WX102 DAQ32Plus
Notice: This product was discontinued on Mar 30, 2015. See this replacement product:

Data Acquisition Software for DARWIN

  • High speed data acquisition (as fast as 0.5 seconds) on 360 channels (including MATH channels)
  • Supports Ethernet/RS-232/RS-422/RS-485/GP-IB

Data Logging Software

With this software, you can freely allocate up to 32 measurement and computation channels and define a maximum of 30 channel groups. By opening multiple windows, you can monitor data simultaneously on multiple channels.

Data Logging Software

  1. Monitor manager
    The monitor manager is used to start and stop logging, and to keep track of monitor group settings. The individual monitor windows are launched from the monitor manager.
  2. Alarm overview
    The alarm overview displays alarm statuses group by group. The alarms for all groups can be viewed at the same time so that you won't miss any alarms.
  3. Meter display
    Level meters, analog meters, and thermometers can be set as desired on each channel to create an effective monitor screen.
  4. Digital value display
    Current values are displayed without modification in this area. This display is useful for acquiring detailed information when a problem occurs.
  5. Analog trend display
    This display presents measurement and computation value as analog trend. It can also "play back" the most recent 1800 data points.
  6. Color monitor display
    The color monitor display allows measurements to be color-coded using as many as fifty color gradations from red to blue. This feature is useful for gaining a visual sense of temperature trends and making visual comparisons of measurements taken on multiple channels.

Data Viewer Software

DAQ32 Plus allows multiple window display of historical data from DC100 and DR recorders floppy disks or PC hard drives. This data can be displayed in a variety of forms, such as analog trend, digital values, and alarm logs.

Data viewer software

  1. Analog trend display
    The analog trend display feature allows you to display up to 30 windows of channel data each containing as many as 32 channels. You can switch between the windows one at a time, and the color monitor display can also be used simultaneously.
  2. Point to point statistics
    Displays statistical computations for the data between the cursors.
  3. Print previewData conversion screen (Excel)
    Historical data can be converted to Lotus 1-2-3(version 1A is supported), Excel(version 4 is supported), and ASCII formats.
  4. Digital value display
    The digital value display feature allows you to display up to 30 windows of data each containing as many as 32 channels. You can switch between the windows one at a time.
  5. Print preview (analog trend)
    Displayed information can also be output to a color printer.

DARWIN Configuration Software

DARWIN Configuration Software

This software configurations the DA100, DC100, and DR Series. Configurations can be uploaded/downloaded between DARWIN and your PC, including measurement ranges, measurement cycles, measurement start times, alarms, events/actions, and formulas. Settings can be stored on your PC's hard drive or a floppy disk for reuse. The setting screens use easy to view table formats.

Environment Setting Software

Environment Setting Software

  • Set the communication mode to be used in communication with DARWIN
  • Set the directory for saving data
  • Display the DARWIN ROM version information
  • Initialize the settings.

You can also graphically display the system configuration, including modules installed in DARWIN, and reconfigure the system as necessary when you change the modules installed in the DA100, DC100, or DR Series (expandable model). This software can also be used to calibrate DARWIN input modules.

Tag Setting Software

Tag Setting Software

There are two types of tags: TAG NOs, which can be entered as up to 8 standard-width characters; and TAG COMMENTs, which can be entered as up to 16 standard-width characters. Tags can be displayed instead of channel numbers in the data logging software or the viewer software. With the DC100 and DR series, tags set using keys on the main unit can be loaded in the tag setting software, and tags set in the software can be sent to the main unit.

Remote Monitoring Client for DAQ32Plus

DAQ32Plus Client

DAQ32Plus Client is client software designed to remotely access the monitor server of DAQ32Plus installed in the server PC on an Ethernet. Simultaneous remote access is possible from a maximum of 8 client PCs on the Ethernet to the DAQ32Plus monitor server of the server PC. In addition, simultaneous access can be made from a separate remote monitoring software component to a maximum of 8 monitor servers for remote monitoring.

Note that the remote monitors for DAQLOGGER Client, DAQ32Plus and DAQ32Plus Client, and data monitor for DAQEXPLORER cannot be used at the same time on the same PC.

Combination with High-value Added Software

  • Advanced recording (multiple logging)
    The multi-logging of 32 channels x 50 groups is avaialble by groups in combination with Addmulti.
  • Advanced recording (triggered logging)
    The event logging with advanced trigger conditions is available in combination with AddTrigger.
  • Advanced monitoring (user-created screens)
    User-created screens offer convenient monitoring in real time in combination with AddObserver and AddObserver Runtime.

Resources

The exclamation point is displayed when data cannot be written to the hard disk. Check whether the save destination folder exists, and whether there is sufficient free space on the disk.
If you have not changed any settings, check the following. Check the amount of free space on the hard disk, and perform error checking Check the DA100 power, and whether the green STATUS lamp is lit Communication cable connection and replacement...
Upload settings as follows: Darwin setting icon > Communication > Receive. Next, select Communication > Execute > Balance. Select Balance for the execute type, then select the range of channels and execute the balancing. (Setting the exec...
Yes, with the auto processor.
Since the OS security level has increased, you can no longer set the Ethernet module's IP address on Windows 7. Data acquisition will be unaffected, but for the IP address setting use a Windows XP PC with DAQ32 installed.
Use the latest version of SMARTDAC+ Standard Universal Viewer.
It can monitor up to 20 channels. If you need more channels, please consider DAQ32Plus (supports up to 300 channels).
It is a number starting with 101, and is included in your DAQ32Plus CD case. If you lose the license number, order model no. WX102.
Communication cannot open if the IP address is the same.
No. DAQ32Plus only supports 1 unit. We recommend using DAQLOGGER.
Ethernet, RS-232C, RS-422A/485, and GPIB.
Launch the DAQ32Plus monitor, then start the client.
Up to 30 groups of up to 32 channels each can be created. You can set the display span in the detailed display settings.
Yes, by using the DAQ32Plus client package. The latest version supports monitoring of 1 DAQ32Plus monitor server by up to 16 clients.
Check whether "Alarm data" is checked in the DAQ32Plus Logger acquisition conditions. If not, the alarm on the DAQ32Plus screen remains green and doesn't turn red even if an alarm is reported on the DARWIN hardware.
The time in the trends is the time on the DA100. When connected for a long time, the times on the PC and DA100 can start to diverge. Closing and then reopening the connection will synchronize the times because the PC's time is automatically set o...
Double-click the DAQ32Plus environment settings icon, click the Environment tab, and make sure ETHERNET is selected and that the DA100's IP address is set. If the IP address is not set, set it and then restart DAQ32Plus.
Because DAQ32 Plus has greater functionality than DAQ32, it requires that much more CPU speed and memory. If there was no problem on DAQ32 but the performance bar goes to OVER on DAQ32 Plus, probably the baud rate set on DAQ32 is too slow for DAQ32 P...
You can, starting with style 8 of the DA. Setting command: VS. Control execute command: VD. The DR and DC do not support this. With DAQ32 and DAQ32Plus you can set up output relays, but you can't actually operate them with commands. You can also ...
Generally they are not initialized if the modules are not different from the previous system. However, initialization happens if slots are in the following conditions. Slot replaced with a module of a different model name or style number Slot who...
On the RS232C communication module, set communication parameters by using the dip switches on the front of the module. Make sure the communication module’s dip switches match what is displayed on the DAQ32's “Environment, diagnosis, a...
For 0.5 second models, temperature is measured for RJC every 2.5 seconds (with a 0.5 second scan, since the time for processing temperature measurement, burnout, and other factors is too short, measurement occurs every 5 cycles). For 2.0 second mode...
For voltage measurement, if 5% of range + range span is exceeded, an overrange occurs (±32767 is output). For temperature range, the +10°C measuring range is the upper limit. Ex) For the ±50 V range (span of -50 to +50), the upper l...
Does DARWIN support Windows XP?
(ns-faq-darwin-8017-spec)
R10.03 and later support Windows XP.
DAQ32 (DP120) or DAQWORX DAQ32 Plus (WX102) installed on Windows 7 or Windows Vista cannot change the IP address of DARWIN series Ethernet modules (suffix code /C7) or DARWIN series standalone models with the Ethernet communications option (model cod...
Yes. Set the IP address, subnet mask, and default gateway on the main unit.
The voltage generated when a burnout current of 4.2 mA flows to the measuring terminal circuit is measured in the 60 mV range, and a determination is made. If 42 mV (10 kΩ) or more, the result is 0 (open). If less than that, 1 (closed).

Downloads

Looking for more information on our people, technology and solutions?

Contact Us

Top