Dissolved Oxygen Measurement in Continuous Aeration Sewage Treatment

Introduction

When used to measure the dissolved oxygen in an aeration tank, sensors tend to quickly become contaminated and need frequent cleaning. A cost-effective solution to this problem has finally been found with the development of the Yokogawa FLXA402 Dissolved Oxygen Converter system. With this system, the sensor is mounted in a float ball holder that protects it from contamination and enables continuous maintenance-free use for extended periods.

 

Expected Benefits

  • Continuously and stably measures dissolved oxygen concentration
  • Reduces operating costs
  • Eliminates the need for manual cleaning

 

Process Overview

Sewage that flows into a treatment plant is sent to a primary sedimentation tank to remove the garbage and sludge. Thereafter, it is routed to an aeration tank where activated sludge (sludge containing bacteria, protozoa, and other microorganisms) is added and air is blown into the mixture to agitate it.
The microorganisms in the activated sludge thrive on the oxygen and cause the organic substances in the sludge to proliferate and the generated solids to be precipitated.
A shortage of dissolved oxygen (DO) will kill the microorganisms, so the DO concentration in the aeration tank must be properly controlled. A DO analyzer is used to continuously measure the DO concentration.

Sewerage treatment procedure
Sewerage treatment procedure

The spherical float stays relatively clean because contaminants are washed off by the surface-level flow of water. The sensor diaphragm is kept relatively free of contamination as it is positioned at the same height as the top portion of the float.

PB350G/DO30G""

 

Solution Details

Measurement System

  • Detector: DO30G-NN-50-□□/PN
  • Float holders:
    Angled type: PB350G-PV-25-NN
    Vertical type: PB360G-PV-□5-NN
  • Converter: FLXA402-A-B-□□-D1-NN-A2-WR
  • Terminal box (as needed): WTB10-DO3-NN- □□/□
    With the WTB10 terminal box, the sensors and the converter can be up to 50 meters apart.

Utilities

  • Power supply:
    100 V AC ±15 %, 50/60 Hz
    115 VAC ± 15 %, 50/60 Hz
    230 VAC ± 15 %, 50/60 Hz
  • Power consumption: max. 10 VA

Precautions

  • The measuring point must be at a location where air bubbles are not a frequent occurrence.
  • To prevent the sensor diaphragm from being damaged by solids in the sample liquid, the arm of an angled float holder should be pointed in the downstream direction.

 

Field Data

No effects of contamination after four months of continuous operation

We conducted a test with two DO30G sensors that were equipped with the PB350G Float Ball Holder. During the test, no maintenance was performed on one of the DO30G sensors, while the other DO30G sensor was cleaned every two weeks and calibrated monthly. Over the entire duration of the test, the DO30G sensor that did not receive cleaning showed minimal contamination. Furthermore, its measurements did not deviate appreciably from those of the sensor that was regularly maintained.

DO readings after four months of continuous operation

Related Industries

  • Water & Wastewater

    수자원은 한정되어 있으므로 지속 가능한 물 순환에 기여하는 것은 지속가능개발목표(SDGs) 중 하나입니다. Yokogawa는 깨끗하고 안전한 물의 안정적인 공급, 수질 환경 보호를 위한 폐수 처리, CO2 배출량 및 운영 비용 절감을 위한 물 손실 관리 및 플랜트 운영 최적화를 위한 첨단 디지털 제어 솔루션을 제공해 왔습니다. 최첨단 기술, 신뢰할 수 있는 제품, 그리고 전 세계 다양한 수자원 프로젝트에 대한 풍부한 전문 지식과 경험을 바탕으로, Yokogawa는 고객과 협력하여 플랜트 수명 주기 전반에 걸쳐 비즈니스를 성장시키고 가치를 창출하는 지속 가능한 수자원 솔루션을 제공합니다.

    Yokogawa는 지자체 및 공업용수 처리 시장에서 광범위한 수처리 응용 분야를 지원합니다.

      

     

  • 폐수처리

    폐수 처리 설비는 많은 모터, 펌프, 송풍기 등을 사용하기 때문에 운전 비용을 줄이기 위해서는 전력 소비를 줄이는 것이 중요합니다. Yokogawa는 에너지 효율성을 높이기 위한 최적의 제어 솔루션을 제공합니다. 

  • 수처리

    Yokogawa는 수처리 설비의 더욱 안정적인 운영을 위한 최적의 솔루션을 제공합니다. 이러한 솔루션에는 정교한 기술, 탁월한 제품 품질 및 라이프 사이클 전반에 걸친 광범위한 애플리케이션 노하우가 포함됩니다.

Related Products & Solutions

  • Dissolved Oxygen Sensors

    용존 산소 (DO) 전극과 센서는 DO 측정의 감지 부분입니다.

    용존 산소 측정에는 세 가지 일반적인 기술이 있습니다. : 폴라로그래픽, 갈바닉 및 옵티칼 

    Floating ball, Retractable, Flow-though, 침적 및 직접 삽입을 포함한 다양한 설치 옵션이 있습니다.

  • Liquid Analyzers

    액체 분석계는 수질을 포함한 화학 공정을 모니터링하고 공정의 최적화 및 제어 기능을 제공합니다.

  • Measuring Sensor DO30G

    용존산소용 DO30G 센서는 하수처리장, 유출활성 슬러지 공정 및 음용수 처리와 같은 수처리 설비에서 사용하도록 설계되었습니다. 또한 하천 감시, 섭취 보호, 양식장 및 수질이 중요한 분야에도 효과적입니다. 

  • Optical Dissolved Oxygen Sensor DO70G

    광학 용존 산소센서 DO70G는 하수 처리 시설 및 유출활성 슬러지 공정과 같은 수처리 설비에서 사용하도록 설계되었습니다. 


Top