The ADMAG Total Insight (TI) series ADMAG AXW adopts the "Total Insight" concept and totally support the product life cycle.
ADMAG AXW magnetic flowmeter is a high-quality and highly reliable product developed based on years of experience and achievement, such as enhancement of application by our proprietary dual frequency excitation method.
Certified to SIL2 complied with functional safety standard IEC 61508, and can be used in safety instrumented systems up to SIL2 in simplex configuration and SIL3 in redundant configuration.
ADMAG AXW is ideal for general industrial process lines and water supply/sewage applications.
With outstanding reliability and ease of operation and maintenance, developed on decades of field-proven experience, ADMAG AXW will increase your benefits while reducing total cost of ownership.
About OpreX
OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Field Instruments family that is aligned under the OpreX Measurement category.
Details
Specifications & Functions
Please refer to General Specifications in detail.
Remote Type | Integral Type | ||
---|---|---|---|
AXG1A High Grade Transmitter | AXW4A Transmitter | AXW Integral Type | |
Accuracy (Reading Value) |
[Sensor Combination] - AXW: ± 0.35 % |
[Sensor Combination] - AXW: ± 0.35 % |
± 0.35 % |
Size | [Sensor Combination] - AXW: 25 to 1800 mm |
[Sensor Combination] - AXW: 25 to 1000 mm |
25 to 1000 mm |
Use | [Tansmitter] - General Purpose [Sensor Combination] - General Purpose - Explosion Protection - Submersible |
[Tansmitter] - General Purpose - Explosion Protection [Sensor Combination] - General Purpose - Explosion Protection - Submersible |
General Purpose Explosion Protection |
Explosion Protection Use | IECEx, ATEX, Korea, Brazil (INMETRO), EAC * Transmitter is usable only in the safety area. |
IECEx, ATEX, Korea, Brazil (INMETRO), EAC | |
Liner Material | PTFE, Polyurethane, Natural Soft Rubber, Natural Hard Rubber | ||
Communication Protocols | HART 7, BRAIN | HART 7, BRAIN, Modbus FOUNDATION Fieldbus PROFIBUS PA EtherNet / IP |
|
Signal Cable Length | 200 m | 100 m | - |
Main Function | - Easy Setup Wizard - Trend Graph Display Function - Data Logging Function (with microSD card) - Parameter Backup / Restore / Duplication Function (with microSD card) - Zero Adjustment - Display Test Function - Input/Output Test Function |
||
Diagnostic Function | [Application Diagnostics] - Electrode Adhesion Detection - Sensor Empty Check - Wiring Connection Diagnosis - Flow Noise Diagnosis - Low Conductivity Diagnosis - Electrode Insulation - Deterioration Diagnosis |
[Application Diagnostics] - Electrode Adhesion Detection - Sensor Empty Check - Wiring Connection Diagnosis |
|
[Verification Function] - Built-in Verification - Standard Verification (with FSA130 ADMAG TI Verification Tool) - Enhanced Verification (with FSA130 ADMAG TI Verification Tool) |
|||
Current Signal | Input: 1 ch (Active) Output: 2 ch (Active) |
Output: 1 ch (Active) | |
Pulse/Status Signal | Output: 2 ch (Active [With / Without Internal Resister] / Passive) | Output: 2 ch (Active [Without Internal Resister] / Passive) | |
Status Signal | Input: 2 ch (Dry Contact) Output: 2 ch (Passive) |
Input: 1 ch (Dry Contact) | |
Alarm Signal | Output: 1 ch (Passive) | - | |
Multiple Languages | English, French, German, Italian, Spanish, Portuguese, Russian and Japanese. | ||
Safety Integrity Level | - | SIL2 | |
Others | [AXG1A/AXW4A Transmitter, AXW Integral Type] - LCD with improved environmental resistance [AXG1A Transmitter] - Equipped with temperature input terminal for Density correction and Calolie calculation |
Available to combine with high grade transmitter AXG1A
High grade transmitter AXG1A is lined up as a successor to AXFA11.
Same as AXFA11, High grade transmitter AXG1A can be combined with AXW flow sensor.
The position of the input / output terminals and the hole position of the stanchion mounting position are inherited, making it easy to replace AXFA11 with AXG1A.
Main application example
It is an ideal product for general industrial processes and water and sewage applications.
A lining material with excellent wear resistance and corrosion resistance is available to provide highly accurate and stable flow measurement.
Industries | Typical Line and Process | Typical Fluid |
---|---|---|
General Industry | - Water supply line | - Water - Fluid mainly composed of water |
Water supply and Sewage | - Pharmaceutical process- Drainage line | - Clean water - Sewage - Drainage including oil |
Fluorocarbon PTFE
- Anti corrosive material
- For chemical industry
- Temp range: -10 to 130°C
Polyurethane rubber
- Anti-abrasive material
- For general use (water application)
- Temp range: -10 to 40°C
Natural hard rubber (Ebonite)
- Anti corrosive material
- For oily waste water
- Temp range: -5 to 80℃
Natural soft rubber
- Anti abrasive material
- For mining industry and so on
- Temp range: -10 to 70°C
Total Insight - Simplified Selection -
Product Finder
Have you ever struggled to select the most suitable product / specification for the process being measured?
The product selection support tool "Product Finder" that operates on our website supports you.
It is available to select more easily the most suitable products and specifications for the purpose and measurement conditions.
Total Insight - Smart Assist -
Multiple Language
ADMAG AXW supports not only English but also nine languages in total:
French, German, Italian, Spanish, Portuguese, Russian, Chinese, and Japanese.
This helps to prevent stress, misunderstandings, and parameter setting errors that occur when using languages that you are not familiar with.
Wizard Function
Have you ever been struggling to set up the necessary parameters at startup time?
With ADMAG AXG, it is available to set interactively the minimum required parameters for operation start in an interactive manner.
Cable Connection Checking Function
When installing multiple transmitters and detectors at one time, have you ever made a mistake in connecting cables?
ADMAG AXW diagnoses whether the transmitter and detector are connected in the correct combination.
This helps reduce start-up wasted time caused by incorrect cable connections.
Total Insight - Process Guard -
Detection of Electrode Adhesion (Insulator)
If you remove the detector and check the inside, there are no deposits, and as a result there is no experience in wasting the removal work?
With ADMAG AXW, it is available to monitor the adhesion of the electrode while continuing the flow measurement without removing the detector.
This contributes to the development of a maintenance plan.
Process Data Trend Display
Have you ever wanted to simply grasp the process values in a trend graph without using external equipment?
ADMAG AXW can display process values as trend graphs, as well as numerical information, and can “visualize” process value changes from the past to the present. This function displays one process value per screen, and it can switch up to four process values by switching the screen.
There are 11 types of process values that can be displayed, and 6 types of screen update cycles.
The vertical axis is scaled automatically and always displays a graph that is easy to see.
Items | Parameters |
---|---|
Displayable Data | Flow rate (%), PV, Velocity, Volume flow, Mass flow, Calorie, Analog Out 1/2, Totalizer 1/2/3 |
Display Update Period | 0.2s, 0.4s, 1s, 2s, 4s, 8s |
Data Logging Function
Have you ever wanted to simply record process information without using an external device?
ADMAG AXW can be equipped with a microSD card (optional) and can store process information. This makes it possible to record process information simply if there is a device itself. Also, data is stored in text format. Therefore, analysis using spreadsheet software is also possible by importing data into a PC via a microSD card.
This function can record up to four process information simultaneously. Ten types of recordable process information are available. It is available to set the sampling cycle from 7 types and the continuous recording time from 8 types.
Items | Parameters |
---|---|
Recordable Data | PV, Velocity, Volume flow, Mass flow, Calorie, Flow Noise Value, Resistance Value of the electrode Adhesion Detection, Voltage of Electrodes (A, B), Peak Value of the Flow Rate Signal |
Interval Time | 1s, 10s, 30s, 1m, 5m, 30m, 1h |
Recordable Time | 10m, 30m, 1h, 3h, 12h, 24h, 72, 240h |
Total Insight - Expert Solution -
Verification (Device Health Diagnosis) Function
How long does it take each device to carry out an equipment inspection?
It varies according to application and process, inspection item and worker skill.
ADMAG AXW offers the following three methods to easily diagnose the soundness of equipment.
It is available to choose the best diagnosis method according to the situation and the diagnosis you want to check.
Anyone can check the same item automatically.
Items | Description |
---|---|
Built-in Verification | Simple diagnostic function that can be executed by a single device. |
Standard/Enhanced Verification | More fundamental diagnostic function that utilizes FieldMate. In addition, Enhanced Verification allows for more accurate diagnostics. |
Built-in Verification Function (Our proprietary patented technology)
Built-in verification diagnoses the integrity of the transmitter and detector.
As the soundness of the converter, it diagnoses three items: “Calculation circuit”, “Device status (error history)” and “Connection status”.
We diagnose two of "magnetic circuit" and "excitation circuit" as soundness of the detector.
Then, based on the results of these five soundness diagnoses, the soundness of the entire device is diagnosed.
Standard Verification
In addition to the diagnostic content of the built-in verification function, the standard verification function can inspect the appearance of the chassis and display board, and diagnose the dot missing of the LCD.
In addition, since the diagnosis results can be output as A4 size PDF, they can be used as supplementary data for reporting and management of inspection history. To use the standard verification function, separately purchase the "FSA130 ADMAG TI Verification Tool".
Enhanced Verification
The extended verification function can diagnose the soundness of current input / output, pulse output, transducer accuracy, and electrode insulation resistance by using external devices in addition to the standard verification diagnostic contents.
In addition, manual input of the diagnosis results not only increase the number of diagnosis items but also improve the diagnosis accuracy of the soundness. This also can output the diagnosis result as A4 size PDF.
To use the extended verification function, separately purchase the "FSA130 ADMAG TI Verification Tool".
Available microSD Card
Have you ever taken the time to backup device parameters, copy parameters to replacement devices, etc.?
Also, have you ever wanted to simply record process information without using an external device?
With ADMAG AXW, you can install microSD card to the converter by selecting option.
Using the microSD card enables easy recording of process information in addition to backup / restore / duplication of parameters, which is useful for improving maintenance work efficiency and analyzing process status.
Parameter Backup / Restore / Duplication Function
ADMAG AXW can be equipped with a microSD card (optional) and can backup / restore / duplicate parameter information using the microSD card or a memory with a built-in LCD.
Function | Description |
---|---|
Backup | Save parameter information to microSD card or memory with built-in LCD |
Restore | Download parameter information to the same device (Device A to A) |
Duplication | Download parameter information to other devices with the same model name and the same specification code (Device A to B) |
With these functions, for example, if there is a defect in the parameter settings, you can restore the previous settings.
In addition, since the factory settings are maintained, it is possible to reset to the factory settings.
Furthermore, it is possible to duplicate multiple devices with the same parameters, which contributes to the realization of rapid device replacement.
Data Logging Function
Have you ever wanted to simply record process information without using an external device?
ADMAG AXW can be equipped with a microSD card (optional) and can store process information. This makes it possible to record process information simply if there is a device itself. Also, data is stored in text format. Therefore, analysis using spreadsheet software is also possible by importing data into a PC via a microSD card.
This function can record up to four process information simultaneously. Ten types of recordable process information are available. It is available to set the sampling cycle from 7 types and the continuous recording time from 8 types.
Items | Parameters |
---|---|
Recordable Data | PV, Velocity, Volume flow, Mass flow, Calorie, Flow Noise Value, Resistance Value of the electrode Adhesion Detection, Voltage of Electrodes (A, B), Peak Value of the Flow Rate Signal |
Interval Time | 1s, 10s, 30s, 1m, 5m, 30m, 1h |
Recordable Time | 10m, 30m, 1h, 3h, 12h, 24h, 72h, 240h |
Dual Frequency Excitation Method
By combining the signals obtained by low frequency excitation and high frequency excitation, it is our unique revolutionary excitation method that has succeeded in covering each defect and extracting only the superiority.
It combines the advantages of low frequency excitation zero points stability, high frequency excitation noise resistance and high speed response.
Both noise resistance and zero points stability
The fluid noise that appears when measuring slurry fluid or low conductivity fluid has "1/f characteristics".
In other words, low frequency components tend to be noisy, while high frequency components tend to be less noisy.
Therefore, high frequency excitation is effective to ensure noise resistance.
However, in conventional high frequency excitation, there was a problem that "zero points become unstable".
In "Dual Frequency Excitation Method", sampling is performed in the area not affected by noise on the high frequency side, and stable zero points components are extracted with a large time constant on the low frequency side.
Therefore, the synthesized signal has a very small effect of noise and stable zero points.
"0.1 seconds" fast response
In order to realize the stability of the zero points while reducing the influence of noise, the time constant is generally increased.
But that would hurt responsiveness.
The solution is "Dual Frequency Excitation Method" how to simultaneously meet the effects of noise reduction, zero points stability and response.
In “Dual Frequency Excitation Method”, high-speed response of “0.1 seconds” is possible because the change in flow rate is detected on the high frequency side.
Display and output of Flow Noise Intensity
Conventional models have removed fluid noise signals using our proprietary signal processing technology "Dual Frequency Excitation Method". On the other hand, understanding the fluid noise signal is also useful for identifying the cause of occurrence and preventing it.
With ADMAG AXG, the intensity of fluid noise can be displayed and output separately from flow signal output.
As a result, while realizing stable flow rate measurement, it has become possible to grasp at what intensity fluid noise is generated.
This makes it possible to monitor conditions such as air bubble / slurry contamination, lining wear, and liquid replacement (chemical injection, cleaning) that are the causes of fluid noise.
Electrode Adhesion Detection
Preventing electrode adhesion in advance is one point of stable flow rate measurement.
With ADMAG AXW, the degree of adhesion can be displayed in 4 levels.
In addition, the degree of adhesion in the detector can be grasped while installed in piping, which contributes to the reduction of inspection man-hours.
Sensor Empty Check
The electromagnetic flowmeter can not perform accurate measurement if the inside of the detector is empty (non-full).
In ADMAG AXW, by constantly monitoring the condition in the piping, it contributes to the realization of continuous and stable flow measurement.
FSA130 ADMAG TI Verification Tool
FSA130 ADMAG TI Verification Tool is software that operates on FieldMate that can diagnose the health of the electromagnetic flowmeter.
Using this software, you can not only easily check the soundness of flow measurement but also output a diagnostic result report that can be used as report data.
Furthermore, by connecting to an external device, you can perform a more thorough equipment health diagnosis.
Click here for details of FSA130 ADMAG TI Verification Tool
Click here for details of FieldMate
AM012 Calibrator for Magnetic Flowmeter
AM012 Calibrator for Magnetic Flowmeter is a standard signal generator that can be used for calibration and operation check of our electromagnetic flowmeter.
It is available to calibrate the converter and check its operation without the need for a detector.
The span can be arbitrarily set every 0.01 m/s in the range of 0 to 10.99 m/s.
In addition, the generated output signal for the set span can be switched to the value of 0, 25, 50, 75, 100% by the output setting dial.
A150 Handy Calibrator
CA150 Handy Calibrator is a measuring instrument that can simultaneously generate and measure signals at the time of configuration and equipment check at the maintenance site.
By using this product, you can check the soundness of the DC voltage / current output and pulse output of the electromagnetic flowmeter.
"CA150 Handy Calibrator" is a product of Yokogawa Test & Measurement Corporation.
MY600 Digital Insulation Tester
MY600 Digital Insulation Tester is a measuring device to check the insulation condition of the electric circuit.
By using this product, it is available to check the soundness of the excitation coil mounted on the detector side of the electromagnetic flowmeter and the insulation resistance of the electrode.
"MY600 Digital Insulation Tester" is a product of Yokogawa Test & Measurement Corporation.
Recursos
Hydro power
Descargas
Catálogos
Manuales
- Magnetic Flowmeter Read Me First (1.2 MB)
- ADMAG TI Series AXG###, AXW###, AXG4A, AXW4A, AXG1A Magnetic Flowmeter Read Me First (Optional Code EC) (847 KB)
- ADMAG TI Series AXG/AXW Magnetic Flowmeter Safety Manual (394 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Installation Manual *See Manual Change No. 23-120624-E (8.5 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1800 mm (20 to 72 in.)] Installation Manual (7.4 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 1800 mm (1 to 72 in.)] Maintenance Manual (2.8 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter PROFIBUS PA Communication Type (3.9 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter BRAIN Communication Type (5.3 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter Modbus Communication Type (2.7 MB)
- ADMAG TI Series AXG and AXW Magnetic Flowmeter ATEX Explosion Protection Type (1.4 MB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter BRAIN Communication Type (5.3 MB)
- ADMAG TI Series AXG and AXW Magnetic Flowmeter IECEx Explosion Protection Type (1.3 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter HART Communication Type (4.8 MB)
- ADMAG TI Verification Tool (44.4 MB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter HART Communication Type (4.8 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter EtherNet/IP Communication Type (4.2 MB)
- ADMAG TI Series AXG, AXW Magnetic Flowmeter FOUNDATION Fieldbus Communication Type *See Manual Change No. 23-120758-E (4.1 MB)
Especificaciones Generales
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] (3.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1800 mm (20 to 72 in.)] (2.3 MB)
- ADMAG TI Series AXW Electromagnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Marine Approval Type (751 KB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter (1.2 MB)
- ADMAG Total Insight Series FOUNDATION Fieldbus Communication Type AXG/AXW Magnetic Flowmeter (918 KB)
- FSA130 Magnetic Flowmeter / Vortex Flowmeter Verification Tool (1.4 MB)
Planos
- ADMAG TI Series AXW Magnetic Flowmeter AXW4A Remote Transmitter (714 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Wafer (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange ASME Class 150 (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange ASME Class 300 (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange EN PN16, EN PN40 (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange EN PN10 (800 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange JIS F12 (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange JIS 10K (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Flange JIS 20K (1.3 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 25 to 400 mm (1 to 16 in.)] Grounding Ring (Optional Code GRN, GRJ) (Handle Bracke (554 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange ASME (Process Connection Code CA1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange AWWA (Process Connection Code CB1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange EN PN10 (Process Connection Code CE1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange EN PN16 (Process Connection Code CE2) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange JIS 10K (Process Connection Code CJ1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange AS2129 Table D (Process Connection Code CS1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange AS2129 Table E (Process Connection Code CS2) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange AS4087 PN16 (Process Connection Code CT1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1000 mm (20 to 40 in.)] Flange JIS F12 (Process Connection Code CG1) (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 1100 to 1800 mm (44 to 72 in.)] Flange AWWA (Process Connection Code CB1) (827 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 1100 to 1800 mm (44 to 72 in.)] Flange EN PN6 (Process Connection Code CEJ) (827 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 1100 to 1800 mm (44 to 72 in.)] Flange EN PN10 (Process Connection Code CEK) (828 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 1100 to 1800 mm (44 to 72 in.)] Flange EN PN10 (Process Connection Code CE1) (828 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 1100 to 1800 mm (44 to 72 in.)] Flange AS2129, AS4087 (Process Connection Code CS1 (827 KB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 1100 to 1800 mm (44 to 72 in.)] Flange JIS F12 (Process Connection Code CG1) Groun (1.1 MB)
- ADMAG TI Series AXW Magnetic Flowmeter [Size: 500 to 1800 mm (20 to 72 in.)] Grounding Ring (Optional Code GR1) (631 KB)
- ADMAG TI Series AX01C Magnetic Flowmeter Signal Cable (538 KB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter (717 KB)
- ADMAG TI Series AXG1A Magnetic Flowmeter Remote Transmitter (AM11 Replacement Bracket) (Optional Code RK) (703 KB)
2D/3D Configurator
Noticias
-
Nota de Prensa abr 27, 2017 Yokogawa Develops the ADMAG Total Insight Electromagnetic Flowmeters
- Optimizing operations and reducing maintenance costs at all phases of the product lifecycle -
¿En busca de información adicional sobre Yokogawa Iberia, tecnología y soluciones?
Contáctenos