说明: 本产品于2016年11月30日停止生产。
查看替代产品:
The IR100TA and IR100A, dedicated for analysis of either CO2, CO, or CH4, the IR100TB and the IR100B, dedicated for simultaneous analysis of CO2 and CO, are available. The analyzers are easy to maintain and works steadily over long periods.
The ideal application of these analyzers are continuous measurement for the control and monitoring of combustion in various industrial furnaces as well as continuous measurement for the study of plants.
- Two available models: simultaneous dual-gas (CO and CO2) measurement model and single-gas dual-range measurement model
- Stable operation over long periods
- Influenced less by presence of another interfering gas
- Easy maintenance
- Wide variety of additional functions: self-diagnosis, simple calibration, automatic calibration, remote switching of the measuring range, and range identification
Specifications
Models |
|
||||||||
Measuring principle | Non-dispersive infrared absorption, deflection method, single infrared-source, single-flux (single-beam) | ||||||||
Measured gas | CO2, CO, CH4 | ||||||||
Sample gas conditions | Flowrate: 0.5 to 1 l/min Pressure: 500 Pa or more Temperature: 0 to +50℃ Dust: 100μg/Nm3 with the particle size of 1μm or less Mist: none Humidity: Avoid concentration.
|
||||||||
Measuring gas component and measuring range |
|
||||||||
Output signals | Output 1: 0 to 1 V DC, non-isolated, linearized output signals Output 2: 4 to 20 mA (maximum allowable load resistance: 550 Ω), simultaneous, non-isolated, linearized signals |
||||||||
Ambient temperature | -5 to 45℃ | ||||||||
Ambient humidity | 90%RH or less | ||||||||
Installation | Indoor | ||||||||
Weights | Approx. 12 kg | ||||||||
Power supply | 100 V AC, 115 V AC, 220 V AC(±10%)、50/60 Hz |
Performance
Repeatability | ±0.5% FS for the primary range (lower range) ±1% FS for the secondary range (higher range) |
Zero drift | ±2% FS/week |
Span drift | ±2% FS/week |
Response time (90% response) |
15 seconds or less including the time required for substitution of the sample cell |
Applications
Blast furnace | CO; 0 to 40% CO2; 0 to 30%, 0 to 40%, 0 to 50% |
Converter furnace | CO; 0 to 100% CO2; 0 to 100% |
Electric furnace | CO; 0 to 100% CO2; 0 to 100% |
Coke oven | CO; 0 to 100% CO2; 0 to 100% |
Cement kiln | CO; 0 to 1%, 0 to 5% |
Coal kiln | CO; 0 to 1%, 0 to 5% |
Carbonizing furnace | CO2; 0 to 1%, 0 to 2% |
Transforming furnace | CO2; 0 to 0.5%, 0 to 1% |