Spheroid Analysis

下载 (584 KB)

Introduction

The structures and functions of cells produced through spheroid formation are known to be more similar to live bodies than monolayer 2D organisms. Therefore, various formation methods and data accumulation for spheroids is progressing. We imaged spheroids using CellVoyager CV7000, and analyzed the images. Specifically, multiple images were captured along the Z-axis, reorganized into 2D image data*, and evaluated with regard to the maximum spheroid diameter and number of contained cells. In this way, combination of the CV7000 high-speed 3D imaging and projection functions facilitates the efficient analysis of 3D samples. Furthermore, the method can be applied to live cells to establish new experimental methods such as the time series evaluation of cells.
※Reorganized using the maximum intensity projection (MIP) function.

Original image

Fig. 1 (a): Original image
12 images were taken at 10 µm intervals in the Z-axis direction and displayed using MIP (a’) is the magnified section.

Large image

Recognition image

Fig. 1 (b): Recognition image
Spheroid contour (purple) and contained cells (blue) in image (a) recognized using analysis software (b’) is the magnified section.

Large image

Tile image

Fig. 2(a): Tile image(25 tiles) of the entire well including 50-pixel overlapping regions between adjacent tiles in the XY direction

Large image

Tile image

Fig. 2(b): Image created by combining the tile images in (a)

Large image

Experimental

  1. HeLa cells, in which Azami-Green was expressed, were inoculated in spheroid formation dishes (EZSPHERE®, AGC Techno Glass Co., Ltd.) (5×105 cells/dish) and cultured for seven days.
  2. Spheroids were collected, fixed, and inoculated again on 96-well plates. Images were captured using the CV7000 under the following conditions:
    ・Magnification: 10x (dry)
    ・Wavelength: 488nm
    ・Exposure time: 250msec
    ・12 images taken at 10µm intervals in the Z-axis direction over a distance of 110µm
    ・Images captured per plate: 25
     (The entire well was captured using the tile function; time required per well was approx. 1.5 minutes.)
  3. The maximum spheroid diameters and the number of contained cells in the MIP image were measured using the analysis software, and graphs were created using Spotfire®.

Experiment

 

Results and Conclusion

EZSPHERE® has fine pores on the cultivation surface, which is coated with a special polymer that is non-adhesive for cells. Inoculated cells, therefore, form uniform spheroids in the wells. Six types of dishes with wells of different diameters and depths (4,000-900, -901, -902, -903, -904, -905) were used to form spheroids, and images were captured and analyzed using the CV7000. As a result, the data obtained for the maximum spheroid diameters and the number of contained cells correlated with the sizes of spheroids predicted from the diameters and depths of the wells. In this way, the CV7000 allows for efficient evaluation even for 3D samples such as spheroids.

): Tile image of each well (numbers in the images are the model

Fig. 4 (a): Tile image of each well (numbers in the images are the model numbers of used dishes.)
900 (diameter: 500µm/ depth: 100µm), 901 (diameter: 200µm/ depth: 100µm)
902 (diameter: 500µm/ depth: 200µm), 903 (diameter: 800µm/ depth: 300µm)
904 (diameter: 800µm/ depth: 400µm), 905 (diameter: 1,400µm/ depth: 600µm)

 

Spheroid diameter

Fig. 4 (b): Spheroid diameter

Number of contained cells

Fig. 4 (c): (c) Number of contained cells

Spotfire® is a registered trademark of TIBCO Software Inc.


Our Social Medias

We post our information to the following SNSs. Please follow us.

  Follow us Share our application
•Twitter @Yokogawa_LS Share on Twitter
•Facebook Yokogawa Life Science Share on Facebook
•LinkedIn Yokogawa Life Science Share on LinkedIn

 

Yokogawa's Official Social Media Account List

Social Media Account List


相关产品&解决方案

  • CellPathfinder

    CellPathfinder is designed for our HCA systems, CQ1 and the CellVoyager series. From beginners to experts, the analysis software lets you quantify subtle physiological changes and even label-free samples with various graph options.

    更多
  • CV8000高内涵筛选系统

    CellVoyager CV8000是先进的高内涵筛选系统。改进的内置培养箱可以让客户分析长期的活细胞反应。凭借其可扩展性、4个摄像机、5个激光器和可选的内置移液器,该系统允许日益复杂的分析开发和高内涵筛选。

    更多
  • 生命科学

    横河电机的高含量分析系统和双转盘共聚焦技术提供了高速、高分辨率的活细胞成像,引导了全球行业前沿的研究。

    更多
  • 高内涵分析

    我们的高内涵分析系统利用强大的分析软件解决从基础科学到药物发现筛选的一系列研究应用。

    更多

置顶
WeChat QR Code
横河电机(中国)有限公司