar solution leaks, preventing serious problems from ever developing.

  

Expected Benefits

  • Automatically detect sugar solution leaks in sugar factories
  • Reduces operating costs

Process Overview

In sugar factories, crystallizers and concentrators produce a large amount of steam drain, which is reused as boiler feed water. However, sugar leaked during the boiler feed process can mix into this water. When that happens, the sugar can decompose into an organic acid at high temperatures, thereby decreasing the pH of the water. If the boiler operates with water at a low pH level, it can become corroded. The lowered pH needs to be raised to a normal level by performing a blowdown or the like, and the losses potentially caused by this process are not necessarily small. The sugar solution leak must be quickly detected before a minor problem turns into something much worse. For this reason, continuous monitoring is essential.

Solution Details

Measurement system

2-wire inductive conductivity system

Sensor: ISC40G(J)-GG-T1-☐☐
Transmitter: FLXA202-D-BーD-☐-C5-NN-A-N-LA-☐-NN
Dedicated distributor for transmitter: PH201G-A☐*B

4-wire inductive conductivity system

Sensor: ISC40G(J)-GG-T1-☐☐
Converter: FLXA402-A-B-☐-C5-NN-A2-WR-☐-☐-☐-NN

Field Data

Process conditions

Steam return line of crystallizer outlet

Measurement liquid: steam drain (plus sugar solution)
Monitoring range: 0 - 200 μS/cm
Temperature: approx. 80 °C
Alarm point: 100 µS/cm

(contact output can be used with the FLXA402)

Sugar Solution Leak Condition
Sugar Solution Leak Condition

Utilities

FLXA202 inductive conductivity transmitter

Power supply voltage: 17 - 40 V DC (from distributor)

PH201G distributor

Power supply: 100 V: 20 to130 V DC/80 to 138 V AC, 47 to 63Hz
220 V: 120 to 340 V DC/138 to 264 V AC, 47 to 63 Hz
Power consumption: 24 V DC: approx. 200 mA
100 V AC: approx. 7 VA
220 V AC: approx. 11 VA

FLXA402 inductive conductivity converter

Power supply: 90 to 264 V AC, 50/60 Hz
Power consumption: 35 VA 

Cautions

As the contact output of the PH201G is always magnetically excited, it should be kept closed even when the power is turned off to perform maintenance.

行业

  • 食品和饮料

    在横河电机,我们了解当今的食品和饮料公司在气候变化、消费者需求和全球竞争力增强方面面临着前所未有的挑战。克服这些挑战需要创新的解决方案,需要重点关注生产、资产管理以及食品安全和质量等关键领域。

    更多

相关产品&解决方案

  • 2-Wire Transmitter/Analyzer FLXA202

    The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.

    更多
  • Hot-Tap Holder PR10

    On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable for applications where the sensors must be removed without interrupting or shutting down the process. Without any special tools the PR10 can be retracted safely from the process at pressures up to 5 bar (72 psi). Using the PR10 allows us to place any dissolved oxygen sensor that has a PG13.5 connenction into a retractable assembly.

    更多
  • ISC40/SC42高电导率传感器

    测量水溶液的特定电导率对于确定水中的杂质越来越重要。横河电机设计了一系列精密传感器和仪器,即使在极端条件下也能应对这些测量。

    更多
  • ISC40百分比浓度传感器

    在多种工业应用中,测量或控制该过程的特定化学强度对于优化最终产品的生产非常关键。通过将全浓度溶液与水混合,可以获得特定百分比浓度的溶液。

    更多
  • 电导率传感器

    电导率传感器和电极用于测量过程电导率、电阻率、WIFI、软化水、RO水、百分比浓度、锅炉水排污和TDS。有伸缩式、流通式、浸入式和直插式等多种安装选项。选择合适的电极/传感器对优化测量结果至关重要。

    更多
  • 电导率分析仪

    电导率测量仪、分析仪和变送器用于对电导率、电阻率、WIFI、软化水、RO水、百分比浓度、锅炉水排污和TDS进行连续测量和监测。

    更多

置顶
WeChat QR Code
横河电机(中国)有限公司