pH Measurement for Cobb Control in Pulp & Paper Industry

Introduction

cobb1Paper is used in a broad array of products essential for everyday life, from newspapers, books, magazines, printing, writing papers to cardboard boxes and bags, paper napkins, sanitary tissues etc. We are daily surrounded by paper products.

The most important use of paper is writing. The quality of paper used for printing or writing should be good and it depends on many parameters. One of the parameters is Cobb, which needs to be controlled.

What is Cobb Control?

Cobb control is nothing but the control of quality and binding of pulp in such a fashion that whatever is written by any source such as ink, etc on paper it should not spread as well as leave its impression on back side of the paper.

How is Cobb Variation Minimized?

Cobb variation is minimized by maintaining pH of the pulp in the range of 5-6 pH. Before processing, the raw pulp pH is in the range of 7-8. This should be controlled and brought down to acidic range i.e. 5 to 6 pH. This is very essential for following reasons.

  1. This ensures proper binding of the fiber
  2. Cobb is controlled
  3. Further it also helps in maintaining paper 
machine run ability at head box.

How is Cobb Control Done?

Cobb control is done by addition of Alum (which is in the range of 2-3 pH) and rosin to pulp. When alum and rosin are mixed with pulp after a certain distance pH of the mixture is measured and if it is not in the desired range the transmitter will control the Alum dosing via controller so that pH of the pulp is maintained. Rosin on the other side has no such controlled action. It will be getting dosed to the pulp continuously in a specific quantity. It is the Alum whose dosing is controlled depending upon pH variations.

Application Overview

By installing pH loop in paper industry not only the Cobb control is done but also customer can achieve the following:

  1. 20% saving in Alum consumption
  2. Eliminate corrosion problem in approach flow 
pipelines, pumps and other equipment. This is because if alum dosing is not controlled, there are chances that more Alum is dosed and it can lead to corrosion of pipes and components.

Summary

Measurement points:

After Rosin tank:

cobb2

Typical problems: Cleaning of sensor in such installations

Remedies: Using retractable fitting this optimum level of pH can be achieved by using Yokogawa's 4-wire pH Analyser with suitable retractable fitting and sensor. Our manual retractable fitting PR10 with Titanium ball valve is designed for use in pulp industry where frequent
cleaning of the sensor is required. For cleaning one has to take out pH sensor, close the ball valve so that the sample will not come out, clean the sensor, open the ball valve and then put back the cleaned sensor. The pH sensor will be a combination electrode having double junction electrodes, which provide long time stability and a prolonged lifetime. In our 4-wire pH analyser on 2nd mA output we have PI control facility. The speed of the alum dosing pumps can be controlled as per pH variations with the help of this feature.

Industries

  • Pulp & Paper

    The paper and pulp industry is highly competitive and must meet ever-changing market needs. Yokogawa helps realize energy-efficient plants which are globally sustainable.

    See More

Related Products & Solutions

  • 2-Wire Transmitter/Analyzer FLXA202

    The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.

    See More
  • 4-Wire pH/ORP Analyzer PH450

    The PH450 pH and ORP analyzer is a multivariable analyzer that combines pH with temperature and ORP (Redox) measurement, which can be utilized through different output functions: two mA current outputs, four independent SPDT contact outputs and HART. 

    See More
  • Digital SMART SENCOM™ Adapter, SA11

    Reusable SMART adapter, requiring only the analog sensor to be disposed of when it reaches the end of its lifetime. With the SENCOM 4.0 platform, Yokogawa delivers reduced costs and waste while contributing to its long-term business goals of a sustainable future for all.

    See More
  • Hot-Tap Holder PR10

    On-line measurements often present extra challenges, especially when routine maintenance is required. The PR10 is ideally suitable for applications where the sensors must be removed without interrupting or shutting down the process. Without any special tools the PR10 can be retracted safely from the process at pressures up to 5 bar (72 psi). Using the PR10 allows us to place any dissolved oxygen sensor that has a PG13.5 connenction into a retractable assembly.

    See More
  • Industrial pH/ORP Electrodes

    The heart of a pH measuring loop is the electrode system. Yokogawa has designed a wide range of electrodes to ensure this heart keeps beating under the most severe conditions.

    See More
  • Analyzers

    Process analyzers are used to determine the chemical composition and physical properties of substances used in industrial processes.

    See More
  • pH and ORP Analyzers

    pH and ORP meters, analyzers and transmitters are used for continuous process monitoring of pH and ORP to ensure water/product quality, monitor effluent discharge, batch neutralization, pulp stock, scrubbers, cooling towers, chemical, water/wastewater treatment and many other applications.

    See More
  • pH and ORP Sensors

    pH electrodes and sensors are the sensing portions of a pH measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper pH electrode/sensor selection is critical for optimal measurement results.

    See More

Top