pH in Acetic Acid

Introduction: 

Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid.

Between 30 and 70% (w/w) acetic acid contents, extractive distillation was suggested. Extractive distillation is a multicomponent-rectification method similar in purpose to azeotropic distillation. In extractive distillation, to a binary mixture which is difficult or impossible to separate by ordinary means, a third component termed an entrainer is added which alters the relative volatility of the original constituents, thus permitting the separation. In our department acetic acid is used as a solvent during the obtaining of cobalt(III) acetate from cobalt(II) acetate by an electrochemical method.

After the operation, the remaining waste contains acetic acid. In this work, acetic acid which has been found in this waste was recovered by extractive distillation. Adiponitrile and sulfolane were used as high boiling solvents and the effects of solvent feed rate/solution feed rate ratio and type were investigated. According to the experimental results, it was seem that the recovery of acetic acid from waste streams is possible by extractive distillation.


There are many methods available for the separation of acetic acid like, solvent extraction, distillation, adsorption, pervaporation and ion exchange.

Why pH is important?

If we take one of the separation technique as an example say using liquid membrane for separation. The vegetable oil being  hydrophobic in nature allows the selective transport of acetic acid through it from the feed phase to the strip phase. Acetic acid is transported across the membrane from the feed phase in its unionized molecular form and not in its ionic form that is acetate. This required that the pH of the feed phase is lower than the pKa value of acetic acid which is 4.76 (at 25 degC). At pH above 4.76 acetate ion is formed, which cannot be permeate through the liquid membrane.

The pH value of the feed phases of 0.1 M, 0.05 M and 0.01 M concentrations of acetic acid was found to be 3.23, 3.65 and 4.05 respectively. These pH values are lower than the pKa value of acetic acid, enabling permeation of acetic acid across the membrane.

Critical area: Pure acetic acid service, which will have low conductivity. Acetic acid (systematically named ethanoic acid is an organic compound with the chemical formula CH3COOH (also written as CH3CO2H or C2H4O2). It is a colorless liquid that when undiluted is also called glacial acetic acid. Acetic acid has a distinctive sour taste and pungent smell. Although it is classified as a weak acid, concentrated acetic acid is corrosive. Acetic acid is the second simplest carboxylic acid (the simplest is formic acid) and is an important chemical reagent and industrial chemical.

Typical process details:

Pure acetic acid service, more than 30%

Water even less than  <1%.

Typical problems:

The acid has very low conductivity so measurement is difficult.

Remedies:

To use a flowing special sensor to get a good electrolytical contact between reference cell and process.

Product Recommendations

Measurement System

Process Liquid Analyzer: 

  • 2-wire FLEXA pH/ORP Analyzer
 
 
2-wire FLEXA pH/ORP Analyzer
 
Features

Dual sensor measurement on 2-wire type analyser

Redundant system on dual sensor measurement

Easy touch screen operation on 2-wire type analyzer

 
 
  • 4-wire FLXA402 pH/ORP Analyzer

4-wire PH450G pH/ORP Analyzer

Features

Connectable to upto five sensor

Easily viawable color LCD

Touch screen operation

 

Sensor Selection:

Yokogawa sensor SC21C-AGC55 can be the solution.

SC21C-AGC55

This flowing electrolyte sensors uses a ceramic reference junction, with the electrolyte (3.3 molal KCl). The flow of electrolyte through the junction, while small, remains the safest way to prevent clogging and to protect the internal reference against poisoning and diffusion.

Features for type SC21C-AGC55

  • For tough application where pollution of the reference system is to be expected
  • Low ionic application where the positive flow of electrolyte provides the conductivity needed to measure pH(< 50 µS/cm)
  • Heavy duty pH sensitive glass.
  • Flowing reference system for pollution resistance, and highly stable reference potential.
  • Use in combination with the presurisable electrolyte reservoir to obtain a positive flow towards the process (K1500YA)

Temperature Sensor

SM60-T1 SERIES - For accurate pH measurement temperature compensation is required. Either a Pt100 or a Pt 1000 temperature electrode can be selected.

Cables used:

WU20-LT** Qty1 + WU20-PC** Qty1

Flow fitting:

F*20 various type of flow fittings can be used

Flow fitting

Tangible benefit

Save down time in cleaning, repeated calibration, improve end product quality.

 

Note: For additional information on this application contact the local Yokogawa Process Liquid Analyzer Department

업종

  • 석유화학

    석유화학 업종 고객사의 요구는 매우 다양합니다. 경쟁이 치열한 오늘날의 시장에서 앞서 나간다면, 생산자는 품질과 생산성을 향상시키기 위해 노력하고 있습니다. Yokogawa는 이 분야에서의 오랜 기간의 광범위한 경험을 바탕으로 이러한 요구에 맞는 맞춤 솔루션을 제공합니다.

    See More

Related Products & Solutions

  • 2-Wire Transmitter/Analyzer FLXA202

    The FLEXA™ series analyzers are used for continuous on-line measurements in industrial installations. With an option for single or dual sensor measurement, they are the most flexible two-wire analyzer available.

    See More
  • Digital SMART SENCOM™ Adapter, SA11

    Reusable SMART adapter, requiring only the analog sensor to be disposed of when it reaches the end of its lifetime. With the SENCOM 4.0 platform, Yokogawa delivers reduced costs and waste while contributing to its long-term business goals of a sustainable future for all.

    See More
  • Flow/NPT Fittings FF20/FS20

    Yokogawa는 설치 및 유지보수 시간을 줄이고 결과적으로 운영 비용을 절감하는 설계에 특히 중점을 두어 전체 범위의 피팅을 생산하는데 상당한 설계 및 개발 시간을 투자했습니다.

    See More
  • Industrial pH/ORP Electrodes

    pH 측정 루프의 핵심은 전극 시스템입니다. Yokogawa는 이 핵심이 가장 가혹한 조건에서도 발휘될 수 있도록 광범위한 전극을 설계했습니다.

    See More
  • pH and ORP Analyzers

    pH와 ORP 미터, 분석계 및 전송기는 수질/제품 품질을 보장하고 유출물 배출량, 배치 중화, 펄프 스톡, 세정기, 냉각 타워, 화학, 폐수 처리 및 기타 여러 어플리케이션의 연속 공정 모니터링에 사용합니다.

    See More
  • pH and ORP Sensors

    pH 전극 및 센서는 pH 측정의 감지 부분입니다. Retractable, flow-though, 침적 및 직접 삽입을 포함한 다양한 설치 옵션이 있습니다.

    적절한 pH 전극 / 센서 선택은 최적의 측정 결과를 위해 중요합니다.

    See More

Top