pH electrodes and sensors are the sensing portions of a pH measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper pH electrode/sensor selection is critical for optimal measurement results.
-
All-in-One pH/ORP Sensor Series FU20 and FU24
The FU20 and FU24, all-in-one pH and ORP, sensors show how Yokogawa applies the motto "Simple is best" to sensor technology.
-
pH/ORP Sensors PH8EFP, PH8ERP, OR8EFG, OR8ERG
Yokogawa's pH and ORP analyzers are highly reliable. They feature advanced functions and are useful for a wide variety of applications including water quality management in a broad range of production processes and in medium-sized wastewater treatment plants, or as general pH and ORP control systems.
-
12mm pH Sensor SC25V
The SC25V is a pH sensor in a 12 mm design that includes an integral temperature element and a Liquid earth electrode.
-
Differential pH/ORP Sensors
The cation differential pH and ORP sensors were designed for difficult applications where conventional sensors are ineffective. These include measurements such as brine solutions to applications as diverse as electrolysis processes and cheese manufacturing.
-
Industrial pH/ORP Electrodes
The heart of a pH measuring loop is the electrode system. Yokogawa has designed a wide range of electrodes to ensure this heart keeps beating under the most severe conditions.
-
Pure Water pH and ORP Sensors
Achieving accurate and reliable readings using a traditional pH analyzer is challenging, however with the right equipment stable and accurate pure water pH measurements can be accomplished. Yokogawa's specialized bellomatic pH sensor is proven best solution for high purity water applications. For those individuals that do not like the maintenance of refilling sensors, then the FU24 which incorporates the successful patented bellow system in an All-in-one body is the ideal solution.
-
pH Sensor for High Purity Water PH8EHP
The PH8EHP pH sensor and PH8HH holder perform reliable measurement of pH for high purity water used in boilers and semiconductor process applications.
-
pH and ORP Sensors PH4/OR4 Sensor Series
PH4/OR4 pH/ORP Sensor Series Allows pH/ORP measurement under severe conditions, such as where the process fluid is heavily contaminated or contains sulfide. PH4/OR4 Sensor Series meets the simple apparatus requirements.
-
Portable pH Meter PH91, Portable pH/ORP Meter PH92
Tough, easy-to-use handheld pH/ORP meter that can be carried anywhere.
It can measure pH and ORP stably and accurately.
As your daily measurement partner. -
Personal Handheld Meter PH71/PH72
The PH71/PH72 pH and/or ORP meter is a Compact, Easy-to-use, Drip proof – Ideal for Field Use. Features "One-Touch Calibration" and Temperature Compensation. Laboratory-Grade Intelligent pH Meters – Sized and Priced to Fit in Your Pocket
-
Sensor Holders for pH/ORP, DO and MLSS Analyzers
Yokogawa provides several types of holders, for which cleaners can be added, allowing customers to build reliable and easy-to-maintain measuring systems by selecting the right holders and cleaners for the conditions of applications.
-
pH/ORP Buffer Calibration Solutions
Buffer solutions are needed as an indispensable tool for maintaining an accurate pH measurement. Buffer solutions are used as references points for calibration and adjustment of pH measurements to compensate for aging and deterioration.
-
Wide Body Sensor for Water and Wastewater PH21
The PH21 is the newest wide body sensor in the Yokogawa portfolio meant for water and wastewater market.
-
Product Finder
This web tool makes it easier to find products according to the application, measurement conditions and required specifications.
Resources
- More than 1,000 field devices designed to the PROFIBUS specifications installed in the state-of-the-art water reclamation plant.
- The high reliability and accuracy of our field devices contributes to the minimization of maintenance costs over the entire plant lifecycle.
For control of batch neutralization, a pH measurement coupled with a timer-controlled chemical feed scheme provides very satisfactory results.
This system can be adapted for either acid waste or alkaline waste neutralization.
Wet scrubbers are used in utilities, paper mills, and chemical plants to remove sulfur dioxide (SO2) and other pollutants from gas streams. Undesirable pollutants are removed by contacting the gases with an aqueous solution or slurry containing a sorbent. The most common sorbents are lime, Ca(OH)2, and limestone, CaCO3.
There are a number of suppliers of oil and fat products used for edible purposes. These products include, but are not limited to olive oil, peanut oil, soybean oil, sunflower oil, lard, shortening, butter, and margarine. The raw materials for these products include animal by-products, fleshy fruits (palm and olive), and oilseeds.
Industry:Food and Beverage
The proliferation of microorganisms and the resultant formation of slime is a problem which commonly occurs in aqueous systems. Problematic slime producing microbes may include bacteria, fungi and/or algae. Slime deposits typically occur in many industrial aqueous systems including cooling water systems, pulp and paper mill systems, petroleum operations, clay and pigment slurries, recreational water systems, air washer systems, decorative fountains, food, beverage, and industrial process pasteurizers, sweetwater systems, gas scrubber systems, latex systems, industrial lubricants, cutting fluids, etc.
Industry:Refining, Food and beverage, Power, Oil and Gas, Pulp and Paper, Chemical
One of the primary applications for high purity water is for boiler feed water. The measurement of pure water pH can be one of the quickest indicators of process contamination in the production or distribution of pure water. Effective chemical treatment of the feed water is vital in maintaining the useful operating life and minimizing maintenance costs of the boiler.
Industry:Power, Pharmaceutical, Common
Process liquid analyzers such as pH meters, conductivity meters, ORP meters, and density meters play an important role at electrolysis plants in the control of concentrations of various process solutions. This requires both precision and stability under harsh conditions that include highly corrosive substances, high temperatures, and many impurities.
The control of the world's water resource is arguably one of the most important issues. Water demand from industry and domestic users is set to rise throughout the industrialized world. Yokogawa has been applying minimized maintenance measurement systems.
Caustic soda and hydrochloric acid, produced in electrolyzer plants, are fundamental materials used in varieties of industries; chemicals, pharmaceuticals, petrol-chemicals, pulp and papers, etc. Profit is the result of the effective production with minimized running / maintenance cost. Proper control of the process brings you stabilized quality of products with the vast operational profit.
Cyanide-bearing wastewater from mining and electroplating facilities and certain types of chemical plants is toxic and must be treated by oxidation with chlorine or chloride to bring the cyanide concentration within regulatory limits.
Industry:Electrical and Electronics
In flue gas desulfurization systems that use magnesium hydroxide (Mg(OH)2) slurry, the consumption of the desulfurization agent (Mg(OH)2) is controlled by using online pH analyzers. A great concern in the pH measurement is heavy staining of the pH electrodes by the Mg(OH)2 slurry. To ensure accurate measurement, frequent cleaning of the electrodes with an acid is required, adding to both maintenance workload and cost.
Industry:Chemical, Power
The treatment of wastewater from pulp and paper plants is a serious environmental concern. Yokogawa's submersion holder with an ultrasonic+air-jet cleaner (customized product) can reduce the manual cleaning frequency to just once every one or two months.
Industry:Pulp & Paper
Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. Problems at the wet end (stock preparation) can rarely be corrected downstream. That is why monitoring and controlling pH in pulp stock is critical to the paper making process. Essentially, at every stage in the manufacture of paper, correct pH values play a vital role.
Reverse osmosis (RO) is a separation process that uses pressure to force a solution through a membrane that retains the solute on one side and allows the pure solvent to pass to the other side. More formally, it is the process of forcing a solvent from a region of high solute concentration through a membrane to a region of low solute concentration by applying a pressure in excess of the osmotic pressure.
Continuous technology improvement is ongoing in the pulp & paper industry to obtain the best possible performance. The improved plant performance translates to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.
Wastewater from electroplating facilities and certain types of chemical plants contains toxic forms of hexavalent chromium such as chromate and dichromate. The hexavalent chromium in this wastewater must be reduced before the water can be discharged. This requires a two-step process: hexavalent chromium (CR6) is reduced to trivalent chromium (CR3); and CR3 is precipitated as chromium hydroxide.
Industry:Electrical and Electronics
Sour Water is the wastewater that is produced from atmospheric and vacuum crude columns at refineries. Hydrogen sulfide and ammonia are typical components in sour water that need to be removed before the water can be reused elsewhere in the plant. Removal of these components is done by sending the sour water from the process to a stripping tower where heat, in the form of steam, is applied.
Power plant boiler houses designed to burn coal or high sulfur oil are required by Federal and State pollution regulations to "scrub" (remove) sulfur dioxide from flue gasses to meet emission limits. SO2 in flue gasses is known to be harmful to the environment, as it is one contributor to the formation of acid rain. pH control is critical for the proper functioning of the scrubber system.
Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid.
Optimizing four key factors will decrease pH sensor costs and optimize process control and overall plant efficiency.
ORP (Oxidation-Reduction Potential) is the measurement, in millivolts, of a solution's capacity for electron transfer (oxidation or reduction). ORP measurement may also be called REDOX for REDuction OXidation. The name reflects that fact that within a chemical reaction reduction and oxidation are complementary; one cannot occur without the other.
To facilitate the accurate measurement of pH, and its presentation as a scale, a range of "standard liquids" or "buffer solutions" are used. These liquids, whose constituents are accurately defined, have known stable values. Although in the preceding text the relationship to hydrogen ions has been made, research has shown, that the activity of hydroxonium ions (H30+) is more relevant.
Downloads
Brochures
- Process Analyzers Analytical Instruments and Systems Overview
- Portable pH Meter, pH/ORP Meter, Conductivity Meter (4.7 MB)
- Electrolyzer Solution Instruments and Solution for Ion-Membrane Electrolyzer Plant Application (3.4 MB)
- Liquid Analyzer Sensors and Fittings (5.9 MB)
- Model FU24 Challenging and harsh applications widebody type pH and ORP sensors (8.3 MB)
- PH71/PH72/SC72 Personal pH, pH/ORP, Conductivity Meters (1.8 MB)
- FLXA402 4-Wire Liquid Analyzer, SA11 SENCOM Smart Adapter (2.9 MB)
- Yokogawa in the water industry (17.1 MB)
Instruction Manuals
- Model PR10 Manual Retractable Fitting (5.4 MB)
- Model WU10, WF10 and WE10 - VP cable and extension cable
- Model FF20 Flow fittings Model FS20 Subassembly flow fittings Model FD20 immersion fitting (3.4 MB)
- Model SC25F pH SENCOMR sensor (1.1 MB)
- PUS400G Ultrasonic Oscillator (1.3 MB)
- Model FU24F pH/ORP SENCOMR sensor (1.3 MB)
- Solid Electrolyte (Xerolyt) pH Sensor with Temperature Element (488 KB)
- PH8ECP KCl Filling Type pH Sensor (for electrolysis plant) (566 KB)
- PH8HH pH Holder for High Purity Water (617 KB)
- PH8ERP KCl Refillable type pH Sensor (715 KB)
- PH4/OR4 Sensor Series pH and ORP Sensors (679 KB)
- SPS24 SENCOM Software (1.2 MB)
- PH4B pH Sensor for Small Culture Tank (330 KB)
- PH8AX Accessory Set for pH Meter (583 KB)
- KCl Replenish-free ORP Sensor, OR10RP (136 KB)
- KCl Refillable ORP Sensor, OR10FP (121 KB)
General Specifications
- Model PF20, PD20 and PS20 EXA Compact pH Probes (1.3 MB)
- Model WU11 Interconnection/Extension Cable for SENCOM Products (694 KB)
- Model BA11 Active Junction Box (894 KB)
- Model SM21 Industrial pH Electrodes (740 KB)
- Model SR20 Single reference electrode (pH) (2.3 MB)
- SM60 Industrial electrodes for temperature measurement (805 KB)
- SM23 Industrial electrodes for single pNa measurement (931 KB)
- Model SC29 Industrial Redox Electrodes (930 KB)
- PH4/OR4 Sensor Series pH and ORP Sensors (718 KB)
- Model SC21 Industrial pH Electrodes (950 KB)
- pH and ORP Sensors (1.6 MB)
- *Discontinued: SENCOM FU20F / FU24F / SC25F Digital pH/ORP-sensor (3.7 MB)
- Chemical Cleaning pH Measuring System (971 KB)
- FLXA402 4-Wire Converter (1.4 MB)
- Sensor Holders (3.2 MB)
- EXAtrac Series Retractable Holder (1.0 MB)
Technical Information
Certificates
Drawings
- PUS400G Ultrasonic Oscillator (48 KB)
MSDS/SDS
- Safety Data Sheet K1220QT / Electrolyte for individual and combined pH and ORP sensors
- K1520BK - Sodium buffer solution pH 9.00 (+/-0.02) natural (240 KB)
- K1520BG - Buffer solution NA pH 2.00 (+/-0.02) natural (254 KB)
- K1520BH - Sodium buffer solution pH4.00(+/-0.02) naturel (243 KB)
- K1520BJ - Buffer solution NA pH 7.00 (+/-0.02) natural (219 KB)
- K1520BE - Standard buffer pH 9.18 kit, yellow (233 KB)
- K1520BD - Buffer solution pH 6.87 kit, orange/yellow (231 KB)
- K1520BC - Buffer solution pH 4.01 kit, red/pink 3 x 500 ml (220 KB)
- K1520BB - Buffer solution pH 1.68 kit, green/blue 3 x 500ml (240 KB)
- K9220XE / K9084KG / K9084LM - pH7 Standard solution (165 KB)
- K9020XU / K9146CA / K9142UT - KCl powder (458 KB)
- K9020XA / Powder for buffer solution (pH4) (280 KB)
- K9220XD / K9084KF / K9084LL - pH4 Standard solution (180 KB)
- K9020XB / Powder for buffer solution (pH7) (281 KB)
- K9020XC / Powder for ph9 standard solution (251 KB)
- K9084KH, K9084LN / pH9 standard solution (189 KB)
- K9024ED / Reagent for ammonium iron sulfate solution (173 KB)
- K9220XH/ K9084KQ/ K9084KS/ K9084LP / 3.3M KCl solution (182 KB)
Videos
Looking for more information on our people, technology and solutions?
Contact Us