pH电极和传感器是进行pH值测量的传感部分,有伸缩式、流通式、浸入式和直插式等多种安装选项。选择合适的pH电极/传感器对优化测量结果至关重要。
-
FU20/FU24/PH20一体化pH/ORP (REDOX)传感器
PH20/FU20/FU24一体化pH/ORP传感器体现了横河电机如何将“简单即好”这句格言应用于传感器技术。
-
PH8EFP、PH8ERP、OR8EFG、OR8ERG pH/ORP传感器
横河电机的pH/ORP分析仪可靠性很高,具有多种先进功能且应用广泛,包括在一系列生产过程和中型废水处理厂中进行水质管理,或者用作通用的pH/ORP控制系统。
-
12 mm SC25V pH传感器
SC25V是一款12 mm的pH传感器,包含一个一体型温度元件和一个液体接地电极。
-
差分pH/ORP传感器
阳离子差分pH/ORP传感器用于传统传感器失效的复杂应用,包括盐水溶液以及电解过程和奶酪生产等多种应用的测量。
-
工业pH/ORP电极
pH值测量回路的关键是电极系统。横河电机研发了多种电极,确保电极系统在极其恶劣的条件下也可以运行。
-
纯水pH/ORP传感器
很难使用传统pH分析仪获取准确可靠的读数,但是使用合适的设备即可实现稳定准确的纯水pH值测量。横河电机的专用bellomatic pH传感器是高纯水应用的理想解决方案。对于不想维护填充型传感器的用户,FU24是理想的解决方案。它将已成功获得专利的波纹管系统融入到了一体化本体中。
-
PH8EHP高纯水pH传感器
通过PH8EHP pH传感器和PH8HH支架能够可靠测量锅炉和半导体工艺应用中所用高纯水的pH值。
-
pH/ORP传感器PH4/OR4传感器系列
PH4/OR4传感器系列支持在恶劣条件下进行pH/ORP测量,例如工艺流体被严重污染或含有硫化物。PH4/OR4传感器系列可满足简单的设备要求。
-
Portable pH Meter PH91, Portable pH/ORP Meter PH92
Tough, easy-to-use handheld pH/ORP meter that can be carried anywhere.
It can measure pH and ORP stably and accurately.
As your daily measurement partner. -
PH71/PH72便携式pH/ORP计
PH71/PH72 pH/ORP仪表结构紧凑,易于使用,采用防滴设计-非常适合现场使用。具有“一键校准”和温度补偿功能。实验室级智能pH计–无论是价格还是尺寸都非常适合您的口袋。
-
pH/ORP、DO和MLSS分析仪的传感器支架
横河电机提供多种类型的支架,可以添加清洁剂,根据应用条件选择合适的支架和清洁器,客户可以构建可靠且易于维护的测量系统。
-
pH/ORP Buffer Calibration Solutions
Buffer solutions are needed as an indispensable tool for maintaining an accurate pH measurement. Buffer solutions are used as references points for calibration and adjustment of pH measurements to compensate for aging and deterioration.
-
PH21水/废水宽体传感器
PH21是横河电机产品系列中的宽体传感器,适用于水和废水市场。
-
产品查询
“产品查询”是一种网络工具,可以根据应用、测量条件和所需规格更容易地查找产品。
参考
For control of batch neutralization, a pH measurement coupled with a timer-controlled chemical feed scheme provides very satisfactory results.
This system can be adapted for either acid waste or alkaline waste neutralization.
Wet scrubbers are used in utilities, paper mills, and chemical plants to remove sulfur dioxide (SO2) and other pollutants from gas streams. Undesirable pollutants are removed by contacting the gases with an aqueous solution or slurry containing a sorbent. The most common sorbents are lime, Ca(OH)2, and limestone, CaCO3.
There are a number of suppliers of oil and fat products used for edible purposes. These products include, but are not limited to olive oil, peanut oil, soybean oil, sunflower oil, lard, shortening, butter, and margarine. The raw materials for these products include animal by-products, fleshy fruits (palm and olive), and oilseeds.
Industry:Food and Beverage
The proliferation of microorganisms and the resultant formation of slime is a problem which commonly occurs in aqueous systems. Problematic slime producing microbes may include bacteria, fungi and/or algae. Slime deposits typically occur in many industrial aqueous systems including cooling water systems, pulp and paper mill systems, petroleum operations, clay and pigment slurries, recreational water systems, air washer systems, decorative fountains, food, beverage, and industrial process pasteurizers, sweetwater systems, gas scrubber systems, latex systems, industrial lubricants, cutting fluids, etc.
Industry:Refining, Food and beverage, Power, Oil and Gas, Pulp and Paper, Chemical
One of the primary applications for high purity water is for boiler feed water. The measurement of pure water pH can be one of the quickest indicators of process contamination in the production or distribution of pure water. Effective chemical treatment of the feed water is vital in maintaining the useful operating life and minimizing maintenance costs of the boiler.
Industry:Power, Pharmaceutical, Common
Process liquid analyzers such as pH meters, conductivity meters, ORP meters, and density meters play an important role at electrolysis plants in the control of concentrations of various process solutions. This requires both precision and stability under harsh conditions that include highly corrosive substances, high temperatures, and many impurities.
Caustic soda and hydrochloric acid, produced in electrolyzer plants, are fundamental materials used in varieties of industries; chemicals, pharmaceuticals, petrol-chemicals, pulp and papers, etc. Profit is the result of the effective production with minimized running / maintenance cost. Proper control of the process brings you stabilized quality of products with the vast operational profit.
In flue gas desulfurization systems that use magnesium hydroxide (Mg(OH)2) slurry, the consumption of the desulfurization agent (Mg(OH)2) is controlled by using online pH analyzers. A great concern in the pH measurement is heavy staining of the pH electrodes by the Mg(OH)2 slurry. To ensure accurate measurement, frequent cleaning of the electrodes with an acid is required, adding to both maintenance workload and cost.
Industry:Chemical, Power
The treatment of wastewater from pulp and paper plants is a serious environmental concern. Yokogawa's submersion holder with an ultrasonic+air-jet cleaner (customized product) can reduce the manual cleaning frequency to just once every one or two months.
Industry:Pulp & Paper
Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. Problems at the wet end (stock preparation) can rarely be corrected downstream. That is why monitoring and controlling pH in pulp stock is critical to the paper making process. Essentially, at every stage in the manufacture of paper, correct pH values play a vital role.
Reverse osmosis (RO) is a separation process that uses pressure to force a solution through a membrane that retains the solute on one side and allows the pure solvent to pass to the other side. More formally, it is the process of forcing a solvent from a region of high solute concentration through a membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure.
Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.
Wastewater from electroplating facilities and certain types of chemical plants contains toxic forms of hexavalent chromium such as chromate and dichromate. The hexavalent chromium in this wastewater must be reduced before the water can be discharged. This requires a two-step process: hexavalent chromium (CR6) is reduced to trivalent chromium (CR3); and CR3 is precipitated as chromium hydroxide.
Industry:Electrical and Electronics
Sour Water is the wastewater that is produced from atmospheric and vacuum crude columns at refineries. Hydrogen sulfide and ammonia are typical components in sour water that need to be removed before the water can be reused elsewhere in the plant. Removal of these components is done by sending the sour water from the process to a stripping tower where heat, in the form of steam, is applied.
Power plant boiler houses designed to burn coal or high sulfur oil are required by Federal and State pollution regulations to "scrub" (remove) sulfur dioxide from flue gasses to meet emission limits. SO2 in flue gasses is known to be harmful to the environment, as it is one contributor to the formation of acid rain. pH control is critical for the proper functioning of the scrubber system.
Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid.
ORP (Oxidation-Reduction Potential) is the measurement, in millivolts, of a solution's capacity for electron transfer (oxidation or reduction). ORP measurement may also be called REDOX for REDuction OXidation. The name reflects that fact that within a chemical reaction reduction and oxidation are complementary; one cannot occur without the other.
To facilitate the accurate measurement of pH, and its presentation as a scale, a range of "standard liquids" or "buffer solutions" are used. These liquids, whose constituents are accurately defined, have known stable values. Although in the preceding text the relationship to hydrogen ions has been made, research has shown, that the activity of hydroxonium ions (H30+) is more relevant.
下载
宣传彩页
- Process Analyzers Analytical Instruments and Systems Overview
- Portable pH Meter, pH/ORP Meter, Conductivity Meter (4.8 MB)
- 模块化两线制液体分析仪FLXA21 (10.3 MB)
- 离子膜电解装置应用仪表及解决方案 (2.9 MB)
- Liquid Analyzer Sensors and Fittings (5.9 MB)
- PH71/PH72/SC72 Personal pH, pH/ORP, Conductivity Meters (1.8 MB)
- FLXA402 4-Wire Liquid Analyzer, SA11 SENCOM Smart Adapter (2.9 MB)
- 横河电机水行业成功案例 (12.7 MB)
使用说明书
- Model PR10 Manual Retractable Fitting (5.4 MB)
- Model WU10, WF10 and WE10 - VP cable and extension cable
- Model FF20 Flow fittings Model FS20 Subassembly flow fittings Model FD20 immersion fitting (3.4 MB)
- Model SC25F pH SENCOMR sensor (1.1 MB)
- PUS400G Ultrasonic Oscillator (1.3 MB)
- Model FU24F pH/ORP SENCOMR sensor (1.3 MB)
- Solid Electrolyte (Xerolyt) pH Sensor with Temperature Element (488 KB)
- PH8ECP KCl Filling Type pH Sensor (for electrolysis plant) (566 KB)
- PH8HH pH Holder for High Purity Water (617 KB)
- PH8ERP KCl Refillable type pH Sensor (715 KB)
- PH4/OR4 Sensor Series pH and ORP Sensors (679 KB)
- SPS24 SENCOM Software (1.2 MB)
- PH4B pH Sensor for Small Culture Tank (330 KB)
- PH8AX Accessory Set for pH Meter (583 KB)
- KCl Replenish-free ORP Sensor, OR10RP (136 KB)
- KCl Refillable ORP Sensor, OR10FP (121 KB)
一般规格书
- Model PF20, PD20 and PS20 EXA Compact pH Probes (1.3 MB)
- Model WU11 Interconnection/Extension Cable for SENCOM Products (694 KB)
- Model BA11 Active Junction Box (894 KB)
- Model SM21 Industrial pH Electrodes (740 KB)
- Model SR20 Single reference electrode (pH) (2.3 MB)
- SM60 Industrial electrodes for temperature measurement (805 KB)
- SM23 Industrial electrodes for single pNa measurement (931 KB)
- Model SC29 Industrial Redox Electrodes (930 KB)
- PH4/OR4 Sensor Series pH and ORP Sensors (718 KB)
- Model SC21 Industrial pH Electrodes (950 KB)
- pH and ORP Sensors (1.6 MB)
- *Discontinued: SENCOM FU20F / FU24F / SC25F Digital pH/ORP-sensor (3.7 MB)
- Chemical Cleaning pH Measuring System (971 KB)
- FLXA402 4-Wire Converter (1.4 MB)
- Sensor Holders (3.2 MB)
- EXAtrac Series Retractable Holder (1.0 MB)
产品图示
- PUS400G Ultrasonic Oscillator (48 KB)
MSDS/SDS
- Safety Data Sheet K1220QT / Electrolyte for individual and combined pH and ORP sensors
- K1520BK - Sodium buffer solution pH 9.00 (+/-0.02) natural (240 KB)
- K1520BG - Buffer solution NA pH 2.00 (+/-0.02) natural (254 KB)
- K1520BH - Sodium buffer solution pH4.00(+/-0.02) naturel (243 KB)
- K1520BJ - Buffer solution NA pH 7.00 (+/-0.02) natural (219 KB)
- K1520BE - Standard buffer pH 9.18 kit, yellow (233 KB)
- K1520BD - Buffer solution pH 6.87 kit, orange/yellow (231 KB)
- K1520BC - Buffer solution pH 4.01 kit, red/pink 3 x 500 ml (220 KB)
- K1520BB - Buffer solution pH 1.68 kit, green/blue 3 x 500ml (240 KB)
- K9220XE / K9084KG / K9084LM - pH7 Standard solution (165 KB)
- K9020XU / K9146CA / K9142UT - KCl powder (458 KB)
- K9020XA / Powder for buffer solution (pH4) (280 KB)
- K9220XD / K9084KF / K9084LL - pH4 Standard solution (180 KB)
- K9020XB / Powder for buffer solution (pH7) (281 KB)
- K9020XC / Powder for ph9 standard solution (251 KB)
- K9084KH, K9084LN / pH9 standard solution (189 KB)
- K9024ED / Reagent for ammonium iron sulfate solution (173 KB)
- K9220XH/ K9084KQ/ K9084KS/ K9084LP / 3.3M KCl solution (182 KB)
视频
想要了解更多的信息,技术&解决方案?
联系我们