Oxidation Monitoring in the Cyanide Wastewater Treatment Process
Cyanide-bearing wastewater from mining and electroplating facilities and certain types of chemical plants is toxic and must be treated by oxidation with chlorine or chloride to bring the cyanide concentration within regulatory limits. The waste materials contain alkaline, rare earth metals, and other heavy metals such as iron, nickel, zinc, cadmium, copper, silver and gold. As well as sometimes can contain the deadly poison, cyanide. As the speed of the oxidation reaction is closely tied to the pH value, a pH analyzer is used together with an ORP (oxidation-reduction potential) analyzer to monitor the completion of the reaction. The use of these analyzers also ensures that excessive amounts of chemicals (e.g., chlorine) are not used to produce the reaction. Both 2-wire and 4-wire analyzers are suitable for this measurement system. A gold electrode should be used for ORP measurement of cyanide-containing solutions.
Expected Benefits
- Measures pH/ORP of cyanide wastewater continuously
- Reduces operating costs
Cyanide decomposition process
Process Overview
Cyanide decomposition takes place in two stages. In the primary reaction, cyanide is oxidized to cyanate under high alkaline conditions (high pH and ORP). In the first reaction tank, the pH of the waste is measured and caustic (NaOH at 50% strength) is injected to raise the pH to 10 or higher. The oxidation reduction potential (ORP) of the waste is measured, and chlorine gas (Cl2) is automatically injected to raise the ORP to 400 mV or higher. The reaction normally occurs within 5 to 10 minutes.
In the secondary reaction, the cyanate is further oxidized under near-neutral conditions and converted to harmless carbon dioxide and nitrogen gases. In the second reaction tank, the pH of the waste is measured, and acid is injected to lower pH to 7-8. This process takes 2 to 5 minutes. In the third reaction tank, the ORP of the waste is measured and chlorine gas (Cl2) is automatically injected to raise the ORP to 600 mV or higher (Meanwhile the pH controller maintains the set-point at 7-8, correcting for any acidity created by the addition of the chlorine gas). This reaction occurs, taking 10 to 15 minutes, then the cyanide is eventually converted to harmless materials by the above reaction and the waste can be discharged.
Solution Details
Measurement system | |
---|---|
2-wire/4-wire pH/ORP measurement system | |
Sensor/Holder | |
KCl refillable ORP sensor: | OR8EFG-AU-☐☐-TT1-☐*A |
KCl refillable pH sensor: | PH8EFP-☐☐-TN-TT1-N-☐*A |
Submersion type holder: | PH8HS-PP-☐☐-T-NN-NN*A |
Terminal box (when needed) | |
WTB10-PH1 (for 2-wire system) | |
WTB10-PH3 (for 4-wire system) | |
Analyzer/converter: | |
2-wire pH/ORP analyzer (pH+ORP2 input): | FLXA21-D-P-S-☐☐-P1-P1-A-N-LA-N FLXA202-D-B-D-☐☐-P1-P1-A-N-LA-N-NN |
Distributor (for 2-wire system): | PH201G- A☐*C |
4-wire pH/ORP converter (pH+ORP 2 input): | FLXA402-☐-B-☐☐-P1-P1-A2-WR-☐-☐-N-NN |
Utilities
FLXA21/FLXA202 | |
---|---|
Power supply: | 23 to 40 V DC (from distributor) |
FLXA402-A | |
Power supply: | 90 to 264 V AC, 50/60 Hz |
Power consumption: | approx. 35 VA |
FLXA402-D | |
Power supply: | 10.8-26.4 V DC |
Power consumption: | approx. 15 W |
Measurement Conditions
- Cyanide curve measured with chlorine [Measurement of water with a ph value of 9 using a gold electrode (as the indicating electrode) and an Ag/AgCl electrode with 4 mol (as the reference electrode)] Oxidation reaction of CN- with Cl2 exhibits a characteristic curve that is not ideal (see the figure on the right). This is because firstly an excessive amount of chlorine increased the plateau potential of the intermediate, cyanogen chloride to 500 to 600 mV, and secondly oxidation reaction started in the secondary reaction tank to form CNO-, resulting in a decrease in CIO- and stopping the potential from increasing.
- Using a gold electrode as the indicating electrode for ORP measurement A gold electrode should be used to ensure accurate measurement of ORP in cyanide solutions. When the potential is near or under 200 mV during the cyanide oxidation process, a platinum electrode produces a catalytic reaction that causes hydrogen to form on the electrode surface. This generates potential and affects measured values.
產業別
-
Water & Wastewater
促進永續水循環是永續發展目標(SDG)之一。 橫河電機一直致力於提供先進的數位控制解決方案,以穩定供應清潔安全的水、保護水環境的廢水處理、水損耗管理以及優化工廠運作減少二氧化碳排放和運行成本。 利用我們領先的技術、可靠的產品以及在世界各地不同供水項目中豐富的專業知識和經驗,我們與客戶合作提供可持續的水務解決方案,以促進客戶的業務並在整個工廠生命週期中增加價值。
橫河電機支援公用和工業用水的各種供水控制應用。
相關產品&解決方案
-
Flow/NPT Fittings FF20/FS20
Yokogawa has invested considerable design and development time in producing a full range of fittings with particular emphasis on designs that reduce installation and maintenance time and consequently save operation costs.
-
FU20/FU24/PH20一體化pH/ORP (REDOX)傳感器
PH20/FU20/FU24一體化pH/ORP傳感器體現了橫河電機如何將“簡單即好”這句格言應用於傳感器技術。
-
PH8EFP、PH8ERP、OR8EFG、OR8ERG pH/ORP傳感器
橫河電機的pH/ORP分析儀可靠性很高,具有多種先進功能且應用廣泛,包括在一系列生產製程和中型廢水處理廠中進行水質管理,或者用作通用的pH/ORP控制系統。
-
兩線式Dual Channel分析儀 FLXA21
FLEXA™ 系列分析儀用於工業裝定的連續線上測量,具有單感測器或雙感測器測量選項,是目前最靈活的兩線式分析儀。
-
兩線式液體分析計FLXA202
FLEXA™ 系列分析儀用於工業裝定的連續線上測量,具有單感測器或雙感測器測量選項,是目前最靈活的兩線式分析儀。
-
四線式液體分析計 FLXA402
The FLEXA™ 系列分析計是模組化設計的分析計,用於工業裝定中的連續線上測量。提供單一或多sensor測量。
-
數位 SMART SENCOM™ 轉接器: SA11
可重複使用的 SMART 轉接器,只需在感測器達到其使用壽命時進行處理。橫河電機的SENCOM 4.0平台,可降低營運成本和資源浪費,同時貢獻永續未來的長期業務目標。
-
pH和ORP傳感器
pH電極和傳感器是進行pH值測量的傳感部分,有伸縮式、流通式、浸入式和直插式等多種安裝選項。選擇合適的pH電極/傳感器對優化測量結果至關重要。