Flue Gas Desulfurization

下载 (369 KB)

Introduction

Recently, air pollution legislations such as the Clean Air Act to reduce the amount of air pollution are increasing worldwide. The Clean Air Act address numerous air quality problems. One of these problems is acid rain caused by sulfur dioxide and nitrogen oxide emissions from fossil-fueled power plants and other industrial and transportation sources. Sulfur oxides and nitrogen oxides (NOx) are recognized as harmful pollutants and great efforts are underway to remove these toxic gases. Under emission regulatory requirements and legislation to reduce the emission of these air pollutants, power plants in particular have installed "flue gas desulfurization systems" also known as scrubbers.

Flue Gas Desulfurization

Flue Gas Desulfurization

Application

Wet flue gas desulfurization or scrubber systems are an excellent way of reducing the sulfur dioxide emissions caused by coal combustion boilers. The flue gas discharged from the boiler is fed into the absorber. In the absorber, a mixture of water and pulverized limestone is sprayed on the flue gas. The limestone slurry absorbs the sulfur dioxide (SO2) contained in the flue gas reducing the emission of sulfur. The limestone reacts with the SO2 to produce calcium sulfite. The calcium sulfite then reacts with oxygen and is then finally removed as gypsum. The limestone slurry and gypsum slurry are very abrasive. Magnetic flowmeters are normally used to measure and control the flow of the limestone slurry to the sprayers.

Conventional style PTFE-lined magnetic flowmeters used in such applications normally have a short life expectancy, due to the abrasiveness of the slurry. The use of non-retained liners and electrodes that expose their seal to the process fluid/slurry make the meters prone to fail. Once the liner wears away or the seal around the electrode is eroded, the process fluid can then attack the meter's internals (coils and electrode wiring).

Electrode

Also, the use of electrodes that protrude into the process can create an increase in slurry noise as the limestone or gypsum collide with the electrode. In slurries, noise (voltage) is generated when solid substances collide with the electrode. Conventional electronics cannot distinguish the noise from the true flow signal and thus the flowmeter's output is erratic and the signal is not suitable for control purposes.


If the flow rate is too high, greater than 2 m/sec (7 ft/sec), the limestone can cause increased wear on the liner. Should any of these conditions occur the life of the meter will be greatly decreased.Incorrect installation of the meter can also contribute to problems for magnetic flowmeters. In addition to the typical installation consideration for upstream and downstream straight runs, maintaining the velocity of the slurry within certain limits is also important. If the flow rate is too low, below 1.5 m/sec (5 ft/sec), the solids (limes tone) can fall out of suspension. In a horizontal line this can cause the bottom of the meter to wear out at an excessive rate.

Solution

The ADMAG AXF magnetic flowmeter is an excellent choice for this application. Since Yokogawa uses a retained liner and an insertion style electrode that removes the sealing surface from the process fluid, service life is dramatically increased. The potential for slurry noise due to the limestone and gypsum colliding with the electrode is reduced due to ADMAG's flush electrode design.

ADMAG AXF

ADMAG AXF

In addition, ADMAG's dual-frequency excitation and further optional enhanced dual frequency excitation provides a stable and more accurate measurement than conventional style meters due to its high frequency sampling rate and its ability to filter out slurry noise.

An ideal installation for the measurement of a limestone slurry is to have the flow running up and to have the operating velocity between 1.5 to 3 m/sec (5 to 10 ft/sec). This keeps the limestone suspended in the water and the wear on the liner to a minimum. The use of a metal hat earth ring can also reduce erosion of the liner by protecting the leading edge of the liner. Where these installation recommendations cannot be met, a ceramic-lined meter should be considered. The ADMAG ceramic meter would be well suited for such applications due to the abrasion resistance of its liner and the reduction of slurry noise due to the flush and fused platinum electrode.

Further the ADMAG CA, capacitance type magnetic flowmeter, which is ceramic lined and has no wetted electrodes provide ultimate solutions of abrasion resistant and immune to slurry noise.

ADMAG Notes

  • Molded, mechanically retained PFA liner
  • Flush electrode design
  • No exposed electrode seal
  • (Enhanced) Dual-frequency excitation
  • Excellent slurry performance

行业

  • 化工

    化工厂依靠连续和批量的生产过程,每个生产过程对控制系统都有不同的要求。连续的过程需要一个强大而稳定的控制系统,该系统不能因为自身失效而导致生产线关闭;批量过程的重点在于拥有一个可以灵活调整公式程序的控制系统。两种系统都需要在产品质量记录中进行管理,并且能够执行非常规操作。横河电机凭借广泛的产品组合、经验丰富的系统工程师、遍及全球的销售和服务网络,为每个工厂流程提供解决方案。

    更多
  • 油气下游

    近年来,油气下游产业面临着越来越多的挑战。这些挑战包括待加工原料的特性变化、工艺设施及设备的老化、能源成本的上升、缺乏能够使炼油厂安全有效运行的熟练技术工人,以及市场和客户的需求不断变化。

    多年来,横河与许多下游公司合作,致力于提供应对这些挑战和问题的工业解决方案。横河的VigilantPlant解决方案帮助工厂投资者尽可能实现最大的盈利能力和工厂内可持续的安全。

    更多
  • 火电

    使用煤、石油或天然气作为燃料的火力发电占全世界发电量的大部分。

    更多
  • 特种和精细化工

    横河电机长期以来一直为特种和精细化工的客户提供服务。我们拥有可为您提供卓越可靠性和灵活性的批量解决方案,同时我们还有在设计批量解决方案时可应对各种复杂要求的行业专家。我们承诺与横河电机的合作伙伴关系期间,确保您能够在保证安全和遵从法规的前提下,生产满足客户需求的产品。

    更多
  • 精炼

    在不断变化的市场中,炼油厂不仅是原油加工单位,而且是利润中心。同时,人们强烈意识到炼油厂设施安全性的重要。为了实现盈利、效率及环境保护的长期目标,需要包括计划、调度、管理和控制的总体生产解决方案。凭借在自动化领域多年积累的专业知识,横河可以为您提供经济实惠的完善的整体解决方案,改善操作并使世界更清洁。

    更多

相关产品&解决方案

  • ADMAG AXG系列

    ADMAG TI系列ADMAG AXG可用于工业生产线,如石油天然气/化工/造纸/食品&饮料/采矿&金属等应用。凭借出色的可靠性、操作和维护的便捷性,以及几十年的现场验证经验,AXG可帮助用户增加效益,同时降低总成本。

    更多
  • ADMAG CA系列

    ADMAG CA电磁流量计凭借陶瓷管外部设置的电极板,通过管道电容获取电动势。此外,流量计采用了一种卓越的高频励磁方式,使低电导率流体的噪声明显降低。

    更多
  • 电磁流量计

    横河电机在电磁流量计方面的经验已经有数十年了。我们的电磁流量计为大多数地区的工业用途提供了灵活的配置。

    更多

置顶
WeChat QR Code
横河电机(中国)有限公司