Introduction
Autophagy is the mechanism of the cell that disassembles unnecessary proteins and organelles to recycle or metabolize them. When placed in certain physiological conditions, the cells produce phagophore to cover unnecessary components and form autophagosome. The autophagosome fuses with lysosome (production of autolysosome), and acid hydrolase from lysosome degrades the unnecessary components. Autophagy has been confirmed to be related to cancer and neurodegenerative diseases such as Alzheimer and Parkinson’s disease, and as possessing a physiological function in aging.
The following are the results of experiments using the CQ1 for imaging and the high content analysis software CellPathfinder for analysis. In this experiment, DALGreen-Autophagy Detection (Donjindo Molecular Technologies, Inc.)*1 was used; it penetrates cell membranes and is drawn into autophagosome along with unnecessary components, fusing with lysosome and then increasing fluorescence in the acid environment in autolysosome.
Experiment Procedure
- HeLa cells were cultured in 96-well plates (Greiner #655087) for 24 hours.
- DALGreen – Autophagy Detection was added according to the attached protocol and incubated for 30 minutes.
- The cells were washed in the cultured medium, and then medium were changed to normal medium, autophagy inducer medium (not containing amino acid) and autophagy inhibition medium (Bafilomycin added to the inducer medium at the final concentration of 100nM). Time-lapse imaging using the CQ1 was implemented every 30 min, for 6 hours (object lens magnification of 20x, 4 fields, 6 Z-slices per well), and fluorescence images processed with DALGreen (Ex:405nm/Em:500-550nm) and bright field images were captured.
- Contrast-enhanced Bright Field (CE Bright Field) images*2 were created from the bright field images using the CellPathfinder, and the cells were counted. Granules produced through autophagy were analyzed in the fluorescence images.
Fig. 1: Autophagy detection Fluorescence images of the control (A), autophagy induction (B) and autophagy inhibition (C) 6 hours after changing the medium.
(D) (E) (F): CE Bright Field images of (A), (B) and (C) respectively (Scale bar: 100 µm)
(G): Images (from left) immediately after changing the medium, 3 hours later and 6 hours later (Scale bar: 50 µm).
Time lapse movie : Play
Fig. 2: Autophagy analysis result Merged images of the control (A), autophagy induction (B) and autophagy inhibition (C) 6 hours after changing the medium.
(D) (E) (F): Analyzed images of (A), (B) and (C) respectively (Blue points: centers of recognized cells; Red: recognized regions of autophagy granules) .
(G) (H): Change of count and total area of granules per cell over time. Error bars indicate SE (n=3). (Blue: control, Red: autophagy induction, Green: autophagy inhibition).
The count and total area of granules increased over time only in the autophagy induction.
Results and Discussion
It was confirmed that live cell autophagy can be easily observed using the CQ1 and DALGreen-Autophagy Detection. Also, autophagy was induced in the media not containing amino acid and inhibited by adding Bafilomycin. The CQ1 allows for the observation of changes with time while maintaining the culture environment through the use of its stage heater for the control of temperature and humidity, as well as the concentrations of CO2 and O2 through the combined use of a gas mixer.
*1 Reference: Iwashita et al., Small fluorescent molecules for monitoring autophagic flux, FEBS Lett,2018,592(4),559.
*2 CE Bright Field images
Contrast-enhanced Bright Field (CE Bright Field) images refer to processed images emphasizing the cell thick areas (Fluor type) and contours and details (Phase type), which are suitable for cell recognition without staining.
Our Social Medias
We post our information to the following SNSs. Please follow us.
Follow us | Share our application | |
@Yokogawa_LS | Share on Twitter | |
Yokogawa Life Science | Share on Facebook | |
Yokogawa Life Science | Share on LinkedIn |
Yokogawa's Official Social Media Account List
Related Products & Solutions
-
Benchtop CQ1 Confocal System
The CellVoyager CQ1 provides the highest quality confocal images and extended live-cell imaging in a space-saving benchtop design.
-
CellPathfinder
CellPathfinder is designed for our HCA systems, CQ1 and the CellVoyager series. From beginners to experts, the analysis software lets you quantify subtle physiological changes and even label-free samples with various graph options.
-
CV8000 High-Throughput System
CellVoyager CV8000 is the most advanced high-content screening system. The improved built-in incubator lets you analyze extended live cell responses. With its expandability, 4 cameras, 5 lasers and an optional built-in pipettor, the system permits increasingly complex assay development and high-content screening.
-
High Content Analysis CellVoyager
Our high-content analysis (HCA) systems utilize powerful software to address a wide range of research applications from basic science to complex compound screening.
-
Life Science
Unlocking Life with Precision
Yokogawa’s sensitivity and precision solutions enable rapid and accurate measurements, empowering groundbreaking research, accelerating drug discovery, and optimizing bio-production at scale.