pH- und Redoxsensoren

pH-Elektroden und -Sensoren sind die detektierenden Elemente bei der Messung des pH-Werts. Die verschiedenen Installationsoptionen schließen u. a. Wechsel-, Durchfluss- und Eintaucharmaturen sowie den direkten Einbau ein. Die richtige Auswahl von pH-Elektroden und Sensoren ist für optimale Messergebnisse von entscheidender Bedeutung.

  • pH/ORP Sensors PH8EFP, PH8ERP, OR8EFG, OR8ERG

    Yokogawa's pH and ORP analyzers are highly reliable. They feature advanced functions and are useful for a wide variety of applications including water quality management in a broad range of production processes and in medium-sized wastewater treatment plants, or as general pH and ORP control systems.

    Mehr anzeigen
  • Differenz-pH-/ORP-Sensoren

    Die Kationen-Differenz-pH- und ORP-Sensoren wurden für schwierige Anwendungen entwickelt, bei denen herkömmliche Sensoren nicht effektiv sind. Dazu gehören Messungen in Solelösungen bis hin zu so diversen Anwendungen wie Elektrolyseverfahren und der Käseproduktion.

    Mehr anzeigen
  • pH- und ORP-Sensoren für Reinwasser

    Mit einem traditionellen pH-Analysator genaue und verlässliche Messwerte zu erzielen ist eine Herausforderung, aber mit der richtigen Ausrüstung lassen sich stabile und präzise Reinwasser-pH-Messungen erreichen. Der spezielle Bellomatic-pH-Sensor von Yokogawa ist eine bewährte optimale Lösung für Reinstwasseranwendungen. Für Anwender, die sich die Wartung von Nachfüllsensoren ersparen möchten, ist der FU24 mit dem erfolgreichen, patentierten und in das All-in-One-Gehäuse integrierten Faltenbalgsystem die ideale Lösung.

    Mehr anzeigen
  • Handmessgerät PH71/PH72

    Das Messgerät PH71/PH72 für pH und/oder ORP (Redox) ist kompakt, benutzerfreundlich, wasserdicht und ideal für den Feldeinsatz. Mit „One-Touch-Kalibrierung“ und Temperaturkompensation. Intelligente pH-Messgeräte in Laborqualität – preiswert, im tragbaren Taschenformat

    Mehr anzeigen
  • Durchfluss/NPT-Armaturen FF20/FS20

    Yokogawa hat viel Aufwand und Zeit in die Entwicklung einer breiten Palette von Armaturen investiert. Ein besonderer Schwerpunkt lag dabei auf der Senkung von Installations- und Wartungskosten und somit günstigeren Betriebskosten.

    Mehr anzeigen
  • Eintaucharmatur FD20

    Die Eintaucharmaturen sind für pH- oder ORP (Redox)-Messungen in Tanks, offenen Behältern oder Drainagen vorgesehen. Sie verfügen über eine Halteschlaufe zum Herausziehen für eine einfache Wartung.

    Mehr anzeigen
  • Wechselarmatur PR10

    Online-Messungen stellen oft eine besondere Herausforderung dar, insbesondere wenn Routinewartung erforderlich ist. Die PR10 ist ideal geeignet für Anwendungen, bei denen die Sensoren entfernt werden müssen, ohne den Prozess zu unterbrechen oder abzustellen. Ohne irgendwelche Spezialwerkzeuge kann die PR10 bei Drücken von bis zu 5 bar (72 psi) sicher aus dem Prozess gezogen werden. Mit der PR10 kann jeder beliebige Gelöstsauerstoffsensor mit PG13.5-Anschluss in eine Wechselarmatur eingesetzt werden.

    Mehr anzeigen
  • Verlängerungs-Anschlussbox BA10/WTB10

    Bei größeren Entfernungen zwischen der Messstelle und dem Analysator, insbesondere wenn die Entfernung die Länge der Standard-Elektrodenkabel überschreitet, bietet dieses Anschlusszubehör eine zweckmäßige Möglichkeit zum Anschluss der Sensorkabel an das Messinstrument.

    Mehr anzeigen
  • EXAtrac RF20 Pneumatische Wechselarmatur

    Die pneumatische Wechselarmatur EXAtrac RF 20 (Extrac 810 und 820) ist für die Installation von 12mm-Sensoren an Tanks oder Rohrleitungen vorgesehen, wo der Sensor ohne Unterbrechung oder Abschaltung des Prozessstroms entfernt werden muss und für schwierige Anwendungen, bei denen eine häufige Reinigung für eine gute pH-Messung von entscheidender Bedeutung ist.

    Mehr anzeigen
  • EXA Compact

    EXA Compact ist erhältlich mit Durchfluss-, Einbau- und Eintaucharmaturen. Durch die große Palette lieferbarer Prozessanschlüsse gestaltet sich die Installation in einem Tank, einem offenen Behälter oder einer Rohr- bzw. Bypass-Leitung sehr einfach. Dank der sorgfältigen Auswahl chemisch beständiger Materialien eignen sich die Sensoren für die meisten Prozesse.

    Mehr anzeigen
  • pH/ORP-Pufferkalibrierlösungen

    Pufferlösungen sind erforderlich als unverzichtbares Werkzeug zur Aufrechterhaltung genauer pH -Messungen. Pufferlösungen dienen als Referenzpunkte für die Kalibrierung und Justierung von pH -Messungen zur Kompensation von Alterung und Verschleiß.

    Mehr anzeigen
  • WU10 Kabel

    Universelles Sensorkabel zur zuverlässigen Übertragung analoger Signale, das speziell für die Installation in Schwerindustrieumgebungen konzipiert wurde.

    Mehr anzeigen
  • Produktfinder

    Der "Product Finder" ist ein Web-Tool, das es Ihnen ermöglicht Produkte hinsichtlich ihrer Anwendung, Messbedingungen und erforderlichen Spezifikationen zu filtern.

    Mehr anzeigen

Publikationen

Übersicht:
  • More than 1,000 field devices designed to the PROFIBUS specifications installed in the state-of-the-art water reclamation plant.
  • The high reliability and accuracy of our field devices contributes to the minimization of maintenance costs over the entire plant lifecycle.
Applikations-beschreibungen
Übersicht:

For control of batch neutralization, a pH measurement coupled with a timer-controlled chemical feed scheme provides very satisfactory results.

This system can be adapted for either acid waste or alkaline waste neutralization.

Applikations-beschreibungen
Übersicht:

There are a number of suppliers of oil and fat products used for edible purposes. These products include, but are not limited to olive oil, peanut oil, soybean oil, sunflower oil, lard, shortening, butter, and margarine. The raw materials for these products include animal by-products, fleshy fruits (palm and olive), and oilseeds. 

Industry:Food and Beverage

Applikations-beschreibungen
Übersicht:

One of the primary applications for high purity water is for boiler feed water. The measurement of pure water pH can be one of the quickest indicators of process contamination in the production or distribution of pure water. Effective chemical treatment of the feed water is vital in maintaining the useful operating life and minimizing maintenance costs of the boiler.

Industry:Power, Pharmaceutical, Common

Industrien:
Industrien:
Applikations-beschreibungen
Übersicht:

The proliferation of microorganisms and the resultant formation of slime is a problem which commonly occurs in aqueous systems. Problematic slime producing microbes may include bacteria, fungi and/or algae. Slime deposits typically occur in many industrial aqueous systems including cooling water systems, pulp and paper mill systems, petroleum operations, clay and pigment slurries, recreational water systems, air washer systems, decorative fountains, food, beverage, and industrial process pasteurizers, sweetwater systems, gas scrubber systems, latex systems, industrial lubricants, cutting fluids, etc.

Industry:Refining, Food and beverage, Power, Oil and Gas, Pulp and Paper, Chemical

Industrien:
Applikations-beschreibungen
Übersicht:

Process liquid analyzers such as pH meters, conductivity meters, ORP meters, and density meters play an important role at electrolysis plants in the control of concentrations of various process solutions. This requires both precision and stability under harsh conditions that include highly corrosive substances, high temperatures, and many impurities.

Übersicht:

Most zinc are produced at hydrometallurgically, where a high-grade zinc product can be obtained and valuable metals mixed in the raw material can be recovered. In the hydrometallurgy, the raw material of zinc concentrate is roasted and then dissolved in sulfuric acid to remove impurities. The process called leaching and pH control of the leachate is important.

Industry:Chemical, Power

Industrien:
Übersicht:

The control of the world's water resource is arguably one of the most important issues. Water demand from industry and domestic users is set to rise throughout the industrialized world. Yokogawa has been applying minimized maintenance measurement systems.

Übersicht:

Cyanide-bearing wastewater from mining and electroplating facilities and certain types of chemical plants is toxic and must be treated by oxidation with chlorine or chloride to bring the cyanide concentration within regulatory limits.

Industry:Electrical and Electronics

Übersicht:

In flue gas desulfurization systems that use magnesium hydroxide (Mg(OH)2) slurry, the consumption of the desulfurization agent (Mg(OH)2) is controlled by using online pH analyzers. A great concern in the pH measurement is heavy staining of the pH electrodes by the Mg(OH)2 slurry. To ensure accurate measurement, frequent cleaning of the electrodes with an acid is required, adding to both maintenance workload and cost.

Industry:Chemical, Power

Übersicht:

Caustic soda and hydrochloric acid, produced in electrolyzer plants, are fundamental materials used in varieties of industries; chemicals, pharmaceuticals, petrol-chemicals, pulp and papers, etc. Profit is the result of the effective production with minimized running / maintenance cost. Proper control of the process brings you stabilized quality of products with the vast operational profit.

Industrien:
Übersicht:

The treatment of wastewater from pulp and paper plants is a serious environmental concern. Yokogawa's submersion holder with an ultrasonic+air-jet cleaner (customized product) can reduce the manual cleaning frequency to just once every one or two months.

Industry:Pulp & Paper

Industrien:
Applikations-beschreibungen
Übersicht:

Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. Problems at the wet end (stock preparation) can rarely be corrected downstream. That is why monitoring and controlling pH in pulp stock is critical to the paper making process. Essentially, at every stage in the manufacture of paper, correct pH values play a vital role.

Applikations-beschreibungen
Übersicht:

Reverse osmosis (RO) is a separation process that uses pressure to force a solution through a membrane that retains the solute on one side and allows the pure solvent to pass to the other side. More formally, it is the process of forcing a solvent from a region of high solute concentration through a membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure.

Übersicht:

Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.

Industrien:
Übersicht:

Wastewater from electroplating facilities and certain types of chemical plants contains toxic forms of hexavalent chromium such as chromate and dichromate. The hexavalent chromium in this wastewater must be reduced before the water can be discharged. This requires a two-step process: hexavalent chromium (CR6) is reduced to trivalent chromium (CR3); and CR3 is precipitated as chromium hydroxide.

Industry:Electrical and Electronics

Applikations-beschreibungen
Übersicht:

Sour Water is the wastewater that is produced from atmospheric and vacuum crude columns at refineries. Hydrogen sulfide and ammonia are typical components in sour water that need to be removed before the water can be reused elsewhere in the plant. Removal of these components is done by sending the sour water from the process to a stripping tower where heat, in the form of steam, is applied.

Industrien:
Applikations-beschreibungen
Übersicht:

Power plant boiler houses designed to burn coal or high sulfur oil are required by Federal and State pollution regulations to "scrub" (remove) sulfur dioxide from flue gasses to meet emission limits. SO2 in flue gasses is known to be harmful to the environment, as it is one contributor to the formation of acid rain. pH control is critical for the proper functioning of the scrubber system.

Industrien:
Applikations-beschreibungen
Übersicht:

Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid. 

Industrien:
Applikations-beschreibungen
Industrien:
Übersicht:

The lifetime of a pH sensor has a significant impact on the overall annual costs of a pH measuring loop. Optimizing four key factors will decrease these costs and optimize process control and overall plant efficiency.

White Paper
Übersicht:

ORP (Oxidation-Reduction Potential) is the measurement, in millivolts, of a solution's capacity for electron transfer (oxidation or reduction). ORP measurement may also be called REDOX for REDuction OXidation. The name reflects that fact that within a chemical reaction reduction and oxidation are complementary; one cannot occur without the other.

Übersicht:

To facilitate the accurate measurement of pH, and its presentation as a scale, a range of "standard liquids" or "buffer solutions" are used. These liquids, whose constituents are accurately defined, have known stable values. Although in the preceding text the relationship to hydrogen ions has been made, research has shown, that the activity of hydroxonium ions (H30+) is more relevant.

Industrien:

Downloads

Videos

Möchten Sie weitere Informationen über unsere Mitarbeiter, Technologien und Lösungen?

Kontakt

Top