Application
Saturated steam measurement for massflow rate
Requirements
Need to improve the current unstable measurement of steam flow rate.
Besides stable measurement, mass flow rate needs to be confirmed at this measuring point but minimize the number of additional measurement points.
Process Condition :
Size : 50 mm
Fluid : Saturated Steam ; 155 °C, 5.3 kg/cm2 abs
Flowrate : 0 - 1500 m3/h

Proposal
digitalYEWFLO Multi-Variable type can measure flow rate and flow temperature in real time. Temperature fluctuation is simultaneously followed for the output.
This enables high accuracy measurement with temperature offset calculation by steam table, and limits the effect of flow change and boiler oscillation.
Multi-Variable Type
- The shedder bar, which is strong enough to be used as a thermo-well, incorporates a RTD sensor (Pt1000, Class A) for temperature measurement.
- Mass flow rate is calculated based on measured temperature.
- A high level of safety is assured without the expense or installation of a temperature sensor, and additional process connection is not required.

Comparison test DATA of saturated steam measurement
digitalYEWFLO vs YEWFLO (general type) + Temperature input + Pressure input
Beneath data shows the equality of output signal from “digitalYEWFLO Multi-Variable type” and “mass flow computer, receiving the data from digitalYEWFLO(General type), temperature sensor and pressure gauge”.

digitalYEWFLO always output the optimal vortex signal with making full use of the latest Digital signal processing technology, and minimize the effect of fluctuation or vibration noise coming from boiler.
Advantage
digitalYEWFLO Multi-Variable type contributes to cost down, save-energy, and production efficiency of Saturated Steam measurement.

Productos y Soluciones Relacionadas
-
digitalYEWFLO Vortex Flowmeter
Yokogawa's vortex flowmeters are long-lasting and robust, offering field-proven sensor technology and high reliability to deliver improvements in plant efficiency and reduce OPEX.