List of FIST Completed Devices

List of FIST Completed Devices

About FIST
FDT/DTM Interoperability Support Test, where FDT stands for Field Device Tool and DTM stands for Device Type Manager. It is a program or activity in order to reinforce the interoperability between Yokogawa FDT Frame application and the DTM's of third party field device vendors.
DTM and frame application are being developed independently of one another, with the only prerequisite to comply with given FDT interfaces. The interaction can only work, when compliance with these interfaces can be ensured. Even though the FDT Group itself validates the DTM by a certification process, Yokogawa additionally has established an "Interoperability Test Lab" to verify the interoperability of the DTM's with our frame applications namely PRM and FieldMate.

About FDT / DTM
FDT (Field Device Tool) is a communication interface technology that enables communication between on-site field devices such as pressure sensors or flow meters and a control system, regardless of the communication protocol or the vendor of the field devices. 
DTM (Device Type Manager) is a driver software that is created by the control system vendors and field device vendors for their own products based on this FDT technology. 
With these vendor-provided DTMs that comply with the various communication protocols used in the control field, users can easily connect control systems and sensors from different vendors to build an optimal plant control system.

Device vendors or users who wish to have their DTM tested can apply for the test through "Contact Us", stating "FIST request” in your application.

The following device list shows the devices which have passed the YOKOGAWA FIST.

A : Altus    Azbil
B : Biffi
C : CodeWrights
D : Dresser Masoneilan   Draeger Safety
E : Emerson    Endress+Hauser
F : Fisher Controls    Flowserve
G : GE    General Monitors
H : HIMA
K : Krohne
M : Magnetrol    Metso Automation    MicroMotion Inc    MTL
P : Pepperl+Fuchs    Phoenix Contacts    PR Electronics    PROCENTEC
R : R STAHL
S : SAMSON    Schneider Electric    Siemens-AG    Softing
T : Top Worx    Trebing & Himstedt    TURCK
V : Val Controls    VEGA
W : Westlock Controls    WIKA

Number of FIST completed devices (DTM) : 178

Updated: August 01, 2019

Altus

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 PO5064 & AL-2434 Ponto Series PROFIBUS Head Gateway DTM & CommDTM PROFIBUS DP-V1 for AL-2434 PROFIBUS N/A N/A G/C 1.1.0.5/5.00.0(15) a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.00 - Pass

Azbil

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 AT9000 Advanced Transmitter HART 000D 1 D 1.1.1.182 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass
2 AT9000 Advanced Transmitter HART 360D 2 D 2.4.19.114 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass with Restriction Version R3.31.00 - Pass with Restriction
3 AT9000 Advanced Transmitter Model GTX Pressure Transmitter FF-H1 1501 1 D 2.6.15.75 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.10 - Pass with Restriction
4 AVP302-V2 Valve Positioner HART 0014 1 D 1.1.1
.167
a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass with Restriction
5 AVP302 Valve Positioner HART 0003 2 D 1.1.1
.441
a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass with Restriction
6 AVP700 Valve Positioner FF-H1 1701 1 D 2.6.15.75 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.10 - Pass with Restriction
7 AVP700 Valve Positioner HART 360F 1 D 2.4.19.116 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
8 MagneW 3000 Electromagnetic Flowmeter FF-H1 1601 1 D 2.6.7.38 a) FieldMate Information b) PRM Information
Version R2.06.01 - Pass Version R3.12.00 - Pass
9 Pro-V Flowmeter HART 0001 6 D 2.4.19.116 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction

Biffi

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 HRT IMVS 2000 Valve Monitoring System HART 007D 1 D 1.1.0 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass

CodeWrights

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 HART Communication Comm-DTM HART NA NA C 1.0.25 a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03 - N.A

Dresser Masoneilan

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 FVP (Soft DL) Valve Positioner FF-H1 0001 1 D 1.2.81.
108
/1.7.17
a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03 - Pass
2 SV II ESD Valve Positioner HART 00CB 1 D

1.00.0

a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
3 SVI II AP Valve Positioner HART 00CA 2 D 2.10.0 a) FieldMate Information b) PRM Information
Version R3.01.12 – Pass with Restriction Version R3.20.00 - Pass with Restriction

Draeger Safety

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 Polytron 8000 Gas Detector FF-H1 0001 1 D 1.0.0.1054 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.10 - Pass with Restriction
2 Polytron 8000 Gas Detector HART 52E8 2 D 2.2.0.701 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.10 - Pass with Restriction
3 Polytron 8000 Gas Detector PROFIBUS 0F22 2.0 D 1.0.0.1054 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.10 - Pass with Restriction

Emerson

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 Rosemount 3144P Field Temperature Transmitter FF-H1 3144 2 D 1.2.20.1 a) FieldMate Information b) PRM Information
N/A Version R3.30.00 - Pass with Restriction
2 Rosemount Analytical 700XA Field Temperature Transmitter FF-H1 2001 1 D 1.1.32 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
3 Rosemount Analytical 1500XA Field Temperature Transmitter FF-H1 2002 1 D 1.1.32 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
4 Rosemount 848T Field Temperature Transmitter FF-H1 0848 6 D 1.2.20.1 a) FieldMate Information b) PRM Information
N/A Version R3.30.00 - Pass with Restriction
5 Rosemount 848T Field Temperature Transmitter FF-H1 0848 7 D 1.1.32 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
6 Rosemount 644 Field Temperature Transmitter FF-H1 0644 2 D 1.2.20.1 a) FieldMate Information b) PRM Information
N/A Version R3.30.00 - Pass with Restriction
7 Rosemount 752 Fieldbus Remote Display Field Device Display FF-H1 0752 3 D 1.1.32 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
8 Rosemount 8732E Magnetic Flow Transmitter FF-H1 8732 2 D 1.1.32 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
9 Valve Automation CAM16 Electric Actuator HART E28B 1 D 1.4.181.1 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.20.00 - Pass
10 Valve Automation CAM228/CAM28 FF Electric Actuator FF-H1 EDC3 1 D 1.2.20.4 a) FieldMate Information b) PRM Information
Version R3.01.12 – Pass with Restriction Version R3.12.00 - Pass
11 Wireless Gateway Wireless Gateway DTM HART N/A N/A G 1.1.41 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
12 Rosemount 3051C Pressure Transmitter FF-H1 3051 8 D 1.0.14 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass Version R3.31.00 - N/A
13 Rosemount 3051S Pressure Transmitter W/L HART N/A 2 D 1.0.0.26 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
14 Rosemount 3051 SMV Pressure Transmitter FF-H1 3151 1 D 1.2.20.6 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass
15 Rosemount 5300 Series Level Transmitter FF-H1 5300 4 D 1.6.42.49 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
16 Rosemount 5400 Series Radar Level Transmitter FF-H1 5400 2 D 1.1.13.13 a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
17 Rosemount 8800 Vortex Flow Meter FF-H1 8800 10 D 1.2.20.5 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass with Restriction

Endress+Hauser

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 DELTBAR S Pressure Transmitter HART 0017 21 D 2.42.00 a) FieldMate Information b) PRM Information
Version R3.01.12 – Pass with Restriction Version R3.20.00 - Pass with Restriction
2 Levelflex FMP5x Guided Radar Level FF-H1 1022 2 D 2.42.00 a) FieldMate Information b) PRM Information
Version R3.01.12 – Pass with Restriction Version R3.20.00 - Pass with Restriction
3 Prosonic Flow 92F Ultrasonic flowmeter HART 0061 2 D 1.4.186.501 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass
4 Micropilot FMR5x Radar Level Transmitter HART 1128 3 D 1.8.0.689 a) FieldMate Information b) PRM Information
Version R3.02.00 – Pass with Restriction Version R3.31.00 – Pass with Restriction
5 RID1x (RID14/RID16) 8 Channel Field Indicator FF-H1 10CF 2 D 2.44.00 a) FieldMate Information b) PRM Information
Version R3.02.00 – Pass Version R3.31.00 – Pass
6 Promag 300/500 4-wire Electromagnetic Flowmeter FF-H1 103C 1 D 1.9.0.122 a) FieldMate Information b) PRM Information
Version R3.02.10 – Pass Version R3.31.00 – Pass
7 Promass 300/500 4-wire Coriolis Flowmeter FF-H1 103B 1 D 1.9.0.197 a) FieldMate Information b) PRM Information
Version R3.03.00 – Pass Version R3.31.00 – Pass
8 Liquiline pHORP pH/ORP Transmitter FF-H1 10A0 4 D 2.4.0.22 a) FieldMate Information b) PRM Information
Version R3.03.00 – Pass Version R3.31.00 – Pass
9 Liquiline Oxygen Oxygen Transmitter FF-H1 10A2 4 D 2.4.0.22 a) FieldMate Information b) PRM Information
Version R3.03.00 – Pass Version R3.31.00 – Pass
10 Liquiline Cond Conductivity Transmitter FF-H1 10A1 4 D 2.4.0.22 a) FieldMate Information b) PRM Information
Version R3.03.00 – Pass Version R3.31.00 – Pass
11 Prowirl 200 2-wire Vortex Flowmeter FF-H1 1038 2 D 1.11.0.174 a) FieldMate Information b) PRM Information
Version R3.03.00 – Pass Version R3.31.10 – Pass
12 TMT85 Temperature Transmitter FF-H1 10CE 2 D 1.6.55.40 a) FieldMate Information b) PRM Information
Version R3.04.00 – Pass Version R4.02.00 – Pass
13 TMT82 Temperature Transmitter HART 11CC 2 D 1.10.423.4213 a) FieldMate Information b) PRM Information
Version R3.04.00 – Pass Version R4.02.00 – Pass

Fisher Controls

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 DVC2000 FW 2 Valve Controller HART 0005 1 D 1.4.138.5 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00- Pass
2 DVC2000 FW 3 Valve Controller HART 0005 1 D 1.7.5 a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03 - Pass
3 DVC2000 Valve Controller HART 0005 1 D 12.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
4 DVC6000 H5 Valve Controller HART 0009 1 D 12.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
5 DVC6000 H7 Valve Controller HART 0009 2 D 12.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
6 DVC6000 Valve Controller HART 0003 2 D 13.1 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass Version R3.31.00 - Pass
7 DVC5000F Valve Controler FF-H1 5420 8 D 11.1 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
8 DVC6200F Valve Controller FF-H1 4602 2 D 12.1 a) FieldMate Information

b) PRM Information

Version R2.06.00 - Pass Version R3.11.00 - Pass
9 Fisher DVC6200f/DVC6000f Valve Controller FF-H1 4602 4 D 13.4 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R4.01.00 - Pass
10 DVC6000 SIS H5 Valve Controller HART 000A 1 D 12.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
11 DVC6000 SIS H7 Valve Controller HART 130A 2 D 12.3 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.20.00 - Pass with Restriction
12 DVC6200_H5 Valve Controller HART 0009 1 D 12.2 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.12.00 - Pass
13 DVC6200 HW2 H5 Valve Controller HART 1309 1 D 13.4 a) FieldMate Information b) PRM Information
Version R3.03.10 - Pass Version R4.01.00 - Pass
14 DVC6200_H7 Valve Controller HART 1309 2 D 12.2 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.12.00 - Pass
15 DVC6200 HW2 H7 Positioner HART 1309 3 D 13.4 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R4.01.00 - Pass
16 DVC6000F Valve Controller FF-H1 4601 1 D 12.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
17 Fisher DLC3020f Digital Level Controller/Transmitter Level Controller FF-H1 3020 1 D 1.1.32 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass

Flowserve

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 LX 3400MD Valve Positioner FF-H1 0203 1 D 1.6.33.
6
a) FieldMate Information b) PRM Information
R2.05.00 - Pass R3.10.00 - Pass
2 LX 3400MD Valve Positioner FF-H1 0203 2 D 2.6.5.
35
a) FieldMate Information b) PRM Information
R3.02.00 - Pass R3.31.00 - Pass
3 Logix500si/D2 DTM Digital Positioner FF-H1 0003 2 D 1.0.4 a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
4 LGX 3200MD Digital Positioner HART 0005 2 D 1.0.0.4 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
5 LGX 3200MD Plus Digital Positioner HART 0007 61 D 2.0.1.4 a) FieldMate Information b) PRM Information
Version R3.01.12 – Pass with Restriction Version R3.30.00 - Pass with Restriction
6 Limitorque Digital Positioner FF-H1 4D58 5 D 1.0.0.5 a) FieldMate Information b) PRM Information
R2.05.00 - Pass R3.10.00 - Pass
7 D3 HART Digital Positioner HART 00D3 1 D 1.1.5.2 a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03 - Pass
8 LGX 420 Digital Positioner HART 0009 61 D 1.0.0.0 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass with Restriction Version R3.12.00 - Pass
9 520MD Plus Digital Positioner HART 3007 71 D 2.0.0.2 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass with Restriction Version R3.12.00 - Pass with Restriction
10 Logix 3800 Positioner FF-H1 0301 1 D 1.0.0.4 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R3.31.10 - Pass
11 Logix 3820 Valve Actuator HART 000A 60 D 1.0.0.15 a) FieldMate Information b) PRM Information
Version R3.03.10 - Pass with Restriction Version R4.02.00 - Pass with Restriction
12 Logix 3820 Valve Actuator HART 300A 70 D 1.0.0.15 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass with Restriction Version R4.02.00 - Pass with Restriction

GE

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 SVI Positioner FF-H1 0008 1 D 1.00.0000 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
2 SVI Positioner FF-H1 0008 2 D 1.3.0.0 a) FieldMate Information b) PRM Information
N/A Version R3.30.02 – Pass with Restriction
3 SVI II AP H6 Positioner HART 00CE 2 D 2.20.0 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass with Restriction
4 XMT868i Ultrasonic Liquid Flow Transmitter HART 0070 1 D 1.0.0.264 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass Version R3.31.00 - Pass
5 XGF868i Ultrasonic Gas Flow Transmitter HART 0070 1 D 1.0.0.264 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass Version R3.31.00 - Pass

General Monitors

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 IR400 Point IR Gas Detector HART 0083 1 D 1.0.1.296 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass with Restriction Version R3.30.02 - Pass
2 FL4000H Multi-Spectral Infrared Flame Detector HART 0080 1 D 1.0.1.296 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass with Restriction Version R3.30.02 - Pass

HIMA

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 X-COM & X-HART Comm & Gateway DTM HART N/A N/A C/G 1.1.0.5/
1.0.0.0
a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass

Krohne

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 IFC 300 Flowmeter FF-H1 0300 3 D 1.0.8 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
2 MFC 300 Mass Flowmeter FF-H1 0320 3 D 1.0.3 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
3 ESK4 Volume Flowmeter HART 00D6 1 D 1.0.3 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
4 ESK4 Volume Flowmeter PROFIBUS 00D6 1 D 1.0.4 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
5 VFC 200 Vortex Flowmeter HART 45CD 1 D 1.0.7.3816 a) FieldMate Information b) PRM Information
Version R3.01.10 – Pass with Restriction Version R3.10.00 - Pass
6 ESK4 Variable Area Flowmeter and Level Meter FF-H1 0700 2 D 1.2.4.3851 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass Version R4.02.00 - Pass

Magnetrol

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 705-3x Guided Wave Radar Level Transmitter HART 00E5 1 D 1.4.102 a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
2 Eclipse Enhanced Model 705 3x R1 Guided Wave Radar Level Transmitter FF-H1 0001 1 D 1.6.20
.22
a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
3 Eclipse Enhanced Model705 3x R2 Guided Wave Radar Level Transmitter FF-H1 0001 2 D 1.6.20
.22
a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
4 Model_706 Guided Wave Radar Level Transmitter HART 56E0 1 D 2.4.23
.338
a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.20.00 - Pass
5 Model_706 Guided Wave Radar Level Transmitter FF-H1 0005 1 D 2.6.10
.76
a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.20.00 - Pass
6 Model R86 Non Contact Radar Level Transmitter FF-H1 0008 2 D 2.6.24.154 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass Version R4.02.00 - Pass

Metso Automation

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 ND9000PA Valve Positioner PROFIBUS 06CA 2 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R4.01.00 - Pass with Restriction
2 ND7000H Valve Positioner HART 00DE 3 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
3 ND7000H Valve Positioner HART 57DE 10 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
4 ND9000F Valve Positioner FF-H1 2328 2 D 1.15.15 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
5 ND9000F Valve Positioner FF-H1 2328 3 D 1.15.15 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
6 ND9000F Valve Positioner FF-H1 2328 5 D 1.18.9 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.20.00 - Pass
7 ND9000F Intelligent Valve Positioner FF-H1 2328 6 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
8 ND9000H Valve Positioner HART 00E5 2 D 1.15.15 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
9 ND9000H Valve Positioner HART 00E5 3 D 1.18.9 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass Version R3.20.00 - Pass
10 ND9000H Valve Positioner HART 00E5 4 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
11 ND9000H Valve Positioner HART 57E5 10 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
12 VG9000F Valve Positioner FF-H1 2329 1 D 1.15.15 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
13 VG9000F Intelligent Safety Solenoid with PST FF-H1 2329 3 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
14 VG9000H Valve Positioner HART 00D9 2 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
15 VG800 Valve Positioner HART 00EB 6 D 1.15.15 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.11.00 - Pass
16 SG9000H Valve Positioner HART 00D5 1 D 1.21.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction

MicroMotion Inc

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 2700 FF H1 Mass Flow Transmitter FF-H1 2000 6 D 1.0.0.14 a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03.00 - Pass

MTL

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 MTL 8000 Ethernet BIM Ethernet comm. DTM HART N/A N/A C 1.02.
0009
a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03 - Pass
2 MTL 4841 Serial Comm. DTM HART N/A N/A C 1.02.
0009
a) FieldMate Information b) PRM Information
Version R2.01.10 - Pass Version R3.03 - Pass
3 MTL 4850 Serial Comm. DTM HART N/A 1 C 1.07
.000
a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
4 MTL 4851 Serial Comm. DTM HART N/A 1 C 1.10.0
.788
a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
5 MTL F809F Fieldbus Diagnostic DTM FF-H1 0001 2 D 1.6.0 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
6

MTL F809F-Plus

Fieldbus Diagnostic DTM FF-H1 0001 3 D 2.5 a) FieldMate Information b) PRM Information
Version R3.03.10 - Pass Version R4.02.00 - Pass

Pepperl+Fuchs

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 KFD2-HMM-16 Multiplexer HART N/A N/A C 1.5.9 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00- Pass
2 MUX 2700G Multiplexer HART N/A N/A C 1.5.9 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
3 HD2-GT-2AD.FF.IO Diag. Gateway FF-H1 N/A N/A C 2.1.0.
1919
a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R 3.10.00- Pass
4 LB-FB Gateway DTM P + F modular Remote I / O system PROFIBUS N/A N/A G 7.6.3 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass with Restriction N/A
5 HD2-DM-A Advanced Diagnostic Module FDS Port N/A N/A G 2.2.0.2465 a) FieldMate Information b) PRM Information
Version R3.02.00 - Pass Version R3.31.00 - Pass with Restriction

Phoenix Contacts

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 Field Diagnostic Module Diagnoser FF-H1 0321 1 D 1.1.0.
368
a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass

PROCENTEC

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 ComBricks PROCENTEC DP-V1 Master PROFIBUS N/A N/A C 1.2.1.0 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass with Restriction N/A

PR Electronics

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 PRetop 5350 Temperature Transmitter PROFIBUS 5350 2.
03
D 1.20.
1006
a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
2 PRetop 5335 Temperature Transmitter HART 00EF 1 D 1.07.
0000
a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
3 PRetop 5337 Temperature Transmitter HART 6DEB 1 D 1.0.
1068
a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass

R STAHL

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 IS1 Remote I/O PROFIBUS N/A N/A D 3.0.1.0 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
2 DCM Diagnoser FF-H1 0001 1 D 1.0.0 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass

SAMSON

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 373x-3 Valve Positioner HART 00EF 4 D 1.2.22 a) FieldMate Information b) PRM Information
Version R2.02.00 - Pass Version R3.05.00 - Pass
2 373x-3 Valve Positioner HART 00EF 6 D 1.3.1 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
3 3730-5 Valve Positioner FF-H1 0002 2 D 1.0.0 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
4 373x-5 Valve Positioner FF-H1 0002 3 D 1.0.0.2 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass Version R4.01.00 - Pass
5 TROVIS 3793 Electropneumatic Positioner HART 42ED 1 D 1.1.0 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass Version R4.02.00 - Pass with restriction

Schneider Electric

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 Eckardt SRD960 Valve Positioner HART 0006 1 D 3.6.3 a) FieldMate Information b) PRM Information
Version R3.01.10 – Pass with Restriction Version R3.20.00 - Pass with Restriction
2 Foxboro IGP10S Series S Single Pressure Transmitter FF-H1 BA30 32 D 1.000.035 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass Version R3.31.00 - Pass

Siemens-AG

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 TH300 Temperature Transmitter HART 0013 1 D 3.1 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
2 SIPART PS2 Positioner HART 0015 4 D 3.1 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
3 SIPART PS FF Positioner FF-H1 0015 2 D 2.0 a) FieldMate Information b) PRM Information
Version R2.03.00 - Pass Version R3.05.01 - Pass
4 SITRANS VP300 Positioner HART 0020 1 D 3.1 a) FieldMate Information b) PRM Information
Version R2.03.00 - Pass Version R3.05.01 - Pass

Softing

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 Profibus Comm DTM PROFIBUS N/A N/A C 2.10 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
2 FG100 FF-HSE Comm DTM FF-H1 N/A N/A C 1.30.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass
3 FG110 FF-HSE Comm DTM FF-H1 N/A N/A C 1.30.1 a) FieldMate Information b) PRM Information
Version R2.06.00 - Pass Version R3.11.00 - Pass

Top Worx

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 DXP Valve Controller HART 0000 1 D 1.0.0.14 a) FieldMate Information b) PRM Information
Version R3.01.10 – Pass with Restriction Version R3.20.00 - Pass with Restriction

Trebing & Himstedt

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 xEPI2 Comm DTM PROFIBUS N/A N/A C 4.0.0.9 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass

TURCK

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 DPC-49 HSEFD/24VDC Diagnostic Power Conditioner FF-H1 N/A 1 D 1.30 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
2 EXCOM Remote I/O PROFIBUS N/A N/A D 1.10.
0012
a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass

Val Controls

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 IDC Diagnoser HART E2FA 3 D 1.1.2 a) FieldMate Information b) PRM Information
Version R3.01.12 – Pass with Restriction Version R3.20.00 - Pass
2 IDP Diagnoser HART E0D6 2 D 1.1.2 a) FieldMate Information b) PRM Information
Version R2.06.00 - N/A Version R3.11.00 - Pass
3 IVC Diagnoser HART E1F0 2 D 1.1.2 a) FieldMate Information b) PRM Information
Version R2.06.00 - N/A Version R3.11.00 - Pass

VEGA

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 VEGABAR 52 Pressure Transmitter FF-H1 076F 4 D 1.63 a) FieldMate Information b) PRM Information
Version R2.03.00 - Pass Version R3.05.00 - Pass
2 VEGABAR 80 Series FF Pressure Transmitter FF-H1 0BF9 2 D 1.79.0 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass with Restriction Version R3.31.00 - Pass with Restriction
3 VEGABAR 80 Series FF Pressure Transmitter FF-H1 0BF9 3 D 1.81.1 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R4.01.00 - Pass with Restriction
4 VEGAPULS63 Sensor FF-H1 0BFE 6 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
5 VEGAPULS 69 FF Radar sensor for continuous level measurement FF-H1 0BFA 2 D 1.79.0 a) FieldMate Information b) PRM Information
Version R3.02.10 - Pass Version R3.31.00 - Pass
6 MINITRAC31 Sensor FF-H1 0CF5 1 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
7 MINITRAC31 Sensor FF-H1 0CF5 3 D 1.79.0 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R3.31.10 - Pass with Restriction
8 VEGACAL62 Sensor FF-H1 076E 4 D 1.73.1 a) FieldMate Information b) PRM Information
Version R3.01.10 - Pass Version R3.12.00 - Pass
9 VEGACAL63 Sensor FF-H1 076E 4 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
10 POINTRAC31 Sensor FF-H1 0D48 2 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
11 POINTRAC31 Sensor FF-H1 0D48 3 D 1.82.0.12 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass Version R4.02.00 - Pass with Restriction
12 SOLITRAC31 Sensor FF-H1 0CF4 2 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
13 SOLITRAC31 Sensor FF-H1 0CF4 3 D 1.82.0.12 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass Version R4.02.00 - Pass with Restriction
14 FIBERTRAC31 Sensor FF-H1 0CF2 2 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
15 FIBERTRAC31 Sensor FF-H1 0CF2 3 D 1.82.0.12 a) FieldMate Information b) PRM Information
Version R3.04.00 - Pass Version R4.02.00 - Pass with Restriction
16 FIBERTRAC32 Sensor FF-H1 0CF3 2 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
17 WEIGHTRAC31 Sensor FF-H1 0CF8 2 D 1.67.2 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
18 VEGAFLEX81 Sensor FF-H1 0BF5 1 D 1.70.0 a) FieldMate Information b) PRM Information
Version R2.05.00 - Pass Version R3.10.00 - Pass
19 VEGAFLEX81 Guided Wave Radar FF-H1 0BF5 2 D 1.73.1 a) FieldMate Information b) PRM Information
Version R3.01.12 - Pass with Restriction Version R3.30.00 - Pass with Restriction
20 VEGAFLEX 80 Series Guided Microwave Transmitter FF-H1 0BF5 3 D 1.81.1 a) FieldMate Information b) PRM Information
Version R3.03.00 - Pass with Restriction Version R4.01.00 - Pass with Restriction

Westlock Controls

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 D-EPIC ESD Valve Positioner HART 0004 1 D 1.1.0 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass

WIKA

No. Model Description Protocol Dev Type Dev Rev DTM
Type*
DTM Version Yokogawa FDT Test Information
1 IPT-10 Pressure Transmitter HART 00E2 1 D 1.60.0 a) FieldMate Information b) PRM Information Notes & Remarks
Version R2.02.00 - Pass Version R3.05.00 - Pass This is a OEM device from VEGA and hence uses a VEGA DTM
2 T32 Temperature Transmitter HART 00EF 2 D 1.0.2 a) FieldMate Information b) PRM Information
Version R2.04.00 - Pass Version R3.10.00 - Pass
3 IPT-10 Pressure Transmitter PROFIBUS 5310 3.
32
D 1.80.
0000
a) FieldMate Information b) PRM Information
Version R2.03.00 - Pass Version R3.05.00 - Pass
4 T53.10 Temperature Transmitter PROFIBUS 5310 2.
03
D 1.11.
1001
a) FieldMate Information b) PRM Information
Version R2.03.00 - Pass Version R3.05.00 - Pass

C: Communication DTM
D: Device DTM
G: Gateway DTM

Related Products & Solutions

CENTUM VP DCS

Our most advanced control system ever, the CENTUM VP DCS enhances productivity and optimizes processes across a wide range of industries.

Top