Spheroid Analysis

다운로드 (584 KB)

Introduction

The structures and functions of cells produced through spheroid formation are known to be more similar to live bodies than monolayer 2D organisms. Therefore, various formation methods and data accumulation for spheroids is progressing. We imaged spheroids using CellVoyager CV7000, and analyzed the images. Specifically, multiple images were captured along the Z-axis, reorganized into 2D image data*, and evaluated with regard to the maximum spheroid diameter and number of contained cells. In this way, combination of the CV7000 high-speed 3D imaging and projection functions facilitates the efficient analysis of 3D samples. Furthermore, the method can be applied to live cells to establish new experimental methods such as the time series evaluation of cells.
※Reorganized using the maximum intensity projection (MIP) function.

Original image

Fig. 1 (a): Original image
12 images were taken at 10 µm intervals in the Z-axis direction and displayed using MIP (a’) is the magnified section.

Large image

Recognition image

Fig. 1 (b): Recognition image
Spheroid contour (purple) and contained cells (blue) in image (a) recognized using analysis software (b’) is the magnified section.

Large image

Tile image

Fig. 2(a): Tile image(25 tiles) of the entire well including 50-pixel overlapping regions between adjacent tiles in the XY direction

Large image

Tile image

Fig. 2(b): Image created by combining the tile images in (a)

Large image

Experimental

  1. HeLa cells, in which Azami-Green was expressed, were inoculated in spheroid formation dishes (EZSPHERE®, AGC Techno Glass Co., Ltd.) (5×105 cells/dish) and cultured for seven days.
  2. Spheroids were collected, fixed, and inoculated again on 96-well plates. Images were captured using the CV7000 under the following conditions:
    ・Magnification: 10x (dry)
    ・Wavelength: 488nm
    ・Exposure time: 250msec
    ・12 images taken at 10µm intervals in the Z-axis direction over a distance of 110µm
    ・Images captured per plate: 25
     (The entire well was captured using the tile function; time required per well was approx. 1.5 minutes.)
  3. The maximum spheroid diameters and the number of contained cells in the MIP image were measured using the analysis software, and graphs were created using Spotfire®.

Experiment

 

Results and Conclusion

EZSPHERE® has fine pores on the cultivation surface, which is coated with a special polymer that is non-adhesive for cells. Inoculated cells, therefore, form uniform spheroids in the wells. Six types of dishes with wells of different diameters and depths (4,000-900, -901, -902, -903, -904, -905) were used to form spheroids, and images were captured and analyzed using the CV7000. As a result, the data obtained for the maximum spheroid diameters and the number of contained cells correlated with the sizes of spheroids predicted from the diameters and depths of the wells. In this way, the CV7000 allows for efficient evaluation even for 3D samples such as spheroids.

): Tile image of each well (numbers in the images are the model

Fig. 4 (a): Tile image of each well (numbers in the images are the model numbers of used dishes.)
900 (diameter: 500µm/ depth: 100µm), 901 (diameter: 200µm/ depth: 100µm)
902 (diameter: 500µm/ depth: 200µm), 903 (diameter: 800µm/ depth: 300µm)
904 (diameter: 800µm/ depth: 400µm), 905 (diameter: 1,400µm/ depth: 600µm)

 

Spheroid diameter

Fig. 4 (b): Spheroid diameter

Number of contained cells

Fig. 4 (c): (c) Number of contained cells

Spotfire® is a registered trademark of TIBCO Software Inc.


Our Social Medias

We post our information to the following SNSs. Please follow us.

  Follow us Share our application
•Twitter @Yokogawa_LS Share on Twitter
•Facebook Yokogawa Life Science Share on Facebook
•LinkedIn Yokogawa Life Science Share on LinkedIn

 

Yokogawa's Official Social Media Account List

Social Media Account List


Related Products & Solutions

  • CellPathfinder

    CellPathfinder는 HCA 시스템, CQ1 및 CellVoyager 시리즈용으로 설계되었습니다. 초보자부터 전문가까지 YOKOGAWA의 분석 소프트웨어를 사용함으로써 미묘한 생리학적 변화를 정량화 할 수 있으며 다양한 그래프 옵션을 사용하여 label-free 샘플까지도 정량화 할 수 있게 해 줍니다.

    See More
  • CV8000 High-Throughput System

    CellVoyager CV8000은 가장 진보된 최첨단 high-content screening 시스템입니다. 향상된 내장 인큐베이터를 통해 extended live cell 반응을 분석할 수 있습니다. 이 system의 확장성과 함께 4대의 카메라, 5개의 레이저 및 옵션 사양인 내장 피펫팅 기능을 갖춘 이 시스템은 점점 더 복잡한 검사 및 분석의 발전과 high-content screening을 가능하게 합니다.

    See More
  • High Content Analysis CellVoyager

    HCA(High-Content Analysis) 시스템은 당사의 강력한 소프트웨어와 함께 활용되어 기초 과학에서부터 복잡한 화합물 스크리닝에 이르기까지 광범위한 연구 응용 분야에서 활용됩니다. 

    See More
  • Life Science

    Yokogawa의 고밀도 분석시스템과 이중 회전 디스크 공초점 기술은 고속 및 고해상도 라이브 셀 이미징을 제공하여 전세계 최첨단 연구를 가능하게 합니다.

    See More

Top