Refinery Wastewater: Oil & Grease Removal

下载 (694.1 KB)

Background Information

Removal of free oil and grease from a wastewater stream reduces the potential for equipment problems to occur further downstream. There are three forms of oil encountered in wastewater treatment at a refinery. They are:

  1. Free Oil or floating oil is removed by either skimming the surface in the skim tank or by gravity separation in the API separator.
  2. Emulsified Oil is comprised of oil droplets in stable suspension within the wastewater. Removal requires chemical addition to lower the pH followed by addition of dissolved oxygen or nitrogen to remove the emulsified oils as they break free from the wastewater.
  3. Dissolved Oil is a true molecular solution within the water and can only be removed with biological treatment.

Figure 1 shows a typical biological wastewater treatment schematic; however other treatment options do exist as well. Biological treatment systems are commonly used for "normal" industrial oily wastewater streams, and can also be used to treat sanitary waste. A disadvantage is the difficulty sustaining the biomass environment due to high swings in wastewater concentrations, TDS and temperature.

wastewater-system
Figure 1

 

Introduction


api-seperatorsAPI Separators: API or American Petroleum Institute Separators are normally the first and most important step in a refineries wastewater treatment. It uses the differences in oil and water's specific gravity to filter out the majority of free oil within the mixture. The lighter oils will remain at the top of the liquid and can be skimmed off, while the heavier oil will settle to the bottom.

The above figure shows a detail drawing of a typical API separator. A conventional oil-water separator contains a conveyor to assist in the separation of the heavier oils and grease, a scraper/skimmer and a baffle.

pH is typically measured at the outlet as an indicator of potential problems, such as flocculation, in the secondary treatment. It is important to note that because emulsified oil is still present in the water mixture, coating will occur causing a sluggish reading.

At this point in the treatment process the emulsified oil is still in soluble form. The removal of the emulsified oil requires either a chemical addition to lower the pH or use of emulsion breakers.

Dissolved/ Air Flotation: Once treated, the wastewater often enters an air flotation unit to remove the emulsified oil as it begins to break free from the wastewater, using dissolved oxygen or nitrogen.

Bioreactors (Activated sludge treatment): At this phase the wastewater still contains dissolved oil in a true molecular form. The only way to remove the remaining dissolved oil is thru biological treatment. This and the remaining steps are the same as those found in a normal wastewater treatment facility.

Many components in the process must be in balance in order to obtain complete synergy such as, biomass blends, air, return activated sludge (RAS), waste activated sludge (WAS) and throughput. It is essential to monitor and control all factors which influence the efficiency of the biological conditions in the basin; for example:

Temperature: Most biomass achieves optimum efficiency in a temperature range between 10-40°C. Increasing or decreasing the temperature can result in the increasing or decreasing the rate at which the bugs eat and reproduce. All chemical reactions taking place are affected by the process temperature as well.

pH: For most systems the pH should be kept between 6.5 to 8.5 pH, when the pH is too high or too low, the biomass loses the ability to convert the food to energy and raw materials. A pH below 6.5 may cause growth of fungi and fungal bulking, and will have to be adjusted using a caustic, lime or magnesium hydroxide.

Low Nutrients: If nitrogen and phosphorus are not present in sufficient amounts it can limit the growth rate of the biomass. A sign of nutrient deficiency includes foam on the aeration basin.

Dissolved Oxygen: DO is a critical measurement and will be maintained between 1-3 mg/L. The concentration is an indication of the basin environment; whether it is in denitrification (excess nitrate, NO3) or nitrification (excess ammonium, NH4) environment. Essentially the DO measurement is used to minimize ammonium breakthrough. It is not uncommon to see NH4 and DO measurements together.

Septicity/Toxicity: Septic wastes contain elevated amounts of sulfides and organic acids (such as acetic acid).Other organic materials and heavy metals are also toxic to the biomass, reducing their efficiency or even destroying them.

 

Summary

Maintaining proper pH measurements upstream and decrease problems seen downstream.

相关行业

  • 供排水

    水资源是有限的,因此促进可持续水循环是联合国可持续发展目标(SDGs)之一。横河电机一直致力于提供先进的数字化控制解决方案,以实现清洁安全用水的稳定供应、通过污水处理保护水环境、管理水资源流失,并优化工厂运行以减少二氧化碳排放和运营成本。凭借我们先进的技术、可靠的产品以及在全球各类水务项目中积累的丰富专业经验,我们与您携手提供可持续的水务解决方案,助力您的业务发展,并在工厂整个生命周期内创造价值。

    横河电机为市政用水和工业用水市场提供广泛的水控制应用支持。

相关产品&解决方案

  • FLXA402多通道四线制分析仪

    FLEXA™系列分析仪是模块化设计的分析仪,用于在工业设施中进行连续在线测量。可提供单传感器或多传感器测量。

     

  • Optical Dissolved Oxygen Sensors DO71/DO72

    It is a fluorescent dissolved oxygen sensor that is easy to clean and stable for long term measurement. Sensor replacement is easy on site and reduces maintenance costs. It is possible to measure oxygen in a wide range including low concentration measurement.
    Suitable for use in water treatment plants such as sewage treatment plants and wastewater treatment plants under severe measurement conditions.
    Can be used in combination with FLXA402 liquid analyzer by digital communication.

  • SENCOM™ SMART数字传感器

    数字或SMART传感器将特定的测量和标定数据保存在集成芯片上。集成芯片是传感器的重要组成部分。这些数据可以通过数据管理软件(如SPS24)在传感器和过程变送器或实验室PC之间进行交换。

  • 两线制变送器/分析仪FLXA21

    FLEXA™ 系列分析仪用于工业装置中的连续在线测量。可选配单传感器或双传感器测量,是现有非常灵活的两线制分析仪。

  • 测量传感器DO30G

    DO30G溶解氧传感器用于水处理厂,如污水处理厂、活性污泥废液处理和饮用水处理等。还适用于河水监测、水源保护、鱼类养殖及其他注重水质的领域。

  • 溶解氧传感器

    电极和传感器是溶解氧(DO)测量的传感部分。有三种常用的溶解氧测量技术:极谱法、电流法和光学法。以及各种安装选项,包括浮球、可伸缩、流经、浸入和直接插入。


置顶
WeChat QR Code
横河电机(中国)有限公司