EJXC80A, EJAC80E (Differential Pressure Direct Mounted Seal)

EJXC80A, EJAC80E
Direct Mounted Diaphragm Seal System consists of gauge pressure or differential pressure transmitter with single direct mount diaphragm seal. Suitable for various kinds of pressure measurement.

Key Features

  • High performance, high accuracy and high reliability.
  • Fast response: 120 ms

About OpreX

OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Field Instruments family that is aligned under the OpreX Measurement category.

Details

Yokogawa’s DPharp digital Pressure transmitters set a new standard for high performance, safety and robustness.

Key Features

  • High Accuracy
  • Safety as Standard
  • 120 msec Response Time
  • LPS (Local Parameter Setting)
  • Signal Characterizer for the 4 to 20 mA output

Direct Mount Flanged Diaphragm Seal System

  • EJXC80A Differential pressure direct mount flanged diaphragm seal system
  Measurement Span Range
M 1 to 100 kPa −100 to 100 kPa
H 5 to 500 kPa −500 to 500 kPa
V Flush type 0.14 to 14 MPa −0.5 to 14 MPa
Extended type 0.14 to 7 MPa −0.5 to 7 MPa

 

  • EJAC80E Differential pressure direct mount flanged diaphragm seal system
  Measurement Span Range
M 1 to 100 kPa −100 to 100 kPa
H 5 to 500 kPa −500 to 500 kPa
V Flush type 0.14 to 14 MPa −0.5 to 14 MPa
Extended type 0.14 to 7 MPa −0.5 to 7 MPa

 

Item Specifications
Applicable Products (transmitter) Differential Pressure Transmitter: EJX110A, EJA110E
Process connection size
  • Flush Flanged Seal
    1 1/2-inch (40 mm), 2-inch (50 mm), 3-inch (80 mm)
  • Extended Flanged Seal
    3-inch (80 mm), 4-inch (100 mm)

 

Zasoby

Noty aplikacyjne
Przegląd:

DP Level transmitter configuration can be very time consuming. Yokogawa DPharp EJA/EJX Pressure transmitters realize reduction in man hours by smart level setup feature.

Przegląd:

Yokogawa DPharp EJA/EJX Pressure transmitters do not need frequent re-zeroing due to superior long term stability, it contributes to reduce maintenance time.

Przegląd:

Differential pressure level measurement has an enemy- temperature. Temperature can have a negative effect on the accuracy of level measurement. This article covers why temperature has this effect and how it can be reduced.

Przemysł:

Downloads

Szukasz dodatkowych informacji na temat naszych pracowników, technologii i rozwiązań?

Kontakt

Targi