Top Gas Density Measurement in a Fluid Catalytic Cracker (FCC)

Application Scope

Industry:        Refining
Product:         Gas Density Meter

Introduction

The top gas generated at the top of a distillation column in a petroleum refinery’s fluid catalytic cracker(FCC) is used to produce gasoline and LPG. As the composition of this gas varies depending on the running conditions of the cracker as well as the composition of the crude oil, its density (= molecular weight) must be constantly monitored and measured. The GD402 Gas Density Meter has been introduced for this explosion protected application. It features an intrinsically safe and explosionproof design, fast response, and a dust-proof, anti-corrosive, and flameproof construction.

Expected Benefits

  • Ensures stable and rapid measurement of gas density under hazardous conditions
  • Capable of displaying specific gravity and molecular weight readings derived from the density data
  • Greatly reduces the workload by ensuring continuous and accurate measurement 

Process Overview

In the petroleum refining system, an atmospheric distillation column or reduced-pressure distillation column is used to refine crude oil into gasoline, kerosene, and lubrication oil. In addition, the petroleum refining system incorporates an FCC to distill high-octane gasoline and LPG from the heavy contents of the crude oil. In many refineries the FCC unit serves as the primary unit, converting, or cracking low-value crude oil heavy ends into a variety of higher value, light products. The primary function of the FCC unit is to produce gasoline. Modern FCC units can process a wide variety of feedstock and can adjust operating conditions to maximize production of gasoline, middle distillate olefins (LCO) or light olefins to meet different market demands.

The top gas generated in the fraction column of the FCC goes through a heat exchanger and is then pumped to a high pressure. The resulting gas content is transferred to the LPG recovery system and the liquid content to the gasoline generation system. In this process, it is important to measure the density (specific gravity) of the gas because the data is essential as a critical parameter in controlling the operation of the FCC. In addition to being used to monitor the system and the quality of the product, this measurement can also help prevent pump pressure surges.

The GD402 Gas Density Meter has been introduced for this explosion protected application. It features an intrinsically safe and explosion-proof design, fast response, and a dust-proof, anti-corrosive, and flameproof construction. GD402 will ensure stable and rapid measurement of gas density under hazardous conditions. It is capable of displaying specific gravity and molecular weight readings derived from the density data, and it will greatly reduce the workload by ensuring continuous and accurate measurement.

Structure of FCC

 

Solution Details

Measurement System

Gas Density Meter (explosionproof type) :  GD40/...
Converter : GD402--E-E/...
Sampling system : Customized
Cubicles for detector and converter : Customized

Utilities

Power supply :
  Rated voltage, frequency ;  100 to 240 V AC, 50/60 Hz
  Operating voltage, frequency ;  85 to 264 V AC, 47 to 63 Hz

Power consumption: 12 W (max.)
  Steam ; 120 to 180°C (300 to 700 kPa)
                  Saturated steam (15 to 20 kg/h)

 Field Data

Process conditions

  Measurement point : Outlet of the top fraction column in the FCC
  Temperature : 34°C
  Pressure : 75 kPa to 185 kPa        
  Humidity : Wet        
  Gas composition : O2, N2, CO, H2, H2S, C1 to C5
  Dust : None

Measurement Range

  1,600 to 1,800 kg/Nm3

 

Flow Diagram of Sampling System

Notes

  • The cubicles for the detector and converter are separated to prevent the gas in the sampling section from cooling and liquefying while the converter is operating.
  • The capillary tubes for introducing the gas that is to be measured and the inside of the cubicles are heated with steam so that the heavy contents (C5 or more) will not liquefy.

 

Industrias Relacionadas

  • Transporte, distribución y comercialización de petróleo y gas

    La industria de la refinación, comercialización y distribución de petróleo y gas ha estado enfrentando un número cada vez mayor de retos en años recientes. Entre ellos, las características cambiantes de la materia prima a procesar, el envejecimiento de las instalaciones y los equipos de procesos, el creciente costo de la energía, la falta de operadores de planta capacitados que puedan operar una refinería de manera segura y eficiente y los requisitos constantemente cambiantes del mercado y de los clientes.

    Con el paso de los años, Yokogawa ha formado alianzas con muchas compañías de refinación, comercialización y distribución para proveer soluciones industriales enfocadas en resolver estos retos y problemas. Las soluciones VigilantPlant de Yokogawa han ayudado a los propietarios de plantas a alcanzar una máxima rentabilidad y seguridad sostenible dentro de sus plantas.

  • Refinación

    En el siempre cambiante mercado, las refinerías no solo son vistas como unidades de procesamiento de crudo, sino también como centros de beneficios. Al mismo tiempo, hay una clara conciencia de la necesidad de la seguridad en este tipo de instalaciones. Una solución de la producción total que abarca la planificación, programación, administración y control es necesaria para lograr los objetivos a largo plazo para la rentabilidad, la eficiencia y la protección del medio ambiente. Con años de experiencia en el campo de la automatización, Yokogawa puede traer soluciones totales accesibles para mejorar la operatividad y un mundo más limpio.

Productos y Soluciones Relacionadas

  • GD40 Detector

    The GD40 detector is designed for intrinsically safe and flameproof, explosion protected applications. It is designed to be virtually maintenance free for all accepted applications.

  • GD402/GD40 Gas Density Analyzer

    The GD402 gas density analyzer and GD40 gas density detector provide continuous measurement of gas density as well as other valuable parameters, including specific gravity and percent concentration.

×

 

 