Touch Screen GX10/GX20

Power generation, process automation, and factory automation in manufacturing industries require rigorous, continuous monitoring in the control room. The GX series is Yokogawa's latest recorder offering for industrial automation.

The GX series is an industry-first multi-point touch panel, to improve intuitive and smart operator control. Users can scroll, pan, zoom historical data, and even write freehand messages on its dust-proof and water-proof display. The Yokogawa GX series delivers industry leading reliability and measurement accuracy. Its custom graphics accommodates application or process-specific displays, while a wide range of communication protocols guarantee compatibility with your network architecture. It's simple for operators to view and retrieve past data with automatic email and FTP notifications.

New! Built-in AI function to predict the future
A future pen function that draws a predicted waveform for the future a little ahead.
By setting a future alarm for the predicted waveform, you will be notified in advance of possible future events.
>> Please refer to the related page, AI Product Solutions. 

New!   Supporting FDA 21 CFR Part 11, EU-GMP Annex 11, and data integrity
The advanced security function provides safety to use. With the expansion of the advanced security function option (/AS), it corresponds to US FDA 21 CFR Part 11, EU-GMP Annex 11, and data integrity in accordance with ALCOA +.

>>What is "ALCOA +"?

Smart User Interface

Variety of display functions

  • Standard display screens clearly indicate channel data with units and tags, plus alarm log, message log, and other event log information.
  • Custom Display function (option) lets you place graphic images on screens.

Touch screen for intuitive operation

  • The touch screen provides swipe, pinch in/out, and click and drag controls for fast navigation of common display mode functions.
  • Use "2-point touch" to zoom in or out in the direction of display span.

Supports freehand messages

  • Operators can write a free hand text message directly on the touch screen with a stylus or finger.
     

Smart Architecture

Add I/O modules when you need more channels

  • The fully modular I/O design allows you to build the system with the channels you need today, and expand the unit's capability any time in the future by purchasing and installing additional modules.

Wide-ranging input/output specifications

  • The 10 channel universal input module measures DC volts, thermocouple, RTD, and contact input signals. A 16 channel digital input module and a relay output module are also available.
    • GX90XA Analog input module: DC voltage, DC current, thermocouple, RTD, contact
    • GX90XA-10-V1: High withstand voltage AI module: Max. common mode voltage Double insulation 600V, basic insulation 1000VDC
    • GX90XA-04-H0 High Speed AI Module: DC voltage, DC current, thermocouple, RTD, contact
    • GX90XA-06-R1 4-Wire RTD Module: 4-wire RTD, 4-wire resistance
    • GX90YA Analog output module: Current output (Isolated between channels)
    • GX90XD Digital input module: Remote control input or operation recording
    • GX90YD Digital output module: Alarm output
    • GX90WD Digital input/output module: Remote control input or operation recording/alarm output
    • GX90XP Pulse intput module: Pulse signal data acquisition, integral count
    • GX90UT PID control module: PID control (2 loop)

Front panel door available in white or black

  • Choose the best color for your operating environment.

Multichannel I/O

  • GX10 and GX20 support up to 30 channels and 100 channels of input respectively.
  • Up to 450 inputs available with an expansion unit that provides easy Ethernet connection to the recorder.
     

Smart Functionality

AI Function as standard 

  • Predict the future and simultaneously display from the past to the future, and predict and notify you of the set events by e-mail etc.

PID control

  • Enables PID and program control (up to 20 loops per system)
  • The web application enables remote operation and monitoring from a browser.
  • Various pre-configured control screens and display are available.
  • Setpoint program control function (up to 99 patterns)

Dual interval measurement

  • Users have the ability to choose two different scan intervals on a single GX system.

Direct output to printers

  • You can print out reports and snapshots directly from the GX, without going through a PC.

Convenient report creation function

  • Reports can be created automatically using a spreadsheet template created in Excel. You can also output to a PDF file.

Browser-based real time monitoring *

  • A web browser can be used to fully access the GX using two operating modes— Data and Configuration.

21 CFR Part 11 support (option)

  • Strict security measures and FDA 21 CFR Part11 / EU-GMP Annex 11 / Data integrity support

Easy connection with WT series powermeters (option)

  • Easily acquire and record measured data from power measuring instruments (WT series, power analyzers).

DARWIN compatible functions (Ethernet, RS-422/485, RS-232)

  • Upgrade smoothly from DARWIN data acquisition instruments.

Multi-batch Function (option)

  • Recorder pre-defined channel groups to separate data files with independent start and stop control.

SLMP Communication (Mitsubishi PLC) (option)

  • Protocol function that enables connection from a GX to Mitsubishi Electric PLCs without sequence programs.

OPC-UA Server (option)

  • Data acquired by the GX can be accessed through Ethernet communication from a host system (OPC-UA client).

Supports the aerospace industry's AMS2750/NADCAP for heat treatment applications (option)

  • Calibration correction schedule control function
    Schedule management for periodically executing calibration correction configuration and the like.

Supports the automotive industry's CQI-9 for heat treatment applications (option)

  • Compliant with heat treatment standard CQI-9 adopted by major companies in the automotive industry.


* Notice on Java Plug-in running in Web browser for SMARTDAC+ series

 

An intuitive UI engineered for ease-of-use

Efficiently search for key data

Easily review historical data

Seamless display of historical trends—flick or drag the trend display to scroll through the data, even during measurement.

Efficiently search for key data

Quickly find data using calendars and summary screens

From a calendar, jump to waveforms of a specific date. From the alarm summary, jump to the waveform active during the alarm.

Quickly find data using calendars and summary screens

 

Easily check off trouble spots

Write freehand messages

Immediately clear areas of concern with a hand-written message.

Write freehand messages

You can draw or hand-write on the waveform area using a stylus (standard accessory) or the tip of your finger. You can even select a color and line width. Alternatively, you can select from a list of preset messages.

Save and output image files

Save trend waveforms of interest or screens displayed during alarms as image (PNG) files, and print them out at the same time.

Save and output image files

 

Check waveforms of concern in detail

Display digital values at any location

Move the scale to display the value corresponding to that position as a numeric value. Instantly check maximum/minimum measured values.

Display digital values at any location
[Patent technology]

Ascertain long-duration trends at a glance

All historical trends display

Long-duration trends can be fitted to a single screen for easy viewing.

All historical trends display
All historical trends display

Zoom in/out - time axis and engineering units

The time axis and engineering axis can expanded and compressed using a simple pinch together or apart function

Pinch apart / Pinch together
Pinch apart / Pinch together

 

Create your own screens

Custom display (/CG option)

You can arrange display objects such as trend, numeric, and bar graphs any way you like to create monitor displays that are customized to the environment. Start/stop pumps and perform other operations.

Custom display (/CG option)Custom display (/CG option)

Custom display building software
DAQStudio DXA170

DAQStudio is software for creating custom displays. You can load screens you created onto the GX via Ethernet or external memory media (SD/USB) and display them.

DAQStudio DXA170

 

Variety of display screens

Physical quantities are displayed and recorded on a log scale.

Physical quantities are displayed and recorded on a log scale.

Multi-panel display

You can select from 9 layouts, and save up to 20 configurations. (Multi panel available on the GX20 only)

Multi-panel displayMulti-panel display

Highly flexible and scalable architecture

Modular input/output

Inputs and outputs are modular for easy expandability. The GX multichannel paperless recorder main unit alone provides up to 100 channels (GX20) of measurement.

Modular input/output

 

Wide variety of input/output modules

Select from a wide variety of input/output modules.

Select from a wide variety of input /output modules.

Model Name Measurement/Application Channels
GX90XA-10-U2 Analog input module DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (solid state relay scanner type) 10
GX90XA-10-L1 DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Low withstand voltage solid state relay scanner type) 10
GX90XA-10-T1 DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (electromagnetic relay scanner type) 10
GX90XA-10-C1 DC current (mA) (solid state relay scanner type) 10
GX90XA-10-V1 DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Solid state relay scanner type) 10
GX90XA-04-H0 DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (individual A/D type) 4
GX90XA-06-R1 4-wire RTD, 4-wire resistance (solid state relay scanner type) 6
GX90YA Analog output module Current output 4
GX90XD Digital input module Remote control input or operation recording 16
GX90YD Digital output module Alarm output 6
GX90WD Digital input/output module Remote control input or operation recording/alarm output DI:8/DO:6
GX90XP Pulse input module Pulse signal data acquisition, integral count 10
GX90UT PID control module PID control (2 loop) AI:2/AO:2
DI:8/DO:8

 

Expandable to up to 450 channels (real actual input)

Supports up to 450 channels of measurement. Note that if MATH and communication channels are included, the GX20 large memory type can record on up to 1000 channels. The GX main unit and expandable I/O can both use the same input/output modules.

Expandable to up to 450 channels

You connect directly with a LAN cable without connecting through a hub or repeater.
* You can also connect subunits of the GM Data Acquisition System.

Model Type Max.channels Number of channels by configuration
GX10 Standard 100ch Main unit only 0-30
Main + expandable I/O 0-100
GX20 Standard 100ch Main unit only 0-100
Main + expandable I/O 0-100
Large memory 450ch Main unit only 0-100
Main + expandable I/O 0-450

The number of channels is for analog input only.

Reduce wiring with distributed installation

When the recorder is installed offsite (away from the DUT), you can place the expandable I/O at the site and monitor data without the need for long-distance wiring of thermocouples and other sensors.

Reduce wiring with distributed installation

A full range of network functions and software

Draw predicted future data with AI

AI comes standard on the GX/GP.
No complicated settings. Simply register channels, and you're ready to draw future measured data on those channels.

Future Pen

Use acquired data to predict future data, and display predicted future waveforms along with real time data on the trend monitor. Predicted future waveforms help you identify and deal with likely problems as soon as possible.

  • Max. channels: 10
  • Shortest recording interval: 1 sec.
  • Prediction range: Recording interval x 60 points

* Effective for relatively slowly fluctuating data. Not suitable for rapidly fluctuating data.
* Certain restrictions apply with the future pen function. See the general specifications for details.

Ai standard GX/GP

Future alarms

You can set future alarms based on future data predicted by the future pen. You can check future alarm information in the Future Alarm Summary screen. Also, when a future alarm occurs, notification can be sent by external (digital) output or email. Because the future alarm information also includes the predicted alarm time, you can also identify the urgency.

> Click here for details on AI functions

Future Alarm

Real time remote monitoring from a web browser

Through a Web browser you can monitor the GX in real time and change settings. You can easily build a seamless, low-cost remote monitoring system with no additional software.

Real time monitoring screen

You can view monitor screens in real time that are identical to the trends, digital, and other displays on the GX main unit.

Real time monitoring screen

Enter settings online with a web browser

The setting screen lets you copy AI channel settings and other information to Excel for editing. You can reimport the data into the setting screen after editing.

Enter settings online with a web browser

Dedicated software (free download) is available for loading waveforms and GX settings.

Universal viewer

Data files saved on the GX can be viewed and printed. You can perform statistical computation over an area and export to ASCII, Excel, or other formats.

Universal viewer

Offline setting software

Save settings or transfer them to the GX.

Offline setting software

 

Supports the aerospace industry's AMS2750/NADCAP and the automotive industry's CQI-9 for heat treatment applications

Calibration correction schedule control function (/AH option)

Schedule management for periodically executing calibration correction configuration and the like. The correction factor can be set separately for unit and sensor dependency. For AMS2750, we offer TUS software* that can easily create TUS (temperature distribution test) reports.*.

* For information on TUS software, contact your Yokogawa representative.

GX/GP /AH option

 

Record data in separate files per equipment set

Multi-batch Function (/BT option)

Recorder pre-defined channel groups to separate data files with independent start and stop control. Up to 12 independent batches can be created.

Multi-batch Function (/BT option)

 

PID control function

Control function

Enables PID and program control

  • PID control module
    2-loops per module, up to 20 loops per system/li>
  • Setpoint program control function (/PG option)
    Up to 99 patterns
GX90UT PID control module

Remote operation and monitoring

The web application enables remote operation and monitoring from a browser.

Remote operation and monitoring

Built in control screens and display

Various pre-configured control screens and display are available.

Preset screens for use right out of the box

Seamless integration

Combine and integrate complex legacy control panel into a simple and flexible data acquisition station.

Simple instrumentation

Custom display

Remote operation is possible through screens that are customized for your specific system.

Custom display

High speed measurement (down to 1 ms)

Yokogawa's proprietary A/D converter allows the high speed module to measure data points as fast 1ms.

  • High speed (1 ms) measurement*
  • Proprietary A/D converter

With 1ch per module. At 2 ms, 2 ch per module, and at 5 ms or more, all 4 ch per module.

GX90XA-04-H0 Analog input module (high speed AI)

Max. channels
Model Scan interval
1ms 2ms 10ms
GX10 1ch 5ch 10ch
GX20-1 1ch 5ch 10ch
GX20-2 5ch 25ch 40ch

 

Dual interval measurement with two different scan intervals

Users have the ability to choose two different scan intervals on a single GX/GP system. This allows users the flexibility to measure various types of inputs with two different scan intervals in a single system. For example, this provides for efficient, simultaneous measurement of signals with slow fluctuations such as temperature, and fast-changing signals such as pressure and vibration. Modules can be assigned to measurement groups.

Dual interval measurement with 2 scan intervals.

 

MATH (including reports), and event actions

MATH function (/MT option)

Supports various kinds of math computation, including basic math and functions (square root, logarithms, trigonometry). Write formulas using variables for measured or computed data and save or display the results—this saves time and effort on post-processing. Create hourly, daily, monthly, and other reports with the Report function.

MATH function

Event actions

Ability to assign actions tied to specific events during the operation of the data acquisition station.

Event actions

Report creation and network functions (/MT option)

Report creation and network functions

Provides a variety of convenient networking functions

Modbus/TCP and Modbus/RTU Communications

GX supports Modbus TCP/IP client and server modes for Ethernet communications and Modbus RTU master and slave modes for optional serial communications.

Modbus/TCP (Ethernet connection)

Using the Modbus/TCP and Modbus/RTU functions, you can display and save data from the server and slave devices on the GX.*

* Requires the communication channel (/MC option ).

Modbus client/Modbus master

(Connect up to 16 Modbus/TCP servers, or up to 32 for the GX20-2.)
(Up to 31 Modbus/RTU slaves can be connected.)

Modbus/RTU (RS-422/485 connection)

Using the Modbus/TCP and Modbus/RTU functions, you can acquire GX data from upstream devices.

Modbus server/Modbus slave

 

EtherNet/IP Function (/E1 option)

Using the EtherNet/IP server function, you can access the GX from a PLC or other device to read measurement/computation channels and write to communication input channels (GX10: up to 500ch, GX20-1: up to 300ch, GX20-2: up to 500ch). Communication channel function (/ MC option) is required.

In addition, the following operations required for batch processes can be performed through the PLC using Explicit messages.

  • Recordings / Start and stop calculations
  • Reading and writing batch information
  • Writing messages
  • Reading alarm status
  • Reading/writing of alarm values ​​and alarm types
  • Alarm ACK*
  • Number of simultaneous connections: Up to 10 (Explicit message)
  • Supporting protocols: EIP/PCCC, EIP/native

EtherNet/IP Function

*Only CIP commands are supported for MSG instructions.
*Reading of control alarm status, reading/writing of control alarm values/types, and control alarm ACK are not supported.

Note: Explicit message operation in OMRON PLC has not been confirmed.

 

CC-Link family SLMP communication (/E4 option)

Protocol function that enables connection from a GX to Mitsubishi Electric PLCs without sequencer programs. You can run the GX as an SLMP client, enabling writing of GX measured data to the PLC and writing of PLC data to communication channels.*

*Requires the communication channel function (/MC option).

CC-Link family SLMP communication

 

Powerful tool for instrument performance evaluation testing (/E2 and /MC options)

Highly precise measured data from power measuring instruments (WT series power analyzers) can be acquired without loss of fidelity on the GX, and recorded and displayed alongside the GX's own measured data. This is ideal for performance evaluation testing because you can record instrument power consumption, temperature, and other phenomena simultaneously.

Powerful tool for instrument performance evaluation testing

  • Models that can be connected:
    Yokogawa Test & Measurement Corp.,
    WT series power analyzers,
    WT300/WT300E (command mode WT300), WT500, WT1800/WT1800E (command type WT1800)
  • Max. no. of connections:
    8 (GX10), 16 (GX20)

 

OPC-UA Server (/E3 option)

Data acquired by the GX can be accessed through Ethernet communication from a host system (OPCUA client). Writing from an upstream system to a GX communication channel requires the communication channel function (/MC option).

OPC-UA Server

 

DARWIN-compatible communication

The GX supports DARWIN communication commands. Use your current DARWIN communication programs as-is on the GX.*

* See your dealer or nearest Yokogawa representative for details.

DARWIN-compatible communication

CENTUM/STARDOM communciation package

  • CENTUM: LFS2432, DARWIN/DAQSTATION Communication package (for ALE111 [Ethernet])
  • STARDOM: NT365AJ DARWIN connection package

 

FTP-based file transfer

The FTP client/server functions allow you to easily share and manage data from a centralized file server.

FTP-based file transfer

 

E-mail messaging function

E-mail messaging function

 

Automatic network setup (DHCP) function

Using Dynamic Host Configuration Protocol (DHCP), the GX can automatically acquire the settings it needs (IP address) for network communications from a DHCP server. This makes it easier than ever to install the unit on a plant network.

Automatic network setup (DHCP) function

Time synchronization with network time servers

GX uses SNTP protocol in client mode to acquire time information from a network time-server. This function allows any number of GX units within a facility to have precisely synchronized time; all units will record data with coordinated date and time stamp information. In addition, GX can function as a server, providing time data to other SNTP client units on the network.

Time synchronization with network time servers

Rock-solid hardware and highly secure

Choice of mounting designs

Choice of mounting designs

 

Be confident that recorded data is saved

Measured and calculated data is continuously saved to secure, internal non-volatile memory. At manual or scheduled intervals, the files in memory are copied to the removable media. In addition, the files can be copied and archived to an FTP server.

Be confident that recorded data is saved

Because of the inherent reliability and security of non-volatile memory, the possibility of losing data under any operating condition or power failure event is extremely small.

 

Select file formats according to your application

For increased security, measured data can be saved in binary format. This format is very difficult to decipher or modify in traditional text editors or other programs. To enable easy and direct opening of the data in text editors or spreadsheet programs, choose text format. This allows you to work with your measurement data without dedicated software.

ASCI data display
ASCI data display

Binary data display
Binary data display

 

Security enhancements

Safely sends and receives customer data.

Security enhancements

SSL: An encryption protocol for data sent over TCP/IP networks.

 

Front panel door lock

The front panel door can be locked to prevent mishandling of the power switch or external media.

Front panel door lock

 

Analog front end module

A proprietary A/D converter delivers high speed, high precision data acquisition. (High-speed AI, PID Control module)

Analog front end module

 

Standards supported

Standards supported

Strict security measures
Advanced security function option (/ AS) corresponding to strict requirements for data management

SMARTDAC+ GX /GP/GM advanced security function option (/AS) provides safe and traceable data management in applications such as pharmaceutical manufacturing, biotechnology, health management and medical institutions.
The advanced security function supports the strict requirements of US FDA 21 CFR Part 11, EU-GMP Annex 11 and other associated guidelines for data management.
It also supports data integrity in accordance with ALCOA+ (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) mentioned in PIC/S, WHO, MHRA and FDA guidance documents.

FDA 21 CFR Part 11

What is "ALCOA +"?
It refers to A: attribution, L: legibility, C: simultaneity, O: originality, A: accuracy, C: completeness, C: consistency, E: Persistence, and A: Availability. ALCOA + is a requirement for data integrity guidelines of PIC / S (Pharmaceutical Testing Contract and Pharmaceutical Testing Joint Scheme), WHO (World Health Organization), MHRA (Pharmaceuticals and Drug Regulatory Authority: UK), and FDA (Food and Drug Administration).
 

Secure electronic records

Measured data, settings, and operation logs, are saved to a single encoded binary file. Encoded data in binary format offers a high level of security because it cannot be opened in most text editors.
If the data files are damaged or tampered with, SMARTDAC+ Standard Universal Viewer software will identify the nonconformity and notify the user accordingly.

Security data file transfer

SMARTDAC+ can automatically transfer data to an FTP server. FTPS, which encrypts data transferred via FTP using SSL, is also supported, allowing data files to be transferred safely.

SSL-based encryption

Electronic signature(data record signing) function

Measurement data can be displayed and confirmed on the GX/GP (only the data in the internal memory) or the SMARTDAC+ Standard Universal Viewer software, and an electronic signature can be applied to that data. Three levels of signature are available: operator, supervisor and quality control. The signature along with information such as pass/fail and comments can be saved to the data for review and audit.

*Electronic signature to the GM is possible only from the SMARTDAC+ Standard Software. Electronic signature cannot be applied through GM's web server.

Sign Record

Logical security

Data integrity requires that the right users have access to the right information.
SMARTDAC + can create users with various access privileges.

  • Four main security levels (two separate administrator roles, user and monitor user).
  • Up to 200 persons can be registered.
  • Process owners/ system owners can be given access rights to functionality appropriate to their role.
  • For the password, a minimum string length and a minimum policy complexity can be set.
  • Centralized management of user names and passwords using servers on the network is possible through ActiveDirectory.

Logical Security

Audit trail function

The SMARTDAC+ operation log is saved to a file along with measurement data.
When settings are changed, it is possible to record the reason for the change along with the setting change operation. In addition, checking the details of setting changes from "setting difference operation history" makes greatly reduces the data checking work during audits.

Audit trail function

 

Free dedicated software download

SMARTDAC+ Standard Software is possible to display measurement data, display the operation log, and configure the GX/GP/GM. It is also possible to sign in data using the SMARTDAC+ Standard Universal Viewer.

Universal Viewer software

The Universal Viewer software can display data files in various forms such as waveforms and numeric values. It can display and print not only measurement data but also alarm and message lists and operation logs. With the operation log, a comparison of the settings before the change and those after the change can be displayed, allowing you to check the changes in detail.
It is also possible to sign the data by entering the user name, user ID and password after confirming the measurement data. If the data has already been signed, you can sign at a different level after confirming the signature state on the screen.

Universal viewer

Hardware Configurator software

Hardware Configurator software allows for offline system configuration which can be imported via SD memory or external storage media as well as Ethernet communication. System settings can be printed in a table format to support GX /GP/GM system validation (IQ/OP/PQ).
In addition, a pair of selected setup data files can be compared, and their differences can be displayed and printed in table format.

Offline setting software

 

Validation documentation

Validation documentation (sold separately) is a validation protocol template that simplifies GX/GP/GM and SMARTDAC+ Standard system validation. The document is provided on the Yokogawa website as an MS Word file for easy editing.*

*The validation and document verification are the customer’s responsibility.

GX90XA : Analog input module

GX90XA

Specifications

Model GX90XA
Input type
(Inputs: 10)
DC voltage*1, standardized signal*1, thermocouple*1, RTD*2, DI*1, DC current (with external shunt resistor)*1, DC current*3, resistance*4
DCV 20 mV, 60 mV, 200 mV, 1 V, 2 V, 6 V, 20 V, 50 V, 100 V*5
Standard signal 0.4-2 V, 1-5 V
Resistance 20, 200, 2000 Ω
Thermocouple R, S, B, K, E, J, T, N, W, L, U, W97Re3-W75Re25, KpvsAu7Fe, Platinel 2, PR20-40, NiNiMo, W/WRe26, N(AWG14), XK GOST
RTD Pt100, JPt100, Cu10 GE, Cu10 L&N, Cu10 WEED, Cu10 BAILEY, Cu10 (20°C) α=0.00392, Cu10 (20°C) α=0.00393, Cu25 (0°C) α=0.00425, Cu53 (0°C) α=0.00426035, Cu100 (0°C) α=0.00425, J263B, Ni100 (SAMA), Ni100 (DIN), Ni120, Pt25, Pt50, Pt200 WEED, Cu10 GOST, Cu50 GOST, Cu100 GOST, Pt46 GOST, Pt100 GOST, PT500*4, PT1000*4
DI Level, Contact
DC current 0-20 mA, 4-20 mA
Scan intervals

1/2/5/10/20/50/100/200/500ms, 1/2/5s

Scan interval by type

Suffix code Scan interval
1ms 2ms 5ms 10ms 20ms 50ms 100ms 200ms 500ms 1s 2s 5s
-U2
-C1
-L1
-T1
-H0
-R1
-V1
Power supply and consumption Supplied from main unit, power consumption: 2 W or less
Insulation resistance Between input circuits and internal circuitry: 20 MΩ or greater (at 500 V DC)
Withstand voltage Between the input circuits and the internal circuitry: 3000 VAC for one minute (current input type and low withstand voltage type: 1500 VAC for one minute, high withstand voltage type: 3700 V AC for one minute)
Between analog input channels: 1000 V AC for one minute (excluding b terminals for universal input type) (low withstand voltage type: 400 VAC for one minute, high speed universal type: 3000 V AC for one minute)
Terminal types M3 screw terminals or clamp terminals
Weight Approx. 0.3 kg

*1 Cannot be set for the current input type (type suffix code: -C1) or 4-wire RTD/resistance type (type suffix code: -R1).

*2 Cannot be set for the current input type (type suffix code: -C1), electromagnetic relay type (type suffix code: -T1), low withstand voltage type (type suffix code: -L1) or high withstand voltage type (type suffix code: -V1).

*3 Can only be set with current input type (type suffix code: -C1).

*4 Can only be set with 4-wire RTD/resistance type (type suffix code: -R1).

*5 Can only be set with high speed universal type (type suffix code: -H0).

Model and Suffix Codes

Model Suffix Code Description
GX90XA           Analog input module
Number of channels -04         4 channels (-H0 type only)
-06         6 channels (-R1 type only)
-10         10 channels (-C1, -L1, -U2, -T1, -V1)
Type -C1       Current, scanner type (isolated between channels)
-L1       Low withstand voltage DCV/TC/DI, scanner type (isolated between channels)
-U2       Universal, Solid state relay scanner type (3-wire RTD b-terminal common)
-T1       DCV/TC/DI, Electromagnetic relay scanner type (isolated between channels)
-H0       High speed universal, individual A/D type (isolated between channels)
-R1       4-wire RTD/resistance, scanner type (isolated between channels)
-V1       DCV/TC/DI, high withstand voltage scannertype (Isolated between channels)
- N     Always N
Terminal form -3   Screw terminal (M3)
-C   Clamp terminal
Area N General

GX90YA : Analog output module

GX90YA

Specifications

Model GX90YA
Output type (outputs: 4) Transmission output, manual output
Range 4–20 mA or 0–20 mA
Output update interval 100 msec (shortest)
Load resistance 600 Ω or less
Resolution 0.002%
Power supply and consumption Supplied from main unit, power consumption: 3W or less
Insulation resistance Between output circuits and internal circuitry: 20 MΩ (at 500 VDC)
Between output channel terminals: 500 VDC, 20 MΩ or greater
Withstand voltage Between output circuits and internal circuitry: 1500 AC for one minute
Between output circuits: 500 VAC for one minute
Terminal type M3 screw terminals or clamp terminals
Weight Approximately 0.2 kg

Model and Suffix Codes

Model Suffix Code Description
GX90YA           Analog output module
Number of channels -04         4 channels
Type -C1       Current output (isolated between channels)
- N     Always N
Terminal form -3   Screw terminal (M3)
-C   Clamped terminals
Area N General

GX90XD : Digital input module

GX90XD

Specifications

Model GX90XD
Input types
(Inputs: 16)
  DI or pulse input*1 (Open collector or non-voltage contact)
ON/OFF detection Open collector: Voltage of 0.5 V DC or less when ON, leakage current of 0.5 mA or less when OFF
Non-voltage contact: Resistance of 200 Ω or less when ON, 50 kΩ when OFF
Contact rating 12 V DC, 20 mA or more
Power supply and consumption Supplied from main unit, power consumption: 0.7 W or less
Insulation resistance Between input terminals and internal circuitry: 20 MΩ or greater (at 500 V DC)
Withstand voltage Between input terminals and internal circuitry: 1500 V AC for one minute
Terminal types M3 screw terminals or clamp terminals
Weight Approx. 0.3 kg

Pulse input specifications*1

Counting system The rising edge of the pulse is counted.
Max. pulse period 250Hz (The chattering filter : OFF)
125Hz (The chattering filter : ON)
Minimum detection pulse width Low (close), High (open), both is 2 ms or more
Pulse detection period 1ms
Pulse measurement accuracy ± 1 pulse
Pulse count interval Measurement interval

Filter

The chattering filter can be switched On/Off. (When the chattering filter is off, connect GX/GP so that it is not affected by the noise.)

*1 Integration requires the math function (optional code /MT).

Model and Suffix Codes

Model Suffix Code Description
GX90XD           Digital input module
Number of channels -16         16 channels
Type -11       Open collector/Non-voltage, contact (shared common), Rated 5 VDC
- N     Always N
Terminal form -3   Screw terminal (M3)
-C   Clamp terminal
Area N General

GX90YD : Digital output module

GX90YD

Specifications

Model GX90YD
Output types (outputs: 6) Relay contact (c contact)
Rated load voltage 100 to 240 V AC or 5 to 24 V DC
Max. load voltage/current 264 VAC or 26.4 VDC, 3A/point (resistance load)
Power supply and consumption Supplied from main unit, power consumption: 1.4 W or less
Insulation resistance Between output terminals and internal circuitry: 20 MΩ (at 500 VDC)
Withstand voltage Between output terminals and internal circuitry: 3000 V AC for one minute
Terminal types M3 screw terminals
Weight Approx. 0.3 kg

Model and Suffix Codes

Model Suffix Code Description
GX90YD           Digital output module
Number of channels -06         6 channels
Type -11       Relay, SPDT(NO-C-NC)
- N     Always N
Terminal form -3   Screw terminal (M3)
Area N General

GX90EX : Expansion module

GX90EX

Model and Suffix Codes

Model Suffix Code Description
GX90EX          I/O expansion module
Port -02       2 Ports
Type -TP1     Twisted pair cable
- N   Always N
Area -N Standard accessories

GX90WD : Digital input/output module

GX90WD

Specifications

Model  GX90WD
Input types
(Inputs: 8)
  DI or pulse input*1 (Open collector or non-voltage contact)
ON/OFF detection Open collector : Voltage of 0.5 V DC or less when ON, leakage current of 0.5 mA or less when OFF
Non-voltage contact : Resistance of 200 Ω or less when ON, 50 kΩ when OFF
Contact input rating 12 VDC, 20 mA or more
Output type (outputs: 6)   Relay contact (C contact)
Rated load voltage When connected to the main circuit (fi rst-order power supply), 150 VAC or less
When connected to a circuit derived from the main circuit (second-order power supply), 250 VAC or less (the main circuit is 300 VAC or less and uses an isolated transformer) or 30 VDC or less
Max. load current 2 A (DC)/2 A (AC), resistive load
Power consumption 1.9 W or less
Insulation resistance Between input terminals and internal circuitry: 20 MΩ or greater (at 500 VDC)
Between output terminals and internal circuitry: 20 MΩ or greater (at 500 VDC)
Withstand voltage Between input terminals and internal circuitry: 1500 VAC for one minute
Between output terminals and internal circuitry: 3000 VAC for one minute
Terminal types M3 screw terminals
Weight Approx. 0.3 kg

Each unit (GX/GP main unit and expandable I/O), can use 1 module only.

Pulse input specifications*1

Counting system The rising edge of the pulse is counted.
Max. pulse period 250Hz (The chattering filter : OFF)
125Hz (The chattering filter : ON)
Minimum detection pulse width Low (close), High (open), both is 2 ms or more
Pulse detection period 1ms
Pulse measurement accuracy ± 1 pulse
Pulse count interval Measurement interval

Filter

The chattering filter can be switched On/Off. (When the chattering filter is off, connect GX/GP so that it is not affected by the noise.)

*1 Integration requires the math function (optional code /MT).

Model and Suffix Codes

Model Suffix Code Description
GX90WD           Digital input/output module
Number of channels -0806         8 channel DIs, 6 channel DOs
Type -01       Open collector/non-voltage contact (shared common), rated 5 VDC; Relay, SPDT, (NO-C-NC)
- N     Always N
Terminal form -3   Screw terminal (M3)
Area N General

GX90XP : Pulse input module

GX90XP

Specifications

Model GX90XP
Number of inputs 10
Measurement interval 100 ms (shortest)
Input type Contact (open collector, voltage-free contact), level (5 V logic)
Input range Up to 20 kHz*
* 30 Hz when the chattering filter is in use (On)
Minimum detection pulse width 25 μs*
* 15 ms when the chattering filter is in use (On)
Measurement accuracy Count ± 1 pulse
During integration, the following accuracies are added.
Upon MATH start: +1 measuring period
Upon MATH stop: -1 measuring period
* Integration requires the math function (optional code /MT).
Chattering filter Removes chattering up to 5 ms (can be turned on/off on each channel)
Hysteresis width Approx. 0.2 V
Contact, transistor rating Contact: 15 V DC or higher and 30 mA or higher rating.
Minimum applicable load current 1 mA or less.
Transistor: With the following ratings: Vce > 15 VDC, Ic > 30 mA
Maximum input voltage ±10 V DC
Insulation resistance Between input terminals and internal circuitry:
20 MΩ or greater at 500 V DC
Withstand voltage Between input terminals and internal circuitry: 1500 V AC for 1 minute

 

Model and Suffix Codes

Model Suffix code Description
GX90XP           Pulse input module
Number of channels -10         10 channels
Type -11       DC voltage/open collector/non-voltage contact (shared common), rated 5 VDC
N     Always N
Terminal form -3   Screw terminal (M3)
-C   Clamp terminal
Area N General

GX90UT : PID control module

GX90UT

Specifications

Model GX90UT
Control loops Number of loops 2
Analog input (measured input) Measured points 2
Measurement type DC voltage (DCV)/standardized signal, TC/RTD, DI (LEVEL and non-voltage contact)/DC current (with external shunt resistance)
Scan (control) interval 100 ms or 200 ms (system global setting)
Analog output (control output/transmission output/sensor power supply) Outputs 2
Output type Power supply for current, voltage pulse, or sensors.
Current output: 4-20 mA or 0-20 mA
Voltage pulse output: ON voltage = 12 VDC or more (load resistance 600 Ω or more), OFF voltage = 0.1 VDC or less
Can be used as a sensor power supply (13.0-18.3 VDC)
Digital input (switching the SP, operation mode, etc.) Inputs 8
Input format Non-voltage contact and open collector
Contact rating: 12 VDC or more, 20 mA or more
Digital output (of alarms, events, etc.) Outputs 8
Output format Open collector (sink type)
Output contact capacity Max 24 VDC, 50 mA
Withstand voltage/insulation resistance See PID control module general specifications (GS 04L51B01-31EN)
Terminal type M3 screw terminals
Weight Approximately 0.3kg

Model and Suffix Codes

Model Suffix Code Description
GX90UT           PID control module
Number of loops -02         2 loops
Type -11       8 DIs, 8 DOs
N     Always N
Terminal form -3   Screw terminals (M3)
Area N General

【Support Information】List of Verified SD Memory Cards (SD Cards)

The SD cards of the following manufacturers have been verified for use with SMARTDAC+ GX/GP/GM, μR10000/μR20000 and FX1000. However, please note that Yokogawa does not guarantee normal operation of the SD card when using with products listed below.

【Support Information】List of Verified USB Barcode Reader

The USB barcode reader of the following manufacturers have been verified for use with the SMARTDAC+ GX/GP series, DXAdvanced series. However, please note that Yokogawa does not guarantee normal operation of the USB barcode reader when using with products listed below.

【Support Information】List of RoHS

This is a list of recorder and controller products that support the RoHS (2011/65/EU) directive.

【Support Information】New Legislative Framework (NLF) Conforming Products

This is a list of recorder and controller products that support the New Legislative Framework (NLF.)

【Support Information】Display Language Support List for Recorders

List of languages ​​that can be set for each model.

Przegląd:

Okinawa Cellular Telephone Company has launched an experimental vegetable factory to encourage farmers in the prefecture to enter into that business. The 80 square meter vegetable factory engages in hydroponics, and uses 100% artificial lighting. Located at Nanjo City in the southern part of Okinawa island, the facility holds six levels of beds dedicated to raising greens like romaine and leaf lettuce.

Przegląd:

S&B Sankyo uses the GX20 Paperless Recorder to monitor temperature and pressure in a food processing plant's sterilization process.

Przegląd:

Performing control while changing the set point temperature moment by moment is called running a program pattern (or simply running a program). Sterilization and pasteurization require maintaining specific temperatures for specific durations. 

Przegląd:

DXAdvanced records the clean room temperature, humidity, atmospheric pressure, door openings and closings, etc.

Przegląd:

By using the Multibatch function (an option added with DXAdvanced R3), you can efficiently record data from multiple devices onto a single DXAdvanced.

Przegląd:

The sterilization temperature prior to the filling process is monitored in the field or office. The temperature data is recorded in an external storage medium.

Przegląd:

A computation option computes the "F-value," or sterilizing value for the sterilization process, so that the computation results can be recorded in the form of analog data.

Przegląd:
  • For remote monitoring (of temperature, pressure, and flow volume), installing the MW100 in the plant and DXAdvanced in the office provides for a scalable, pc-free on-site data monitoring solution.
  • You can centralize managment of large quantities of data by automatically transferring acquired data to a FTP server.
Przegląd:

Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.

Przegląd:
  • Universal inputs provide support for thermocouple, RTD, voltage, and a variety of other input signals.
  • Lineup of models for up to 48 inputs.
    Allows multipoint monitoring and recording on a single unit.
  • Easily enables network-based data management. 
    file transfers, Web monitoring, and alarm e-mail
eBooki
AI Product Solution Book Download
(ai product solution book download)
Przegląd:

Multi-touch technologies have rapidly moved from the commercial to the industrial sector where they are being used to enhance data analysis.

Broszury
Instrukcje obsługi
Ogólne specyfikacje
Oprogramowanie
Informacje techniczne
Schematy

Przegląd produktów

    Przegląd:

    Smart user interface, smart architecture, and smart functionality is achieved in the new Yokogawa SMARTDAC+ data acquisition and control product series. The Yokogawa SMARTDAC+ GX and GP are fully integrated measurement, display, and recording platforms equipped with an advanced touch screen operator interface. GX series is a panel-mount design, capable of operating in harsh industrial applications and environments. GP is the portable version of the GX, intended for use in lab and test bench applications.

Instrukcje

Szukasz dodatkowych informacji na temat naszych pracowników, technologii i rozwiązań?


Kontakt
 
Targi