LL50A

UTAdvanced ์‹œ๋ฆฌ์ฆˆ์˜ ํŒŒ๋ผ๋ฏธํ„ฐ์™€ ๋ž˜๋” ํ”„๋กœ๊ทธ๋žจ ๋“ฑ์„ PC์—์„œ ์ž‘์„ฑ · ์„ค์ •ํ•˜๊ธฐ์œ„ํ•œ ์†Œํ”„ํŠธ์›จ์–ด์ž…๋‹ˆ๋‹ค. ์กฐ์ ˆ๊ณ„์™€ ํ†ต์‹ ํ•˜๋ฉด์„œ ํŠœ๋‹๊ณผ ๋ž˜๋” ํ”„๋กœ๊ทธ๋žจ์˜ ๋ชจ๋‹ˆํ„ฐ๋ง์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

  • ๋‹ค์–‘ํ•œ ์—ฐ๊ฒฐ ๋ฐฉ๋ฒ•
  • ํŒŒ๋ผ๋ฏธํ„ฐ ์„ค์ • ๊ธฐ๋Šฅ
  • ํŠœ๋‹ ๊ธฐ๋Šฅ
  • ๋ž˜๋” ํ”„๋กœ๊ทธ๋žจ ์ž‘์„ฑ ๊ธฐ๋Šฅ
  • ๋„คํŠธ์›Œํฌ ํ”„๋กœํŒŒ์ผ๋ง

Details

ํŒŒ๋ผ๋ฏธํ„ฐ ์„ค์ • ๊ธฐ๋Šฅ

Parameter Setting Display

LL50A๋ฅผ ์ด์šฉํ•˜์—ฌ ํŒŒ๋ผ๋ฏธํ„ฐ ์„ค์ • ๋ฐ ํ”„๋กœ๊ทธ๋žจ ํŒจํ„ด ์ƒ์„ฑ ๋ฟ๋งŒ ์•„๋‹ˆ๋ผ ๋ฐ์ดํ„ฐ ๊ด€๋ฆฌ๋„ ์‰ฝ๊ฒŒ ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค. ๋˜ํ•œ ์„ค์ •ํ•œ ๋งค๊ฐœ ๋ณ€์ˆ˜๋ฅผ UTAdvanced์— ์ดˆ๊ธฐ ํŒŒ๋ผ๋ฏธํ„ฐ๋กœ ์ง€์ •ํ•˜์—ฌ ๋“ฑ๋ก ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค. (์ดˆ๊ธฐํ™” ์ž‘์—…์€ ์ „๋ฉด ํŒ๋„ฌ ํ‚ค์—์„œ๋„ ์‹ค์‹œ ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.)

ํŠœ๋‹ ๊ธฐ๋Šฅ

Tuning Display

UTAdvanced์˜ PID ๊ฐ’์„ ์ตœ์ ํ™” ํ•  ๋•Œ ์‚ฌ์šฉํ•˜๋ฉด ํŽธ๋ฆฌํ•ฉ๋‹ˆ๋‹ค. PID ๊ฐ’์˜ ์ˆ˜์ • ๋ฟ๋งŒ ์•„๋‹ˆ๋ผ ๋ชฉํ‘œ ์„ค์ •์น˜ (SP) ๋ณ€๊ฒฝ, ์ž๋™ / ์ˆ˜๋™ ๋“ฑ์˜ ๋ชจ๋“œ ์ „ํ™˜๋„ ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค. ํ™”๋ฉด์—์„œ SP / PV / OUT ๊ฐ’์„ ๋ชจ๋‹ˆํ„ฐํ•˜๋ฉด์„œ ์‹คํ–‰ ๊ฐ€๋Šฅํ•˜๋ฏ€๋กœ ๊ฐ„ํŽธํ•œ ํŠœ๋‹ ์ž‘์—…์ด ๊ฐ€๋Šฅํ•ฉ๋‹ˆ๋‹ค.

๋ž˜๋” ํ”„๋กœ๊ทธ๋žจ ์ž‘์„ฑ ๊ธฐ๋Šฅ

Ladder Program Building Display

๋ž˜๋” ์‹œํ€€์Šค ํ”„๋กœ๊ทธ๋žจ์„ ์ž‘์„ฑํ•˜๊ณ  ๋ž˜๋” ํ”„๋กœ๊ทธ๋žจ์„ ๋ชจ๋‹ˆํ„ฐ๋ง ํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

๋„คํŠธ์›Œํฌ ํ”„๋กœํŒŒ์ผ ์ƒ์„ฑ ๊ธฐ๋Šฅ

PROFIBUS-DP ํ†ต์‹ ์„ ์œ„ํ•œ ์žฅ์น˜ ๋ฐ์ดํ„ฐ ์‹œํŠธ๋ฅผ ์ƒ์„ฑํ•˜๋Š” ๋ฐ ์‚ฌ์šฉํ•  ์ˆ˜ ์žˆ์Šต๋‹ˆ๋‹ค.

Via Bus Powered USB Cable

Via Bus Powered USB Cable

Can be set parameters while no power supply to controller.

Via Ethernet Communication Connector

Via Ethernet Communication Connector

Via Dedicated Adapter

Via Dedicated AdapterCan be used while attached to the control panel.

  • Applicable Controllers: UT55A, UT52A, UT35A, UT32A
  • Applicable OS: Windows XP/Vista
  • Communication method: USB 1.1

Via RS-485 Communication Terminals

Via RS-485 Communication Terminals

์ž๋ฃŒ์‹ค

Confirm that there is a proper USB connection. If there is no problem with the connection, check whether the USB driver is installed correctly on the PC.
Upload means to read data on the LL50A from a controller. Download means to write data from the LL50A onto the controller.
To write the data from the PC to the controller, do a download.
Close all windows open in the lower right of the screen, such as the parameter setting window.
The LL50A comes with a dedicated USB cable, and a dedicated adapter for attaching to the main unit front panel.
The model is LL50A-00 (parameter setting software).
MODE (operation mode) related parameters do not appear.
The LL50A supports Japanese and English. The installer detects the language of the OS automatically.
Autotuning can be executed from the LL50A tuning monitor.
When you install the LL50A, two icons are create on the desktop. To write settings, launch the Setting Tool by clicking its icon.
Yes, in version R6.02.01 and later.Use File>Settings>Language. If parameters are not displayed, install the latest version of LL50A.
Check the following. Whether the dedicated cable is securely inserted into the adapter. The position of attachment to the front of the controller. In Device Manager, under Ports (COM and LPT), confirm that "Yokogawa USB Serial Port" ap...
You can protect it with a unique user password.
No, please use the included cable when you purchase LL50A.
The password is UTAdvanced_INIT_SET.
Yes. For LL50A communication that uses the maintenance port, the DCU version is R0.00.00.
Use the LL50A Parameter Setting Software, sold separately.
Yes, the UT75A + LL50A setting software (sold separately) can handle that.
Generally you should create programs in "user ladder" mode. If needed, you can rewrite the input ladder and output ladder portions.
The DATA register uses a 4-byte floating point number, therefore it displays a lot of digits. Try using the K or P registers, since they handle 2-byte integer data.
On the LL50A, change the system data's ladder sequence function from USE to DON'T USE. If not using the LL50A, initialize the main unit.
It won't start while the system data or parameter setting screen is displayed. Close those screens and restart.
Check the operation of the program on the LL50A ladder program monitor.
You can change it if it is in a user profile (profile no. 0).To create a user profile, use the LL50A network profile tool.
Yes, if using a UTAdvanced series instrument with the RS-485 communication option. Set the RS-485 protocol on the main unit to 8 (MBRTU: Modbus RTU). The initial value is 8. Select RS-485 in the LL50A communication execution screen, and make the comm...
If the LL50A's display setting is not PRO, some parameters won't display. Change the LL50A's display parameter as follows: Display > Parameter > Display level > Professional. The LL50A's display level must be set separately f...
As for individually writing parameters via CC-Link, changing OUT area values constitutes a write request. In your case, since the OUT area value hasn't changed from the previous value, the SP value is notoverwritten. As a fix, periodically copy t...
Yes, you can use the GREEN-UTAdvanced parameter data conversion tool (available as free download). Using the LL100/LL200 parameter setting tool, save the GREEN series parameters to a file, convert them using the conversion tool, then apply the settin...

Downloads

๊ธฐ์ˆ  ๋ฐ ์†”๋ฃจ์…˜, ์š”๊ผฌ๊ฐ€์™€์— ๋Œ€ํ•œ ์ž์„ธํ•œ ์ •๋ณด๋ฅผ ์ฐพ๊ณ  ๊ณ„์‹ญ๋‹ˆ๊นŒ?

๊ฒฌ์  ๋ฐ ๊ธฐ์ˆ ๋ฌธ์˜

Top