Introduction
In a semiconductor plant, a variety of chemicals are used in various manufacturing processes. The chemicals used for specific purposes are produced by diluting raw liquid with demineralized water using in diluting equipment, and the control of the concentration at this point is performed by conductivity measurement. The FLXA202 and FLXA402 Inductive Conductivity Analyzer are capable of high-precision measurement, and their toroidal probe ISC40 is sealed in rugged PEEK (Poly Ether Ether Ketone) material to withstand the harshest applications. A highly reliable measurement is achieved by using FLXA202/FLXA402 in the control of concentrations of chemicals in a dilution system. The FLXA202 and FLXA402 Inductive Conductivity Analyzer also play a role in the drainage control and the processing of solutions delivered from various manufacturing processes.

Dilution System Diagram
Expected Benefits
- Easy control of fluoric acid concentration
- Reduces operating costs
- Establishment of corrosion-resistant wetted parts
Process Overview
Up to now, chemicals used in semiconductor plants have been purchased in concentrations diluted beforehand by the chemical company to suit specific applications. However, as the price competition in the semiconductor market is increased, the operating cost reduction is highly required. As a result, each chemical used in a manufacturing process has been reviewed so that the substance profits and widespread cost reductions are secured.
Ordering chemicals in various concentrations from chemical manufacturing companies has been replaced by the installation of dilution systems at individual companies, whereby a raw chemical solution, whose price is not significantly different from that of diluted chemicals, is diluted to the required concentration, using inexpensive demineralized water.
Solution Details
| Measurement system | |
|---|---|
| 2-wire inductive conductivity system | |
| Sensor | ISC40G-TG-T1-☐☐ |
| Flow-through type holder | ISC40FF-☐A |
| Analyzer | FLXA202-D-BーD-AB-C5-NN-A-N-LA-☐-NN |
| Dedicated distributor for transmitter | PH201G-A☐*C |
| 4-wire inductive conductivity system | |
| Sensor | ISC40G-TG-T1-☐☐ |
| Flow-through type holder | ISC40FF-☐A |
| Converter | FLXA402-A-B-□-C5-NN-A2-WR-☐-☐-☐-NN |
Field Data

Measurement Examples
Utilities
| FLXA202 2-wire inductive conductivity analyzer | |
|---|---|
| Power supply voltage: | 17 - 40 V DC (from distributor) |
| PH201G distributor | |
| Power supply: | 100 V: 20 to130 V DC/80 to 138 V AC, 47 to 63 Hz |
| 220 V: 120 to 340 V DC/138 to 264 V AC, 47 to 63 Hz | |
| Power consumption: | 24 V DC: approx. 200 mA |
| 100 V AC: approx. 7 VA | |
| 220 V AC: approx. 11 VA | |
| FLXA402 4-wire inductive conductivity converter | |
| Power supply: | 90 to 264 V AC, 50/60 Hz |
| Power consumption: | 35 VA maximum |
相關產品&解決方案
-
兩線式Dual Channel分析儀 FLXA21
FLEXA™ 系列分析儀用於工業裝定的連續線上測量,具有單感測器或雙感測器測量選項,是目前最靈活的兩線式分析儀。
-
兩線式液體分析計FLXA202
FLEXA™ 系列分析儀用於工業裝定的連續線上測量,具有單感測器或雙感測器測量選項,是目前最靈活的兩線式分析儀。
-
四線式液體分析計 FLXA402
The FLEXA™ 系列分析計是模組化設計的分析計,用於工業裝定中的連續線上測量。提供單一或多sensor測量。
-
導電度分析儀
可測量自來水、污水等水質,以及各種製程液體的導電度和電阻率測量。另有衛生型及方便型可供選擇。
-
導電度感測器
導電度感測器與電極用於測量製程導電度、電阻率、WFI、去離子水、反滲透水、濃度百分比、鍋爐排污水及總溶解固體(TDS)。提供多種安裝方式,包括可伸縮型、流通型、浸入型及直接插入型。選擇合適的電極或感測器對取得最佳測量結果至關重要。
-
感應式(環形、無電極)導電率感測器 ISC40
ISC40 型感測器專為搭配 FLEXA ISC 分析儀使用而設計。此組合在可靠性、精確度、量程範圍及價格效益方面,均超越導電率測量的所有預期。