I used the parameter conversion tool to convert GREEN series data for the UTA series. I can’t add the CC-Link communication option code to the converted data.

You can use the conversion tool. You don’t have to do anything after you create it.
The steps are as follows:

  1. Perform the Green conversion using the conversion tool.
  2. Write the converted file to the UTA (with the CC-Link option) main unit.
  3. Do an “upload all” from the main unit.
  4. Manually configure only the CC-Link parameters.
  5. Use file compare to confirm the differences.

 

Productos y Soluciones Relacionadas

  • UP550

    1/4 DIN sized sophisticated Program Controller features 5 powerful control modes and 30 program patterns. It comes with large PV display and LCD display for interactive setting and programming. The universal I/O, "SUPER" and "SUPER2" are also featured. Position proportional, heating/cooling model and RS-485 communication option are also available.

  • UP750

    1/4 DIN sized large-capacity Program Controller features Custom Computation, 300 program patterns, and 11 powerful control modes including dual-loop control. It comes with easy-to-see large PV display and LCD display for interactive setting and programming. The universal I/O, "SUPER" and "SUPER2" are also featured. Two ports of RS-485 communication are option.