EJXC80A, EJAC80E
Direct Mounted Diaphragm Seal System consists of gauge pressure or differential pressure transmitter with single direct mount diaphragm seal. Suitable for various kinds of pressure measurement.
Key Features
- High performance, high accuracy and high reliability.
- Fast response: 120 ms
About OpreX
OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Field Instruments family that is aligned under the OpreX Measurement category.
Details
Yokogawa’s DPharp digital Pressure transmitters set a new standard for high performance, safety and robustness.
Key Features
- High Accuracy
- Safety as Standard
- 120 msec Response Time
- LPS (Local Parameter Setting)
- Signal Characterizer for the 4 to 20 mA output
Direct Mount Flanged Diaphragm Seal System
- EJXC80A Differential pressure direct mount flanged diaphragm seal system
Measurement Span | Range | ||
---|---|---|---|
M | 1 to 100 kPa | −100 to 100 kPa | |
H | 5 to 500 kPa | −500 to 500 kPa | |
V | Flush type | 0.14 to 14 MPa | −0.5 to 14 MPa |
Extended type | 0.14 to 7 MPa | −0.5 to 7 MPa |
- EJAC80E Differential pressure direct mount flanged diaphragm seal system
Measurement Span | Range | ||
---|---|---|---|
M | 1 to 100 kPa | −100 to 100 kPa | |
H | 5 to 500 kPa | −500 to 500 kPa | |
V | Flush type | 0.14 to 14 MPa | −0.5 to 14 MPa |
Extended type | 0.14 to 7 MPa | −0.5 to 7 MPa |
Item | Specifications |
---|---|
Applicable Products (transmitter) | Differential Pressure Transmitter: EJX110A, EJA110E |
Process connection size |
|
Zasoby
DP Level transmitter configuration can be very time consuming. Yokogawa DPharp EJA/EJX Pressure transmitters realize reduction in man hours by smart level setup feature.
Yokogawa DPharp EJA/EJX Pressure transmitters do not need frequent re-zeroing due to superior long term stability, it contributes to reduce maintenance time.
Differential pressure level measurement has an enemy- temperature. Temperature can have a negative effect on the accuracy of level measurement. This article covers why temperature has this effect and how it can be reduced.
Downloads
Broszury
Instrukcje obsługi
Ogólne specyfikacje
Informacje techniczne
- Functional Safety Manual (730 KB)
- Functional Safety Manual exida Certification (436 KB)
Schematy
- EJXC80A, EJAC80E Diaphragm Seal System, EJX110A, EJA110E with Direct Mount Seal at High Pressure Side (334 KB)
- C20FW Direct Mount Flanged Diaphragm Seal (Flush type) (371 KB)
- C20FE Direct Mount Flanged Diaphragm Seal (Extended type) (352 KB)
- C30SW Direct Mount Hygienic Diaphragm Seal (Flush Type) (237 KB)
- C30SE Direct Mount Hygienic Diaphragm Seal (Extended Type) (255 KB)
- C10FR Flushing Connection Ring (231 KB)
Szukasz dodatkowych informacji na temat naszych pracowników, technologii i rozwiązań?
Kontakt