Gas Density Meter Applications: Faster Hydrogen Concentration Monitoring

Fast, Simple, and Low-Cost Hydrogen Measurement

General H2O electrolysis process
General H2O electrolysis process

 

Measuring hydrogen concentration in a typical H2O electrolysis process has the following challenges:

(1) Conventional thermal conductivity meters and alloy thin film meters; Slow response, tens of seconds to 60 seconds
(2) The anode side need to multiple pretreatments for water separation and dehumidification.

In H2O electrolysis plants that produce hydrogen, cross-leakage to the anode and cathode sides due to membrane degradation is an issue for safety management, and the inability to achieve a fast response in general hydrogen concentration measurement is a major issue for safety monitoring.

Since the gas components of the H2O electrolysis process are hydrogen and oxygen, it is possible to estimate the gas concentration by gas density. The applicability of gas density meters in hydrogen concentration measurement is introduced in this document.

Fig. 3 Schematic diagram of hydrogen measurement
Fig. 3 Schematic diagram of hydrogen measurement

 

Advantages of Using a Gas Density Meter for Hydrogen Measurement

Not only the analyzer's fast response but also pre-processing can be simplified, achieving overall fast response

  1. Simplified Plant Design
    simple pre-processing contributes to the simplification plant design
  2. Fast Response
    The gas density meter is faster than conventional ones

 

Product Details

Gas Density Meter Detector
GD80
Gas Density Meter Detector

GD802G Gas Density Meter Converter
GD802G
Gas Density Meter Converter

 

Principle

Two pairs of piezoelectric elements for drive and detection are attached on four points of a thin-wall cylindrical resonator. A platinum temperature sensor is mounted to the density sensor.

The sample gas from inlet passes over the outside of the thin-walled cylindrical resonator and is exhausted at the gas outlet.

Fig. 4 Detector structure
Fig. 4 Detector structure

 

Gas Density Meter Specifications

Sample Gas Conditions -Sample Gas: All gases except for corrosive gases (Contact Yokogawa for details.)
-Temperature: -10 to 60℃ (No condensation)
-Flow Rate: 0.1 to 1 L/min
-Pressure: 50 kPa to 600 kPa abs.
Principle Multi-mode oscillation technology
Performance Specification -Range: Concentration: 0 to 100 vol% 
-Minimum Range: Equivalent to 0.100 kg/m³ density
-90% Response Time: Approx. 5 s (Time required for the reading to reach 90% of its final value after the indicated value begins to change (at a gas flow rate of 0.6 L/min)).
-Linearity: ± 1% 
-Repeatability: ±0.5% or concentration equivalent to ±0.001   kg/m³ density  (Whichever is greater. )    
-Zero / Span Drift: Equivalent to ±0.003 kg/m³ density/month (Provided that the detector, converter, and pressure transmitter are not affected by ambient temperature.)

Gerelateerde producten & oplossingen

  • Gas Density Meter GD80, GD802G, GD802S

    Fast-response gas density measurement for safe and stable operation. More than density, monitor gas concentration, molecular weight, specific gravity, hydrogen purity, and replacement concentration.

  • Gas Density/Hydrogen Purity Analyzer

    Gas density analyzers and detectors provide continuous measurement of gas density as well as several other valuable parameters, including specific gravity and percent concentration.

  • In-Situ Gas Analyzer TDLS8000

    Yokogawa’s new TDLS™8000 houses all of the industry’s leading features in one robust device. The platform design is for in situ measurements which negate the need for sample extraction and conditioning.