Measuring the Electric Conductivity by use of Clean-in-Place (CIP) System

下载 (266 KB)

Introduction

In the manufacturing process of Pharmaceutical, Chemical and Food & Beverage industries, the cleaning and sterilization of tanks and piping are done with various cleaning solutions, fresh or hot water and steam after manufacturing products. Clean- In-Place (CIP) is the system designed for automatic cleaning and disinfecting. The recovery of cleaning solutions contributes significantly to reduce chemical costs and wastewater processing costs.

Yokogawa FLXA21 inductive conductivity transmitter has earned a reputation in the recovery of cleaning solutions because it can take measurements with good boundary surface precision over a wide range.

CIP Process Flow

CIP Process Flow

Expected Benefits

  • Optimizes cleaning and sterilizing application for tanks and piping by use of CIP
  • Reduces operating costs

Process Overview

Inductive Conductivity SensorCIP systems depend on the process differentiations of Pharmaceutical, Chemical and Food & Beverage. In addition, the cleaning solutions and chemicals are different. The chemicals that are generally used are hypochlorous acid, caustic soda, and nitrous acid. In a cleaning solution recovery system, the process lines and piping are cleaned with an initial cleaning solution. After that, the cleaning solution is cleaned with fresh water. The cleaning solution is recovered at that point, but since it gradually becomes diluted with fresh water, recovery is discontinued and the solution is discharged through a drainage line when the concentration of the cleaning solution drops below the standard value. The cleaning with different solutions or fresh water, the recovery of the cleaning solution, and the discharge of waste solution are repeatedly carried out. In addition, sterilization with steam or cleaning with distilled water or de-ionized water is performed as a final step in some cases.

Solution Details

Measurement system
2-wire inductive conductivity system
Sensor ISC40G(J)
Flow-through type holder ISC40FF(J)
Transmitter ISC202G-A-E
Dedicated distributor for transmitter PH201G-A☐*B

Utilities

ISC202G inductive conductivity transmitter
Power supply voltage: 17 - 40 V DC (from distributor)
Power consumption: 0.9 VA maximum
PH201G distributor
Power supply: 100 V: 20 to130 V DC/80 to 138 V AC, 47 to 63 Hz
220 V: 120 to 340 V DC/138 to 264 V AC, 47 to 63 Hz
Power consumption: 24 V DC: approx. 200 mA
100 V AC: approx. 7 VA
220 V AC: approx. 11 VA

Notes

Temperature range of transmitter is -20 to 140°C

Field Data

1. Process Conditions

  Concentration (%) Temperature (°C) Pressure MPa
Water - 4 to 20 0 to 1
NaOH solution 1 to 5 80 to 90 0 to 1
HNO3 solution 1 to 5 80 to 90 0 to 1
Steam - below 130 0 to 1

2. Features of ISC Inductive Conductivity Meter used in a CIP Process

zero-suppression function
Zero-suppression function
  1. Improved precision in boundary surface measurement.
    (a) Equipped with a zero-suppression function according to output signal
    * Zero suppression
    Example:
    Output: 4 to 20 mA DC
    Range: 100 to 300 mS/cm
    (b) One sensor can handle a minimum span of 100µS/cm and a maximum span of 1999 mS/cm.
  2. Steam sterilization capability
    Measurements can be performed at process solution temperatures of -10 to 130°C and pressures no greater than 2 MPa {20 kgf/cm2}

行业

相关产品&解决方案

FLXA202/21两线制变送器/分析仪

FLEXA系列分析仪用于工业设施中的连续在线测量。它是灵活的两线制分析仪,可选择单传感器或双传感器测量。

ISC40电感式(环形、无电极)电导率传感器

ISC40型传感器与EXA ISC分析仪组合使用。在可靠性、准确性、可调性和性价比方面,该组合满足甚至优于对电导率测量的期望。 

pH和ORP分析仪

pHORP流量计、分析仪和变送器用于pHORP的连续过程监测,以确保水/产品质量,如监测污水排放、批量中和、浆料存储、洗涤塔,冷却塔、化学品、水/废水处理和许多其他应用。

电导率传感器

电导率传感器和电极用于测量过程电导率、电阻率、WIFI、软化水、RO水、百分比浓度、锅炉水排污和TDS。有伸缩式、流通式、浸入式和直插式等多种安装选项。选择合适的电极/传感器对优化测量结果至关重要。

×

Have Questions?

Contact a Yokogawa Expert to learn how we can help you solve your challenges.

置顶
WeChat QR Code
横河电机(中国)有限公司
WeChat Recruiting QR Code
横河电机中国招聘