The NR800 Near Infrared Analyzer achieves high-resolution, high S/N (signal-to-noise) ratio, and wide wavelength scanning range measurement with its newly developed interferometer and detector. The NR800 also offers exceptional stability, vibration resistance, and durability, inheriting features from earlier successful models. It includes improved usability features such as measurement channel and output configuration as well.

The NR800 allows online, real-time, continuous, multiple, and simultaneous measurement for properties and component concentration of various processes.

   Bulletin for NR800
   General Specification for NR800 
   General Specification for NR800 MODBUS Communication 

   Click here to request a technical document for Near Infrared Analyzers

Features

* Newly developed high performance interferometer and detector.
* Enhanced environmental resistance, durability, and reliability.
* Outstanding wavelength accuracy allows calibration model transport between NR800s.
* Outlier detection and self-diagnostic features come as standard function.
* Various standard features and available options for optimal system configuration.

Specifications

Location Hazardous/non-hazardous area, indoor/outdoor.
Avoid direct exposure to wind and rain, sunlight or radiation heat.
Principle Fourier-transform Near Infrared analyzer via fiber-optic cable, Double beam
Measurement method Optical transmission absorption
Detector InGaAs (Indium Gallium Arsenide)
Light source Halogen lamp
Wavelength range 900 to 2500 nm
Wavelength accuracy 0.04 cm-1
Wavelength repeatability 0.007 cm-1
Wavelength resolution 4, 8, 16, 32, 64 cm-1 selectable
Number of channel Max. 4 channels with no optical multiplexers
Number of measurement Max. 12 per channel (Max. 64 per analyzer)
Measurement time 4 seconds as minimum(depending on the number of averaging and measuring channels, as well as measurement items)
Communication interface Engineering PC: 1 channel (Ethernet)
DCS/, I/O unit: 2 channels (RS-422, Modbus)
Contact output Two points; Purge failure, analyzer failure
Enclosure General purpose type:
  Model NR801AG; CSA standard
  Model NR801EG; With CE mark
  Model NR801JG; Japanese version
Explosionproof type:
  Model NR805AG; Type X purging, FM approved, Suitable for Class I,
          Division 1,Group B, C,and D. Temperature class T5.
          NEPSI certified, Suitable for Ex pxd II B+H2 T5
  Model NR805EG; ATEX(CENELEC) certified, Suitable for EEx pd B+H2
          T5, With CE mark
          NEPSI certified, Suitable for Ex pxd IIB+H2 T5
  Model NR805JG; TIIS certified, Suitable for TIIS Expd II B+H2 T5
Power supply 100, 115, 200 or 230 V AC ±10 %, 50/60 Hz; consumption:approx. 250 VA
Environment temp., RH -10 to 40℃, 0 to 95 % RH
Weight General-purpose model: Approx. 50 kg
Explosion-proof model: Approx. 65 kg

Performance

Wavelength scanning range 900 to 2500 nm (11,000 to 4000 cm-1)
Wavelength resolution 4, 8, 16, 32, and 64 cm-1 (user selectable)
Wavelength reproducibility 0.007 cm-1
Wavelength accuracy 0.04 cm-1
S/N ratio 500:1 (peak to peak, 4100 to 4200 cm-1, 1 sec.)