Are the FC800D (Non-reagent Type Free Available Chlorine Sensor Unit) and the RC800D (Reagent Type Residual Chlorine Sensor Unit) suitable for outdoor installation and having any anti corrosive coating for outdoor environment?

The FC800D and the RC800D are not suitable for outdoor installation. Strongly recommend installing inside because of pump structure. If you want to install outside, a separate rainproof cover is required and take care install place environment (no corrosive gases). For example, a roof to avoid direct sunshine and rain is required.

Kapcsolódó termékek és megoldások

  • Liquid Analyzer for Turbidity and Chlorine FLXA402T

    The FLXA402T is the next-generation analyzer for the Turbidity detector and Chlorine sensor. The FLXA402T can connect up to two sensors of Turbidity, Chlorine, pH, and Conductivity, with digital communications availability.

  • Reagent Type Residual Chlorine Sensor Unit RC800D

    The RC800D is a next-generation digital Turbidity analyzer and connect to FLXA402T. The RC800D can measure free chlorine or residual chlorine (total chlorine). It is suitable for free chlorine measurement under challenging and residual chlorine measurement.

  • Turbidity/Chlorine SMART Sensor Platform

    SENCOM 4.0 technology platform gives you more insight with reliable measurement by digital communication. This has been extended to Turbidity and Chorine measurement technologies.