Oxidation Monitoring in the Cyanide Wastewater Treatment Process

Download (171 KB)

Oxidation Monitoring in the Cyanide Wastewater Treatment Process

Cyanide decomposition process
Cyanide decomposition process

Cyanide-bearing wastewater from mining and electroplating facilities and certain types of chemical plants is toxic and must be treated by oxidation with chlorine or chloride to bring the cyanide concentration within regulatory limits. The waste materials contain alkaline, rare earth metals, and other heavy metals such as iron, nickel, zinc, cadmium, copper, silver and gold. As well as sometimes can contain the deadly poison, cyanide. As the speed of the oxidation reaction is closely tied to the pH value, a pH analyzer is used together with an ORP (oxidation-reduction potential) analyzer to monitor the completion of the reaction. The use of these analyzers also ensures that excessive amounts of chemicals (e.g., chlorine) are not used to produce the reaction. Both 2-wire and 4-wire analyzers are suitable for this measurement system. A gold electrode should be used for ORP measurement of cyanidecontaining solutions.

Expected Benefits

  • Measures pH/ORP of cyanide wastewater continuously
  • Reduces operating costs

Process Overview

Measurement of ORP

Cyanide decomposition takes place in two stages. In the primary reaction, cyanide is oxidized to cyanate under high alkaline conditions (high pH and ORP). In the first reaction tank, the pH of the waste is measured and caustic (NaOH at 50% strength) is injected to raise the pH to 10 or higher. The oxidation reduction potential (ORP) of the waste is measured, and chlorine gas (Cl2) is automatically injected to raise the ORP to 400 mV or higher. The reaction normally occurs within 5 to 10 minutes.

In the secondary reaction, the cyanate is further oxidized under near-neutral conditions and converted to harmless carbon dioxide and nitrogen gases. In the second reaction tank, the pH of the waste is measured, and acid is injected to lower pH to 7-8. This process takes 2 to 5 minutes. In the third reaction tank, the ORP of the waste is measured and chlorine gas (Cl2) is automatically injected to raise the ORP to 600 mV or higher (Meanwhile the pH controller maintains the set-point at 7-8, correcting for any acidity created by the addition of the chlorine gas). This reaction occurs, taking 10 to 15 minutes, then the cyanide is eventually converted to harmless materials by the above reaction and the waste can be discharged.

 

  

Solution Details

Measurement system
2-wire/4-wire ORP measurement system
2-wire/4-wire pH measurement system
Sensor
KCl refillable ORP sensor: OR8EFG-AU-☐☐-TT1-☐*A
KCl refillable pH sensor: PH8EFP-☐☐-TN-TT1-N-☐*A
Submersion type holder: PH8HS-PP-☐☐-T-NN-NN*A
Terminal box (when needed)
WTB10-PH1 (for 2-wire system)
WTB10-PH3 (for 4-wire system)
Converter/transmitter:
2-wire transmitter (pH/ORP): PH202G-E-E
4-wire pH/ORP converter: PH450G-A-☐
Distributor (for 2-wire system): PH201G- A☐*B

Measurement Conditions

A gold electrode should be used to ensure accurate measurement of ORP in cyanide solutions. When the potential is near or under 200 mV during the cyanide oxidation process, a platinum electrode produces a catalytic reaction that causes hydrogen to form on the electrode surface. This generates potential and affects measured values.

pH and ORP levels in this area can be simultaneously monitored with the PH450 pH/ORP Analyzer. The model PH450 pH/ORP Analyzer performs continuous sensor diagnostics to notify the user when the sensor is coated or the glass electrode has broken.

The PH20 "Tempress" sensor with has a 3/4" NPT threads is convenient to install and use in the reaction tanks. Adapters enable it to be converted into a 1" MNPT thread, as well as a flow thru assembly or direct insertion assembly with a cleaning system. This sensor features four separate elements (pH, reference, temperature, ORP) in a rugged PVDF body. The integral number-coded cable and integral NPT threads allow for easy and convenient installation. When used with PH4050 or PH202 pH/ORP Analyzers, it can give simultaneous measurements of pH and ORP is possible with one sensor.

Utilities

PH202G
Power supply: 17 to 40 V DC (from distributor)
PH450G
Power supply: 96 to 264 V AC, 50/60 Hz
Power consumption: approx. 15 VA
PH201G distributor
Power supply:

100 V: 20 to130 V DC/80 to 138 V AC, 47 to 63 Hz

220 V: 120 to 340 V DC/138 to 264 V AC, 47 to 63 Hz
Power consumption: 24 V DC: approx. 200 mA
100 V AC: approx. 7 VA
220 V AC: approx. 11 VA

Industries

Related Products & Solutions

2-Wire Transmitter/Analyzer FLXA202/21

The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.

4-Wire pH/ORP Analyzer PH450

The PH450 pH and ORP analyzer is a multivariable analyzer that combines pH with temperature and ORP (Redox) measurement, which can be utilized through different output functions: two mA current outputs, four independent SPDT contact outputs and HART. 

All-in-One Digital Smart pH/ORP Sensor FU20F

All-In-One pH and ORP digital SMART sensor that keeps the motto "Simple is best" while combing the sensor with built-in intelligence and direct digital communication. 

All-in-One pH/ORP Sensor Series FU20/FU24/PH20

The PH20, FU20 and FU24, all-in-one pH and ORP, sensors show how Yokogawa applies the motto "Simple is best" to sensor technology.

Flow/NPT Fittings FF20/FS20

Yokogawa has invested considerable design and development time in producing a full range of fittings with particular emphasis on designs that reduce installation and maintenance time and consequently save operation costs.

Four-Wire Conductivity Analyzer

The EXAxt450 series covers all Conductivity Applications including all special software functions in the standard analyzers to reduce the number of configurations. This results in less inventory and less training needs for users that have multiple Conductivity applications.

pH/ORP Sensors PH8EFP, PH8ERP, OR8EFG, OR8ERG

Yokogawa's pH and ORP analyzers are highly reliable. They feature advanced functions and are useful for a wide variety of applications including water quality management in a broad range of production processes and in medium-sized wastewater treatment plants, or as general pH and ORP control systems.

pH and ORP Analyzers

pH and ORP meters, analyzers and transmitters are used for continuous process monitoring of pH and ORP to ensure water/product quality, monitor effluent discharge, batch neutralization, pulp stock, scrubbers, cooling towers, chemical, water/wastewater treatment and many other applications.

pH and ORP Sensors

pH electrodes and sensors are the sensing portions of a pH measurement. Various installation options including retractable, flow thru, immersion, and direct insertion. Proper pH electrode/sensor selection is critical for optimal measurement results.

×

Have Questions?

Contact a Yokogawa Expert to learn how we can help you solve your challenges.

Top