Level measurement is one of the more essential measurements in a process. Incorrect measurements can cause tanks to overflow creating potential safety or environmental problems; or, low levels can cause pump damage. Even wrong intermediate levels can result in an inferior quality product. Whether the application is for monitoring or control, the level measurement needs to be accurate, reliable, and quick.
Which Series is Right for You?
Click the 'Details' Tab above to learn which series is right for your application.
-
EJXC80A, EJAC80E (Differential Pressure Direct Mounted Seal)
Direct Mounted Diaphragm Seal System consists of differential pressure transmitter with single direct mount diaphragm seal.
-
EJXC80A, EJAC80E (Differential / Gauge Pressure Diaphragm Seal)
Diaphragm Seal System consists of differential pressure or gauge pressure transmitter with one or two diaphragm seal.
-
EJXC40A (Digital Remote Sensor)
Digital Remote Sensor (DRS) Transmitter connects two pressure sensors, primary (high-pressure side) and secondary (low-pressure side) in a remote location, with DRS dedicated communication cable to measure differential pressure.
-
EJXC50A, EJAC50E (Gauge Pressure Direct Mounted Seal)
Direct Mounted Diaphragm Seal System consists of gauge pressure transmitter with single direct mount diaphragm seal.
Details
Which Series is Right for You?
Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications.
EJA-E Series | EJX-A Series | |
---|---|---|
Accuracy | ||
± 0.075 of Span | ● | ● |
Stability | ||
± 0.1% of URL per 1 year | ● | ● |
Response Time | ||
120 msec | ● | ● |
Diaphragm seal type | ||
Flush Flanged | ● | ● |
Extended Flange | ● | ● |
Safety Certified | ||
IEC 61508 Certified (SIL 2) | ● | ● |
Multi-Sensing | ||
Differential Pressure | ● | ● |
Static Pressure | ● | ● |
Resources
DP Level transmitter configuration can be very time consuming. Yokogawa DPharp EJA/EJX Pressure transmitters realize reduction in man hours by smart level setup feature.
Yokogawa DPharp EJA/EJX Pressure transmitters do not need frequent re-zeroing due to superior long term stability, it contributes to reduce maintenance time.
Cerchi più informazioni su tecnologia, soluzioni o sulla nostra squadra?