Trace Moisture in Chlorine Production

下载 (139 KB)

Rapid Detection of Moisture in Chlorine Processing

Plant Name:    North American Electrolysis Plant

Industry:          Chemical

Product(s):      Chlorine

Application

Figure 1 - Trace moisture levels in ChlorineChlorine is used as an intermediate chemical in the production of high-demand products such as bleach, acids, and PVC. To achieve the quality required for each product, chlorine manufacturers know the importance of measuring moisture levels in the chlorine gas at key points as it moves through the process toward liquefaction. 

Electrolysis plants create hydrogen and chlorine from a brine solution. Chlorine gas generated from the anolyte of the electrolysis tank generally contains between 0.5 to 2.0 vol% H2O (figure 1). The sample is then cooled and filtered to remove brine, subsequently emerging as wet chlorine gas. The wet gas flows to a drying tower where it is treated with sulfuric acid to reduce the moisture content down to ppm levels. Acid mist remaining in the dry chlorine gas flows to a dry chlorine tower where it is removed. The dry chlorine gas is then sent to a reciprocating compressor for liquefaction. 
 

Challenges

Learning immediately if there is ineffective drying or ingress of moisture into the process is critical to safe and smooth operation. For example, the presence of even trace levels of moisture after the dry chlorine tower causes corrosion of the chlorine compressor and contaminates the product with chlorine hydrate and hydrous iron chloride. When a specified level of corrosion is detected, the process must be shut down to correct these issues.

Since manufacturers must respond rapidly to the presence of moisture, they rely on sensors for alerts. A conventional moisture sensor with a range of 1-5 ppm could have a T90 response time of an hour (note: T90 is the amount of time it takes for the sensor to measure 90% of the maximum analyte level). After measuring moisture in the process, the conventional sensor must recover quickly to allow it to recognize another event. Due to sensor saturation, recovery time from large concentration spikes of moisture can take more than 24 hours. A slow-recovery sensor could miss the presence of additional moisture and lead to further contamination and corrosion. 

If a sensor is not operating, the manufacturer cannot detect moisture in the chlorine and must stop the process. Unfortunately, sensors can deteriorate and deliver inaccurate measurements due to contact with the process. This deterioration leads to maintenance costs that are associated with recalibrating or replacing the sensor. 

 

Solution

To maximize chlorine production, manufacturers need to prevent corrosion of equipment and increase the time between shutdowns. To support safe and continued chlorine production, Yokogawa’s TDLS8000 Laser Analyzer responds accurately to low quantities (in ppm) of moisture, recovers quickly after a moisture detection event, and simplifies maintenance. Since it uses solid-state electronics, the sensor will not drift and will not require re-calibration.

The TDLS8000 can respond to single-digit ppm step changes and recover from the presence of moisture in as fast as one second. Since the sensor does not contact the process, it does not degrade and will provide accurate readings over a longer period of time than conventional sensors; therefore, manufacturers are alerted more reliably to immediate, potential issues.

Since device design is modular and provides isolation from the process, maintenance is greatly simplified. In an extreme event such as a lightning strike or contaminated gas purge, any part of the TDLS8000 can be serviced or repaired in the field. For added ease, all modular components are automatically detected by the analyzer and no additional configuration is required.

In addition to measurement, the TDLS8000 Laser Analyzer assists in troubleshooting by storing 50 days of spectral data and diagnostics. This enables manufacturers to review spectral images and attain positive verification that an event was caused by moisture and not an analyzer fault. This information can be conveniently accessed via a USB flash drive, remotely via a network, or through the HMI.

 

Key Advantages

•    High sensitivity in the sensor enables users to address process issues more quickly. Minimum range is 0-30 ppm H2O. TDLS8000
•    The sensor’s rapid recovery times enable faster corrective action to address moisture issues.
•    Since the sensor does not drift, maintenance and shutdown costs are substantially reduced.
•    TDLS is a non-contacting measurement that never requires calibration or consumables.
 

行业

  • 化工

    化工厂依靠连续和批量的生产过程,每个生产过程对控制系统都有不同的要求。连续的过程需要一个强大而稳定的控制系统,该系统不能因为自身失效而导致生产线关闭;批量过程的重点在于拥有一个可以灵活调整公式程序的控制系统。两种系统都需要在产品质量记录中进行管理,并且能够执行非常规操作。横河电机凭借广泛的产品组合、经验丰富的系统工程师、遍及全球的销售和服务网络,为每个工厂流程提供解决方案。

    更多
  • 基础化工

    我们一直服务于全球大宗化工市场,在这个市场上被公认为领先者。凭借产品、解决方案和行业专业知识,横河电机了解您的市场和生产需求,并将与您合作,在您的工厂生命周期内提供可靠、经济的解决方案。

     

    更多
  • 大宗石油化工

    无论是生产石化产品、无机物还是中间产品,化工企业都面临着成本和利润率的压力,必须及时有效地交付产品,同时保持安全合规运营。此外,化工企业必须应对原料和能源价格的波动,并为市场提供性价比最高的产品组合。

     

    横河电机长期服务于全球大宗化工市场,得到大家的广泛认可通过我们的产品、解决方案和行业专业知识,横河了解您的市场和生产需求,并将与您合作,在您的工厂生命周期提供可靠、经济的解决方案。

    更多
  • 石化

    石化公司的需求极为多样繁杂。为了在当今竞争激烈的市场中脱颖而出,生产企业必须努力提高质量和生产力。横河电机在石化领域长期耕耘具有广泛的经验,我们可以为客户的需求提供量身定制的解决方案。

     

     

    更多

相关产品&解决方案

  • TDLS8000在线气体分析仪

    横河电机的新TDLS™8000功能强大,将诸多先进工业特性集成于一台耐用设备中。其平台设计适用于现场测量,无需进行样品抽取和样品处理。

    更多
  • 氧气浓度计

    氧气浓度计为燃烧控制、过程质量、安全和环境应用提供了有价值的测量数据。

    更多

置顶
WeChat QR Code
横河电机(中国)有限公司