Utilities Systems On-Line Optimization and Monitoring: Experiences from the Real World

Letöltés (158 KB)

Abstract

Utilities systems at oil refineries and other large industrial complexes such as pulp and paper mills or chemical plants are very big energy users that have many degrees of freedom. Manipulating these degrees of freedom with the advice of a cost based optimization program usually can result in significant savings in operating costs with small investment needs.

This is particularly important within the electrical deregulation context. Since the electrical system is the main economic trade-off with a steam system, electrical deregulation provides many new challenges in order to operate the combined systems at the minimum overall cost.

This paper will not describe just all the features of the software or fully explain on-line optimization technology. The objective of this work is to present some interesting facts and lessons from the experience of implementing a cost based optimization program at thirty oil refineries and petrochemical complexes, around the world, since 1997. This paper will focus on the key optimization variables and constraints in steam system optimization, how they should be handled and how the human and organizational aspects can be addressed.

Several of the key optimization problems found in a typical oil refinery steam system such as boilers, extraction-condensing turbines, co-generation and turbine/motors spare drivers are discussed and how those problems can be handled properly is described.

Keywords: Energy Optimization, Process monitoring, Utilities systems, On-Line Optimization

1. Introduction

Refineries and petrochemical plants usually operate large and complex utilities systems. For example, they utilize different kind of fuels, several cogeneration units, many steam pressure levels, different kind of consumers and there are emission limits to be observed. 

These complex utilities systems have several degrees of freedom. Manipulating these degrees of freedom with a cost based optimisation program usually can result in significant savings in operating costs. This is particularly important within current deregulated electrical markets. Since the electrical system poses one of the main economic trade-offs with a steam system, electrical deregulation provides many new challenges to operate the overall combined system at minimum cost.

Other important aspect is that utilities systems are continuously evolving (there are frequent changes) and also, sometimes there is a lack of sensors that need to be addressed properly.
Furthermore, utilities systems have several constraints coming usually from the operations side. For example, maximum flows and steam cushions.

Finally it is important to mention the difficulties that exist in the coordination among plant areas. In large complexes, operators are generally not concerned about global energy costs reductions but only about the Unit(s) under his/her responsibility.

All the items mentioned above have been successfully addressed in more than 30 industrial complexes, since 1997. The purpose of this paper is to comment some facts and lessons learned during the implementation of the on line technology utilized to reduce energy costs. Since the availability of this kind of systems is recent, there is a lack of articles explaining these aspects.

This paper will not focus on software features, on-line optimization technology or detail economic results, which have already been reported (Ruiz et al., 2004). Instead this paper will initially review optimization and constrained variables explaining some optimization examples. Finally, some human and organizational aspects are commented.

2. Optimization Variables

Optimization variables are those variables where you have a relatively free choice on what that value might be. For example, the steam rate at which a particular boiler operates is a free choice as long as the total steam production is satisfied, thus each boiler flow can be optimized such that the most efficient boilers production is maximized. There are two kinds of optimization variables that can be handled when optimizing a steam system.

  • Continuous variables, such as steam production from a fired boiler or steam flow through a steam driven turbogenerator. It is also important to determine if the unit should be shutdown recognizing its minimum operating limit.

  • Discrete variables, where the optimizer has to basically decide if a particular piece of equipment will operate or not. The most common occurrence of this kind of optimization in refinery steam system is spared pump optimization where you have to choose which of two pumps to operate, one of which is driven by a steam turbine and the other by an electrical motor.

3. Constrained Variables


Constrained variables are those variables that cannot be freely chosen by the optimizer but must be limited for practical operation. There are two kinds of constraints in steam systems optimization:

  • Direct Equipment Constraints. An example of a direct equipment constraint is a turbogenerator power output. In a turbogenerator you may optimize the steam flows through the generator within specified flow limits but there will also be a maximum power production limit.
  • Abstract Constraints. An abstract constraint is one where the variable is not directly measured in the system or a constraint that is not a function of a single piece of equipment. An example of this type of constraint is steam cushion (or excess steam production capacity). Steam cushion is a measure of the excess capacity in the system. If this kind of constraint were not utilized then an optimizer would usually recommend that the absolute minimum number of steam producers be operated. This is unsafe because the failure of one of the units could shutdown the entire facility.

4. Optimization Examples

This section will describe and discuss several of the important optimization issues found in refinery steam systems. The SQP (Successive Quadratic Programming) optimizer from Lasdon at the University of Texas at Austin (Fan et al., 1998) is used for a great variety of optimizations although it has been significantly tuned and customized for steam system optimization where there are many integer decision variables. 
4.1 Boiler Optimization 
When optimizing dual fuel boilers (boilers burning different fuels, for example fuel oil and fuel gas, at the same time) it is important to capture the following factors in the model:

  • An on-line line method of measuring efficiency.
  • A method that independently measures the efficiency of each fuel.
  • Accurate costs of the respective fuels.
  • A constraint that accurately limits the total consumption of the respective fuels. 
These limits may be specified by a "have to burn or fuel gas" limit on the lower limit 
and an emission limit on maximum limit.

These factors are important to capture because dual fuel optimizations are not just controlled by the relative boiler efficiencies but also by the costs of the fuels. They are limited by real constraints in the refinery, which specify that so much of a particular fuel must be burned in the refinery because it is produced as a by-product in the refinery and it cannot be sold, so it must be burned. In the European Union and US refineries, this is typically a fuel gas constraint. There may also be a total limit on the cheap internal fuel source as well. The intersection of all these variables provides a very complex optimization that can have very profound economics.

4.2 Steam Production Cushion

When a boiler optimization allows boilers to shut down you must deal with a constraint on the steam production spare capacity (sometimes known as steam cushion). If you don't deal with this an optimizer will tend to aggressively shutdown boilers until you will have very little spare capacity. This may be the minimum operating cost method to operate the steam system but it is not operationally robust. Without some spare capacity built into the system, a small steam failure could cascade into an entire facility shutdown. Underneath we will see how to deal with the steam production cushion constraint.


Here is how to select values for the minimum of the Total Spare Capacity constraint.

  • This number is basically an insurance policy. The larger the number, the safer the 
operation. Higher values, however, cost money because it makes you run more equipment then absolutely necessary and typically there are large savings from shutting down your most inefficient steam producers.
  • A value of 0.0 indicates no spare capacity. If any boiler trips you cannot supply the steam required by the plant.
  • A conservative number to use is the maximum capacity of the largest steam generator on-line. Then, if your largest generator fails, you will be insured that you have enough spare capacity on-line to service the facility.

4.3 Extraction/Condensing Drive Turbines


Optimizing Extraction/Condensing drive turbines is very common especially in ethylene plants. The compressor drives are typically > 10,000 HP. On a drive turbine the mechanical power of the turbine must remain constant (the process is expecting a constant power output). Figure 1 shows an example: A single condensing extraction turbine is modelled as two separate turbines (one from throttle pressure to the extraction pressure and one from the extraction to vacuum pressure).

 

escape1

The accumulator component on the far right calculates the total power from the drive turbine. The constraint above it is an equality constraint on mechanical power. This insures that the mechanical power of the unit remains constant at all times during optimization. The correct mechanical power is determined from the simulation results. In many turbine optimizations like this there are two degrees of freedom to optimize but we know all three flows. Selecting which flows to optimize is usually not important for the optimization. In this case we selected the optimization of the high-pressure turbine throttle flow and the low-pressure turbine exhaust flow. The extraction steam is determined by difference and is limited within its operating limits with the constraint block.


It is very important on condensing turbines like this on to know the surface condenser pressure accurately. The amount of power produced in the low-pressure section of the turbine is extremely sensitive to this number.

Good efficiency curves are also important to have, especially if there are multiple, parallel drives turbines in the system.

4.4 Spared Pump Optimization

Spared Pump optimizations are mixed integer optimizations problems where you must decide which pump to operate for a predetermined process need. The simple and most typical cases is where you have two identical spared drives, one driven by a steam turbine and one driven by a electric motor and you are trying to select the least cost option. This will not be described here. A more complicated case that will be described is when you have several drives, not necessarily the same size, in a shared service and you have to choose the optimal set of drives to operate. First some general comments about this problem:

  • The drives optimized typically will not be very large (> 100 HP but < 1000 HP) because large process driver like a compressor are two expensive to spare.
  • There will be lots of drives to optimize. An older refinery that has small turbine drives might have several hundred in the plant.
  • The turbine efficiencies will be pretty low (in the order of 35% isentropic efficiency) and be very hard to determine because of the size of the turbines
  • The process will dictate how many drives to operate and the optimizer will only need to select the correct ones.

4.5 Cooling Tower Drives

Example 
Figure 2 shows an example of a set of cooling tower pump drives. There are four 500 HP pumps. One is driven by a high pressure to medium pressure back pressure turbine, one by a high pressure to condensing turbine and two by motors. Currently, three of the pumps are running (the two turbines and one motor). The optimizer can manipulate the pumps but must maintain three in operation.

 

escape2

Optimizers are connected to each of the drives. These optimizer icons instruct the overall site optimizer to determine if the respective pumps operate.
The icon with an A inside, on the right, represents an optimization group accumulator. It is a special kind of accumulator that adds up the mechanical power of each of the drives and then controls the total power during optimization. It does the following:

  • Based on its specification, it specifies the mechanical power for each drive, the optimizer limits and the constraint limits connected to it
  • It also has the built in intelligence to simplify the optimization. For example if all the drives in a group were operating it would make the optimizers unavailable because there are no options. You must run all drives.
  • The constraint hooked to the accumulator is either an equality or a minimum constraint on the total mechanical power of all operating pumps. In other words, it requires the optimizer to maintain at least as much total mechanical power from all pumps at the end of the optimization as current operation requires.

5. Implementation Aspects

The most important sensors to implement in the system are those involved directly in optimization, such as boiler flows, letdown and turbo generators flows. Important sensors are those which provide data to the model that is not changed by optimization. Less important are those sensors only utilized for monitoring and that do not participate in the modelling.

Pump status is often a manual entry, unless where it is possible to determine the pump status automatically especially for pumps directly involved in optimization. The status can be inferred from many sources (RPM, flow or standby status).


It is important to emphasize the high involvement and motivation of plant operators right from the beginning of the implementation project. The complete set of optimization recommendations must be taken into account. Options that cannot be implemented in practice are removed during modelling phase.

Coordination among plant areas in order to implement the proposed optimization recommendations is also a critical issue, so management involvement is crucial. The robustness of the tool has helped operators gain confidence in the system.


Final user's acceptance and widespread use, for both engineers and operators, is one of the key issues for an implementation to be considered successful.

6. Conclusions

In this paper, some key optimization problems from experience of implementing a cost based optimization program at oil refineries and petrochemical complexes have been presented.


Typical scenarios at oil refinery steam system such as boilers, extraction-condensing turbines, co-generation and turbine/motors spare drivers have been discussed and how those problems can be handled properly is described.

Finally, some implementation aspects have been mentioned.

References 


1. Fan, Y., S. Sarkar and L. Lasdon, 1998, Experiments with Sucessive Quadratic Programming Algorithms, Journal of Optimization Theory and Applications 56, 3.

2. 
Nelson, D., S. Delk and G. Roseme, 2000, Using Visual MESA to Optimize Refinery Steam Systems, AIChE 2000 Spring Meeting, Session T9013.

3. Ruiz, D., C. Ruiz, D. Nelson, G. Roseme, M. Lázaro and M. Sartaguda, 2004, Energy Costs Reduction By Using and On line Utilities Optimization Tool, ERTC Computing 2004.

Iparágak

  • Finomítás

    In the ever changing marketplace, refineries are seen not only as crude processing units but also as profit centers. At the same time, there is a keen awareness of the need for safety at such facilities. A total production solution that encompasses planning, scheduling, management, and control is required to achieve long-term goals for profitability, efficiency, and environmental protection. With years of expertise in the automation field, Yokogawa can bring you affordable total solutions for improved operability and a cleaner world.

    Továbbiak megtekintése
  • Olaj és gáz feldolgozói ágazat

    The oil & gas downstream industry has been facing an increasing number of challenges in recent years. These include the changing characteristics of the feedstock to be processed, aging of process facilities and equipment, rising cost of energy, lack of skilled plant operators who can run a refinery safely and efficiently, and the ever-changing requirements from both the market and the customer.

    Over the years, Yokogawa has partnered with many downstream companies to provide industrial solutions focused on solving these challenges and problems. Yokogawa's VigilantPlant solutions have helped plant owners to achieve maximum profitability and sustainable safety within their plants.

    Továbbiak megtekintése
  • Petrolkémiai

    Petrochemical companies’ needs are extremely diverse. To come out ahead in today’s highly competitive marketplace, producers are striving to improve quality and productivity. Yokogawa provides tailor-made solutions for these needs based on its long and wide-ranging experience in this field.

    Továbbiak megtekintése
  • Vegyi

    Chemical plants rely on continuous and batch production processes, each posing different requirements for a control system. A continuous process calls for a robust and stable control system that will not fail and cause the shutdown of a production line, whereas the emphasis with a batch process is on having a control system that allows great flexibility in making adjustments to formulas, procedures, and the like. Both kinds of systems need to be managed in available quality history of product, and to be able to execute non-routine operations. With its extensive product portfolio, experienced systems engineers, and global sales and service network, Yokogawa has a solution for every plant process.

    Továbbiak megtekintése

Tetejére