The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. A ladder sequence function is included as standard. The short depth of the controller helps save instrument panel space. The UT35A/UT32A also support open networks such as Ethernet communication.
UT35A and UT32A Temperature Controller Features
The control mode allows easily configuring settings and making changes with parameters.
For the correspondence between the above control mode and control types for each model, please refer to the specifications of each model.
With built-in ladder sequence control, the range of applications are dramatically increased. This feature is standard in all the UTAdvanced controllers (except UM33A). The ladder sequence control function can replace a small PLC required by the application. Sequence control and PID control can be performed simultaneously.
[Example of ladder instruction] | [Example of ladder programming] |
![]() |
Alarm Sequence Control Circuits Can be Reduced
The ladder sequence program is built in the UTAdvanced as standard. The ladder sequence function enables monitoring and controlling peripheral devices such as relays, thus making it possible to reduce costs.
[Conventional] |
![]() |
[UTAdvanced] Alarm action is built by the ladder sequence program inside the UTAdvanced, thus making it possible to reduce costs. |
Host System Load is Reduced
[Conventional] |
[UTAdvanced]![]() The UTAdvanced with up to 4 analog inputs* enables various types of analog data to be captured directly into the controller and calculated by the ladder program, thus reducing the system-building load of the host. Action: Various types of analog data were captured into the host system (PLC, etc.) and calculated, and the results were processed by the field controller for control via a command. * In the case of the UT55A |
Universal Input
Select from TC, RTD, mV/DC voltage and DC current. (DC current input: No shunt resistor required)
The input type and range is user selectable via the front panel or by using the LL50A parameter setting software.
All instruments have a 15 V Loop Power Supply (15 V LPS) for a transmitter.
In addition, a 24 V LPS is also available simultaneously for some instruments as optional function.
User selectable for relay, Voltage pulse and current outputs.
Heating/cooling control has two sets of universal outputs.
Drive a motorized control valve by using position-proportional PID.
The following conditions can be set in order to increase the accuracy of calculating PID constants using AT .
The field proven SUPER function utilizes a built-in operator experience and fuzzy theory to deliver fine control and suppress overshoot.
The new SUPER2 function utilizes a built-in operator experience and modern control theory to deliver fine control and suppress hunting.
Parameters that determine controller functions can easily be set: controller model type, controller mode (single-loop control, cascade control, loop control with PV switching, etc.), universal input/output functions, setup parameters and others. It also allows you to create program patterns.
Used to tune a controller's PID parameters. Displays measured input value, target setpoint, and control output value as a trend graph on a personal computer screen, allowing PID parameter modification, AUTO/MAN switching, control output modification in manual operation, etc.
Ladder sequence programs can be created and ladder programs can be monitored.
Can be used to create an electronic device data sheet for Open Network.
Can be set parameters and ladder program while no power supply to controller.
Can be used while attached to the control panel.
SP Display | Program Pattern Display | Remaining Segment-time Display | Remaining Repetition Display |
![]() |
![]() overview |
![]() |
![]() |
TSP Display | Program Pattern Display | Segment Number Display | |
![]() |
![]() Soak and ramp |
![]() |
|
Event Display | |||
![]() |
* The same operation displays as those of the UT are also available.
Functions of the Program Controller
Fast-forwarding of program operation
Use this function when checking the program pattern setting. Only times of segments and time events can be faster.
Program pattern-2 retransmission
The controller can serve as a program pattern generator.
Synchronized program operation
If the progress of the operation of one unit is faster, the program operation can be forcibly stopped by digital input when switching between segments. Thus, synchronized program operation can be performed.
The controller menus and layout are adjusted in accordance with the level (EASY, STD, PRO) of information required by the user. If simple temperature or level control is needed, then select the easy configuration. Very sophisticated applications are no problem for the UTAdvanced. Just select the PRO setting and make use of the additional functionality shown in this mode. Advanced applications can be programmed in the PRO setting and then changed back to the easy setting to lock out functions not required by operators.
With Yokogawa's Active color display you can instantly tell, at a glance, the status of your process.
Alarm Status: Active color display changes from white (normal) to red (alarm).
Deviation Status: Color changes based on a PV deviation from SP.
User-defined Color: Choose between white or red display for constant Readings.
The 65-mm depth of the controller reduces the constraints on installation location.
The navigation keys is an intuitive method to navigate the controller's configuration menus and setting its various menus. Navigation arrows even tell you what button to push next.
It is easy to assign frequently used functions, such as the operation mode switch, Run/Stop, program pattern selection, Remote/Local, alarm latch release, and PID parameter display. The function of an external switch can also be assigned to the front panel key in conjunction with a ladder sequence program.
The UTAdvanced is equipped with a scrolling text feature that fully lists the parameter being modified. There is no guessing what parameter you are looking at. It is possible to turn off scrolling the text function.
The UTAdvanced is fluent in multiple languages — English, Spanish, French, and German. The use of the UTAdvanced by local language operators is not an obstacle.
Parameter values (SP, P, I, D, ALM1, etc.) configured by the user can be stored in the controller as the default values. Even if a parameter set value is accidentally changed, it can be restored to the original value with a simple operation.
Now you can choose a color that matches your work area: white (light gray), or black (light charcoal gray).
LL50A Parameter Setting Software (sold separately) allows for easily setting parameters.
Using the message function and turning the contact input on/off, the message registered beforehand can be displayed on PV display by interrupt.The message is registered using LL50A Parameter Setting Software.The messages are limited to 20 alphanumeric characters. A maximum of four messages can be registered.
Quick Setting Function
Minimum parameters necessary for operation can be set.
Security Function
The password function can prevent inadvertent changes to the parameter settings. If a password is set, the password is required when moving to the Setup Parameter Setting Display. When the password is verified, can be changed to the Setup Parameter Setting Display.
A simple and easy network connection is provided!
A built-in function in the controller eliminates the need for a converter and makes wiring simple.
Modbus TCP/IP, a protocol that allows the controller to connect to any Ethernet network and have the ability to exchange data with the computers or devices on that network.
The data of UTAdvanced (slave units) can be displayed and saved on the DXAdvanced using the Modbus RTU function.
Embedded open networks will provide direct connection to PLC's.
RS485 communication. Up to 31 connected slaves with a maximum length of 0.7 miles.
The use of the ladder sequence program makes it possible to exchange analog data and status data between communication-capable UTAdvanced.
Example: A UTAdvanced in which an input error occurs sends a signal to another UTAdvanced to enable that UTAdvanced switch to MAN operation, thus shifting the whole system into a safe mode. In such a case, the safety mechanism can be built into the UTAdvanced and is not required in the host system.
In coordinated operation, a single UTAdvanced termperature controller is used as a master controller and multiple UTAdvanced or other UTAdvanced digital indicating controllers as slave controllers.
The slave controllers are operated in accordance with the actions of the master controller.
A protocol used for communicating with a general-purpose personal computer, or UTAdvanced series link module and serial communication module of FA-M3R (range-free controller).
Backed by the high reliability and quality that Yokogawa has cultivated over many years.
UTAdvanced is environmentally safe when disposing.
UTAdvanced can also be used for food-processing equipment with washable control panels.
ITEM | UT35A | UT32A | |
---|---|---|---|
PV input | Input type | 1 Universal input (TC, RTD, mV, V, mA) | |
Indication accuracy | ±0.1% of F.S. | ||
Control scan period | 200 msec | ||
PV/SP data display | 14-segment, 5 digits, Bar graph LCD display | ||
Control outputs (MV) | Type | Relay, Voltage Pulse, Current | |
Algorithm | ON/OFF, PID (Continuous, Time-proportional), Heating/Cooling, Position-proportional | ||
Digital inputs | Number | 2 (Std) 7 (Max) | 2 (Std) 4 (Max) |
Type | SP No.Change, PID No. Change, A/M Change, etc | ||
Digital outputs | Number | 3 (Std) 8 (Max) | 3 (Std) 5 (Max) |
Function | PV High, PV Low, Dev High, etc | ||
Current trans input (option) | Number | 2 | |
Retransmission | Number | 1 | |
Type | PV, SP, OUT, etc | ||
Remote (aux.) input (option) | Number | - | - |
Type | - | ||
Loop power supply (LPS) (option) | Number | 1 | |
Voltage | 21.6 to 28.0 VDC | ||
Communication (option) | Number | 1 | 1 |
Type | RS-485, Ethernet, PROFIBUS-DP, CC-Link, DeviceNet | RS-485 | |
Other specifications | Power supply | 100 to 240 VAC (+10%, -15%) or 24 VAC/DC (+10%, -15%) (option) | |
Power consumption | Max 18 VA | Max 15 VA | |
Mass | Max 0.5 kg |
![]() |
![]() |
![]() |
![]() |
![]() |
|||
Model | UT75A | UT55A | UT52A | UT35A | UT32A | ||
---|---|---|---|---|---|---|---|
Size | 1/4 DIN | ✓ | ✓ | ✓ | |||
1/8 DIN | ✓ | ✓ | |||||
Depth from the panel surface (mm) | 65 | 65 | 65 | 65 | 65 | ||
Number of Control loops | Standard (Maximum) | 1(2) | 1 | 1 | 1 | 1 | |
Control Scan Period | (msec) | Choice 50/100/200 | Choice 50/100/200 | Choice 50/100/200 | 200 | 200 | |
Display Function | Number of PV Display Digits | 5 | 5 | 5 | 5 | 5 | |
Active Color PV Display Function | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Guide Scroll Display Function | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Message Display Function | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Bar graph display (Number) | ✓(2) | ✓(2) | ✓(2) | ✓(1) | ✓(1) | ||
PV Input Indication Accuracy | (% of F.S.) | 0.1 | 0.1 | 0.1 | 0.1 | 0.1 | |
PV Input Type | TC | ✓ | ✓ | ✓ | ✓ | ✓ | |
RTD (3-wire) | ✓ | ✓ | ✓ | ✓ | ✓ | ||
RTD (4-wire) | ✓ | ✓ | ✓ | ||||
mV, V | ✓ | ✓ | ✓ | ✓ | ✓ | ||
mA | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Number of Analog Inputs | Standard (Maximum) | 1(4) | 1(4) | 1(2) | 1 | 1 | |
Number of SPs (PIDs) | Maximum | 20(16) | 8 | 8 | 4 | 4 | |
Number of Control Modes | Maximum | 9 | 8 | 8 | 1 | 1 | |
Number of Control Types | Maximum | 8 | 8 | 8 | 5 | 5 | |
Control Output | Type | Relay Contact Output, Voltage pulse output, Current output | ✓ | ✓ | ✓ | ✓ | ✓ |
Algorithm | ON/OFF | ✓ | ✓ | ✓ | ✓ | ✓ | |
PID (Continuance, Time Proportion) | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Position proportional | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Heating/cooling | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Number of Analog Outputs | Standard (Maximum) | 2(3) | 2(3) | 2(3) | 2 | 2 | |
Number of Digital Inputs | Standard (Maximum) | 3(8) | 3(9) | 3(5) | 2(7) | 2(4) | |
Number of Alarms | 8 | 8 | 8 | 4 | 4 | ||
Number of Digital Outputs | Standard (Maximum) | 3(8) | 3(18) | 3(5) | 3(8) | 3(5) | |
Communication | RS-485 communication (Maximum) | ✓(2) | ✓(2) | ✓(1) | ✓(1) | ✓(1) | |
Ethernet communication | ✓ | ✓ | ✓ | ||||
Open Network (CC-Link/PROFIBUS-DP/DeviceNet) | ✓ | ✓ | ✓ | ||||
920 MHz band wireless communication |
✓ |
✓ |
|||||
Various Function | Quick Setting Function | ✓ | ✓ | ✓ | ✓ | ✓ | |
Split Computation Output Function | ✓ | ✓ | ✓ | ||||
Ratio and Square Root Extraction Function | ✓ | ✓ | ✓ | ||||
Remote SP Function | ✓ | ✓ | ✓ | ||||
24 V DC Loop Power Supply Function | ✓ | ✓ | ✓ | ✓ | |||
Heater Break Alarm Function | ✓ (Standard type) |
✓ (Standard type) |
✓ (Standard type or Heating/ cooling type) |
✓ (Standard type or Heating/ cooling type) |
|||
Ladder Sequence Function | (Number of max. steps) | ✓(1000) | ✓(500) | ✓(500) | ✓(300) | ✓(300) | |
Other specifications | Power Supply | AC100 V to 240 V | ✓ | ✓ | ✓ | ✓ | ✓ |
AC/DC 24 V | ✓ | ✓ | ✓ | ✓ | ✓ | ||
Dust and waterproof Level of Front Panel | NEMA4 *1 (IP66) | NEMA4 *1 (IP66) | NEMA4 *1 (IP66) | NEMA4 *1 (IP66) | NEMA4 *1 (IP66) | ||
Configuration Tool | Via Light-loader Communication | ✓ | ✓ | ✓ | ✓ | ✓ | |
Via Maintenance Port Communication |
✓ | ✓ | ✓ | ✓ | ✓ | ||
Via RS-485/Ethernet communication |
✓/✓ | ✓/✓ | ✓/- | ✓/✓ | ✓/- |
The table above includes specifications of the standard models only.
* 1: Hose down test only.
Input Range
Input type | |
---|---|
TC | K, J, T, B, S, R, N, E, L, U, W PL-2, PR20-40, W97Re3-W75Re25 |
RTD | JPt100, Pt100 |
DC Voltage | 0.4 to 2.0 V, 1.0 to 5.0 V, 0.0 to 2.0 V, 0 to 10 V, -10 to 20 mV, 0 to 100 mV |
DC Current | 4 to 20 mA, 0 to 20 mA |
UTAdvanced series Parameter map list for each model can be downloaded.
Please use it to manage and save the set parameters. Also please use it as a reference for the key operation at that time.
This is a list of recorder and controller products that support the RoHS (2011/65/EU) directive.
This is a list of recorder and controller products that support the New Legislative Framework (NLF.)
The UTAdvanced Digital Indicating Controller comes standard with ladder sequence function. The ladder sequence function can handle measured and computed values from the controller. Using this function, the UTAdvanced converts outputs from other controllers such as YS1500 to time proportioning outputs.
The TC series of temperature controllers is perfect for controlling the heating temperature of sealing parts and the temperature of sealing rolls (pre-heating) in a variety of different wrapping machinery.
Load devices are sometimes used when evaluating (measuring) DUT performance. Depending on the parameter being evaluated, multiple controllers can be employed to control the performance of the load device, but there are also times when the load device uses only one actuator.
In the plants of food and beverage manufacturers, there are times when monitoring and recording of production equipment is necessary inside clean rooms. This is an introduction to monitoring and recording in clean rooms using paperless recorders.