pH in Ammonia Scrubbing

다운로드 (152 KB)

Introduction 

A process and apparatus for removing SO2 from a gas stream having the steps of scrubbing the SO2 with an ammonia scrubbing solution and removing any aerosols generated by the scrubbing in a wet electrostatic precipitator. The scrubbing solution is maintained at a pH between 6 and 8 to increase the speed of absorption of SO2, to Increase the ratio of sulfite to bisulfite which also facilitates the oxidation of SO2, and to avoid the need to use exotic, corrosion resistant alloys. Ammonium sulfate, a valuable fertilizer, can be withdrawn from the scrubbing solution.

Scrubbing as a Function of pH in a 10% Ammonium Sulfate Solution

Process background 

Fossil fuels are burned in many industrial processes. Electric power producers, for example, burn large quantities of coal, oil, and natural gas. Sulfur dioxide (“SO2”) is one of the unwanted byproducts of burning any type of fossil fuel. It is known to cause acid rain, and to have serious negative health effects on people, animals, and plants. A great deal of research has been done to find a way to economically remove SO2 from flue gas streams before it enters the atmosphere.

The pH of the ammonium sulfate solution should be kept between about four and six. This range is the result of a compromise between competing factors. On one hand, ammonium sulfate solution is capable of absorbing SO2 more rapidly when its pH is higher. The ability to absorb SO2 better implies that the size of the scrubbing tower can be smaller, thus saving capital costs. In addition, the liquid to gas (“L/G”) ratio can be smaller, meaning less liquid will be required and operating costs will be lower.

On the other hand, higher pH levels are also associated with the release of free ammonia from solution, often termed “ammonia slip.” In addition to incurring an economic loss because of lost ammonia, free ammonia in the scrubbed flue gas reacts with uncaptured sulfur dioxide and trioxide to create an ammonium sulfate/bisulfite aerosol that is visible as a blue or white plume in the stack discharge, leading to secondary pollution problems. Controlling the amount of free ammonia in the desulfurization process is in part a function of the ammonia vapor pressure, which results from a combination of pH and levels of unoxidized ammonium sulfite that remain in the absence of sufficient oxygen. Therefore, high pH values and high levels of unoxidized ammonium sulfite promote ammonia slip.

Typical Process Example 

  • Name of Application / Process: Ammonia Scrubbing
  • Location of Sensor mounting (location name): Tail Gas Scrubber Complex
  • Operating Temp / Max.Temp: 75 to 80 deg C
  • Operating Press / Max. Press: 2 to 2.5 Kg/cm2
  • Type of Installation: On Pipe ( Direct mounting ) / Flow through Chamber (By pass mounting ) /
  • Process Composition: Liquid - Scrub Acid,
    • P2O5:105 ppm,
    • AN (Ammonical Nitrogen):1326 ppm,
    • UN(Urea Nitrogen):22 ppm,
    • TN(Total Nitrogen):1348 ppm,
    • Florine:116 ppm.

Typical problems

  • Frequent cleaning, glass can be eaten away as the temperature and chemical attack glass

Remedies

  • Use of high temperature special sensor

Product Recommendation

Measurement System

Process Liquid Analyzer: 

  • 2-wire FLEXA pH/ORP Analyzer

2-wire FLEXA pH/ORP Analyzer

 

Features

  • Dual sensor measurement on 2-wire type analyser
  • Indication of sensor wellness

 

  • 4-wire PH450G pH/ORP Analyzer

4-wire PH450G pH/ORP Analyzer

Features

  • Easy touchscreen operation
  • Trending display up to 2 weeks
  • Advanced Process Temperature Compensation

Sensor Selection:

SC25 sensor from Yokogawa is the perfect sensor for this application. High temperature sensor SC25 because of its design can serve purpose.

SC25 sensors

 

 

Features SC25V

  • External titanium Liquid Earth
  • Pt1000 integration in pH compartment giving highly accurate temperature compensation
  • CIP and Steam cleaning possible
  • Large internal KCl volume giving the sensor a longer life time
  • SC25V-ALP25 for chemically harsh applications and high temperatures

Cable:

  • WU10-V-S series

Retractable fitting:

  • PR10 series

On-line measurements always present extra challenges compared to at-line measurements, for example, when maintenance needs to be done. Applications like this where the sensors have to be removed without interruptions or shut-downs the PR10 is especially suitable. Without any special tools the PR10 can be retracted safely from the process up to 5 bar.

For ease of use optional flush ports are available. In the retracted position the sensor can be kept moist, cleaned or even calibrated. This can all be done without process interruption or disassembly of the armature.

PR10 series

Tangible benefit

Better life of sensor, improve end product quality.

Note: For additional information on this application contact the local Yokogawa Process Liquid Analyzer Department

 

 

Related Products & Solutions

12mm Digital SMART pH Sensor SC25F

SC25F는 일체형 온도 소자와 액체 접지 전극을 포함하는 12mm 디자인의 디지탈 SMART pH 센서 입니다.

12mm pH Sensor SC25V

The SC25V는 12 mm 디자인의 pH 센서로 내장형 온도 소자와 액체 접지 전극을 포함합니다.

2-Wire Transmitter/Analyzer FLXA202/21

FLEXA ™ 시리즈 분석기는 산업용 설비의 연속 온라인 측정에 사용됩니다. 단일 또는 이중 센서 측정 옵션이 있어 가장 유연한 2 선식 분석기입니다.

4-Wire pH/ORP Analyzer PH450

PH450 pH와 ORP 분석계인 PH450은 pH와 온도, ORP(Redox) 측정을 결합한 다변형 분석계로, mA 전류 출력 2개, 독립적인 SPDT 접점 출력 및 HART 등 다양한 출력기능을 통해 활용할 수 있습니다. 

pH and ORP Analyzers

pH와 ORP 미터, 분석계 및 전송기는 수질/제품 품질을 보장하고 유출물 배출량, 배치 중화, 펄프 스톡, 세정기, 냉각 타워, 화학, 폐수 처리 및 기타 여러 어플리케이션의 연속 공정 모니터링에 사용합니다.

×

Have Questions?

Contact a Yokogawa Expert to learn how we can help you solve your challenges.

Top