The LCD display of a R1 (fixed antenna) transmitter is continuously enabled under any one of the following conditions:
- Measurement mode of the transmitter is set to "continuous mode"
- Publish period is 1 second or less.
- There is an error message in the transmitter.
Changing items 1 or 2 or eliminating the error condition in item 3 will allow the transmitter to go back to disabled LCD display mode.
Productos y Soluciones Relacionadas
-
EJX510B Wireless In-Line Mount Absolute Pressure Transmitter
The high performance wireless absolute and gauge pressure transmitters EJX510B and EJX530B feature single crystal silicon resonant sensor and are suitable to measure liquid, gas, or steam pressure.
-
YTA510 Wireless Temperature Transmitter
The high performance temperature transmitter YTA510 accepts Thermocouple, RTD, ohms or DC mill volt inputs. The transmitters transmit not only process variables but also the setting parameters using wireless signal. The transmitters run on internal batteries, and the installation cost can be decreased since hard-wiring is not required. The communication is based on ISA100.11a protocol specifications.
-