US300FM Performance
|
Fluid
|
Liquid with turbidity < 10,000 mg/litter, fluid sound velocity 800 to 3,500 m/s)
|
|
Measured values
|
Volume flow, mass flow (by setting density), flow velocity, sound speed in fluid (when optional wall thickness probe is provided)
|
|
Pipe size
|
25 to 6,500 mm
|
|
Pipe material
|
Carbon steel, stainless steel, gray cast iron, ductile iron, copper, glass, PVC, etc.
|
|
Flow velocity range
|
0.01 to 25 m/s
|
|
Fluid temperature range
|
-30 deg to +130 deg C. (general use)
-30 deg to +200 deg C. (high-temperature use)
|
|
Accuracy
|
1% to 3% of reading (depends on application)
|
|
Straight pipe run upstream
|
More than 10 D (depends on the piping conditions)
|
Main unit construction
|
Housing material
|
Aluminum (powder coated)
|
|
Water/dust proof
|
IP65
|
|
Dimensions (HxWxD)
|
200 mm x 280 mm x 71 mm
|
|
Weight
|
Approx. 2.8 kg
|
Transducer construction
|
Case material
|
Stainless steel SUS316 Ti
|
|
Water/dust proof
|
IP65 (General purpose), IP67 (Immersible)
|
Functions
|
Calculation of the two flow inputs
|
Two values from an average (for two path measurement), sum, or difference for channel A and channel B inputs
|
|
Time-programmable measurement
|
Automatic start and stop of measurement using internal clock. Can be used with data logging or communication function.
|
|
Parameter setting storage
|
Storage of pipe and fluid parameters (Maximum of 80 different settings)
|
|
Sound velocity measurement
|
Measurement of the sound velocity in the liquid
|
|