Introduction
Hot Blast Stove Process |
Measurement of O2 Concentration in Hot Blast Stoves Essential to Improving Combustion Efficiency
In a hot blast stove, the by-product gas produced in a coke oven is burned to preheat the air blast for the blast furnace. To improve the combustion efficiency and conserve energy in a hot blast stove, it is essential to be able to control combustion by measuring and adjusting the oxygen concentration in the exhaust gases.
The ZR22G/ZR802G Direct In-Situ Zirconia Oxygen Analyzer is ideally suited for combustion control in hot blast stoves. It utilizes a long-life sensor.
Expected Benefits
- Improves combustion efficiency in hot blast stoves
- Ensures stable, continuous oxygen measurement
- Reduces operating costs
- Minimizes the need for equipment replacement
Process Overview
The temperature of the hot blast used in blast furnaces has been increasing every year and currently stands at around 1300°C. Under such circumstances efficient operation is achieved by such measures as increasing the calorie value of fuel gas, replacing the hot blast furnace more frequently, and recovering waste heat from gas. To further improve combustion efficiency and save energy, measurement of the oxygen concentration in exhaust gases is required.
Solution Details
Field Data
Process Conditions
Measurement: | 20 to 350 ℃ |
---|---|
Pressure point: | Duct |
Temperature: | 3.5 to 10 kPa |
Dust: | 50 mg/Nm3 |
Fuel: | Gas |
Measurement System
Detector: | ZR22G-015-S-Q-E-☐-☐-E-A /CV/Z |
---|---|
Z: | Glove box option |
Converter: | ZR802G-☐-☐-N-N /☐ |
Flow setting unit: | ZA8F-☐*C |
Pressure regulator: | G7013XF or G7014XF |
Case for calibration gas cylinder: | E7044KF |
Note: the calibration gas cylinder must be purchased locally
Utilities
Rated voltage: 100 to 240 V AC
Rated frequency: 50/60 Hz
Power consumption: 330 VA (Max. 800 VA)
Instrument air (reference gas) pressure: 300 to 700 kPa
Notes
- The detector is installed in a glove box to reduce the sample gas pressure.
- When more than three detectors are installed, it is recommended that the AV550G Averaging Converter be used instead of the ZR802G converter. The AV550G accepts signals from up to eight detectors.
Industrien
-
Iron & Steel
In the iron and steel industry, it is crucial to improve the quality of not only products but also manufacturing and operation technologies, as well as to address environmental and energy-efficiency issues. Yokogawa helps customers to create the ideal plant and evolves with them for mutual growth.
Zugehörige Produkte & Lösungen
-
Mehrkanaliges Sauerstoffanalysensystem ZR22/AV550G | Getrennte Messung
Das mehrkanalige Sauerstoffanalysensystem AV550G gestattet eine Messung mit bis zu 8 ZR22-Sonden gleichzeitig. Dank des In-situ-Messverfahrens der ZR-Sonden ist für den Betrieb keinerlei Prozesskonditionierung oder Probenahme erforderlich. Dieses Merkmal sorgt für geschmälerte Wartungskosten und deutlich schnellere Ansprechzeiten der Messsonden bei Prozessänderungen.
-
Zirkonia-Sauerstoff-/Feuchtigkeitsanalysator ZR22G, ZR802G
Dieser Analysator zur Messung der Sauerstoffkonzentration und Luftfeuchtigkeit bei hohen Temperaturen besteht aus einem Detektor ZR22G, der mit einem langlebigen und äußerst zuverlässigen Zirkonia-Sensor ausgestattet ist, und einem Messumformer ZR802G, der über digitale Kommunikations- und Datenprotokollierungsfunktionen verfügt.
Messungen mit ZR22G und ZR802G sind direkt und kontinuierlich ohne Probenahmegerät möglich. Die Geräte sind besonders wartungsfreundlich ausgelegt. Durch eine umfangreiche Selbstdiagnose der Sensorverschlechterung (ohne Einsatz von Kalibriergas) und der Möglichkeit des Austausches des Heizelements vor Ort können effektiv Betriebskosten eingespart werden. -
Sauerstoffanalysatoren
Sauerstoffanalysatoren liefern wertvolle Messwerte, beispielsweise für die Regelung von Verbrennungsprozessen, die Einhaltung der Prozessqualität, die Gewährleistung der Prozesssicherheit und Emissionseinhaltung.