Electrolysis Plant Trace H2O (Moisture) Measurement by the TDLS8000

Download (325.5 KB)

Introduction

If water is present after the dry chlorine tower in brine electrolysis plants, the downstream compressor is corroded or the product quality is deteriorated. The moisture level is measured before and after the compressor to prevent the corrosion of the compressor and the deterioration of quality. Conventional trace moisture analyzers using a phosphorus pentoxide (P2O5) sensor measure process gas with the contacting sensor so there are problems such as the deterioration of the sensor, slow response time, high maintenance, and high running costs. The TDLS8000 Laser Analyzer is the solution to these problems.

 

Process Overview

Chlorine gas generated in the brine electrolysis plant is dehumidified in the wet chlorine tower and sent to the drying tower where the chlorine gas is dried using sulfuric acid solution. The dried chloride gas is sent to the dry chloride tower where the gas is dehumidified, and finally, the dry chloride gas is compressed by the compressor and liquefied, and then shipped as a product.

 

Expected Benefits

  • Reliable measurement with less deterioration by non-contact measurement
  • Ability to measure even corrosive gasses with less deterioration reduces the maintenance and running costs
  • Fast response to and stable measurement of changes in H2O concentration

Electrolysis Plant
Electrolysis Plant

 

Solution Details

Unlike analyzers using a phosphorus pentoxide (P2O5) sensor, the TDLS responds fast to changes in the trace moisture of the sample.

 

Field Data

Responsiveness Comparison between the TDLS and Moisture Analyzer Using P2O5 Sensor

Field Data

 

Configuration Example of TDLS8000 Laser Analyzer Trace Moisture Measurement

A sampling system is used to introduce a process gas into the flow cell to measure it.

Configuration Example of TDLS8000 Laser Analyzer Trace Moisture Measurement

 

Features

  • A proprietary sampling method enables a high-sensitivity measurement (in the minimum range of 0-30 ppm)
  • In-situ calibration is possible without removing the system
  • The sampling system minimizes the effect of moisture in the purge gas

 

TDLS Analyzer

  • TDLS8000
    Available on a special order basis.

 

Notes

  • Power supply: 100 - 240 V AC, 50/60 Hz
  • Purge gas: Instrumentation and N2
    Inside the sampling board and the light emitter and light receiver boxes
    Purge: Instrumentation air 10 L/min
    Laser light transmission region purge: N2 flow rate 5 L/min

 

 

Related Industries

  • Chemicals

    Chemical products are indispensable to modern life and industry. Chemical plants, where these products are manufactured, are required to maintain stable operations 24 hours a day, 365 days a year while achieving high levels of safety, productivity, and sustainability. Leveraging more than 100 years of expertise in measurement and control, together with digital technologies such as AI, Yokogawa helps chemical industry customers achieve sustainable growth. Together with Yokogawa, shape the future of your manufacturing operations.

Related Products & Solutions

  • In-Situ Gas Analyzer TDLS8000

    Yokogawa’s new TDLS™8000 houses all of the industry’s leading features in one robust device. The platform design is for in situ measurements which negate the need for sample extraction and conditioning.

  • Oxygen Analyzers

    Oxygen analyzers provide valuable measurements in combustion control, process quality, safety and environmental applications.


Top