Temperature Monitoring on PID loop at Steel Process

Introduction

ISA 100 WirelessDirect Reduction Iron (DRI) is one of the processes to reduce oxygen from iron oxide pellets for steel plant. More than 90% of DRI processes use heated LNG as process gas where PID control for temperature or interlock control is of vital importance.

 

Direct Reduction Iron

Requirement and Background

Reliable temperature measurement without frequent cable replacement is needed.

One of the major problems faced by the user is frequent replacements of cables as those gets degrade faster because of high ambient temperature and process vibrations. These cable replacements increases the operational cost as well as cost of man hours.

Solution

Temperature measurement over the radio as part of PID control loops, Interlock control loops and monitoring at DRI process were introduced. (For shaft furnace, gas reformer and other process pipes)

Highly reliable and full redundant wireless system realized this control loop application.

Two pairs of Redundant Access Point YFGW510 with a Duocast1 wireless communication were connected to a pair of Redundant Management Station YFGW410. Redundant Modbus TCP interface for non-Yokogawa DCS2 achieved stress free interoperability.

Result

The installation was completed in 2013 and the measured results for 120 temperature inputs were found satisfactory.

In dense area, out of line of sight devices up to 50m communicated successfully with less than 5% Packet Error Rate.

Benefits

  • Higher uptime of process
  • Operational cost reduction
  • Risk reduction: cable degradation, noise interference
  • Less installation costs and time: wiring, cable rack, junction box and etc.
Duocast System

Conclusion

This result proved that Yokogawa's high reliable wireless is very effective for DRI process. Deterministic routing algorism makes the communication latency shortest and fully redundant system with Duocast1 system can provide robust control loops. The High Performance "Radio Chip" embedded in these wireless devices helps to achieve High Quality Communications even in dense areas.

After 12 months or more operation, now the customer is considering expanding wireless applications in their site.

  1. Duocast: wireless redundant communication system standardized at ISA100 wirelessTM on double active access points with minimum wireless latency.
  2. The Yokogawa's CENTUM VP R5 or later supports dual-redundant network configuration with YFGW410 field wireless management station. It enables entire system full redundant. Please consult Yokogawa regional sales in case of engaging full redundant ISA100 wireless network system with 3rd party DCS.

 

업종

  • 철강

    철강 산업에서는 제품뿐만 아니라 제조 및 운영 기술의 품질을 향상시키고 환경 및 에너지 효율 문제를 해결하는 것 또한 중요합니다. Yokogawa는 고객이 이상적인 플랜트를 만들 수 있도록 돕고 동반 성장을 위해 발전해 나가고 있습니다.

    See More

Related Products & Solutions

  • YFGW410 현장 무선 관리 스테이션

    YFGW410 현장 무선 관리 스테이션은 국제 자동화 협회 (ISA)의 산업 자동화를 위한 무선 통신 표준 인 ISA100.11a를 기반으로 합니다. 이 제품은 ISA100.11a에 기반한 시스템 관리자 / 보안 관리자 / 게이트웨이 기능을 가지고 있으며 이를 현장 무선 수신기(YFGW510) 및 / 또는 현장 무선 미디어 컨버터 (YFGW610)와 결합하여 현장 무선 시스템을 구성합니다.

    See More
  • YFGW520 현장 무선 수신기

    YFGW520 현장 무선 수신기는 국제 자동화 협회 (ISA)의 산업 자동화를 위한 무선 통신 표준 인 ISA100.11a를 기반으로 합니다. 이 제품은 ISA를 기반으로 한 백본 라우터 기능이 있으며 현장 무선 관리 스테이션 (YFGW410) 및 / 또는 현장 무선 미디어 컨버터 (YFGW610)와 결합하여 현장 무선 시스템을 구성합니다.

    See More
  • YTA510 무선온도전송기

    고성능 온도 전송기 YTA510은 써모커플(열전대), RTD, 옴 또는 DC mV 입력을 받아 들입니다. 이 전송기는 무선 신호를 사용하여 프로세스 변수 뿐만 아니라 설정 Parmaeter도 전송합니다. 전송기는 내부 배터리로 작동하며 하드 와이어 링이 필요하지 않으므로 설치 비용이 감소 될 수 있습니다. 통신은 ISA100.11a 프로토콜 스펙을 기반으로 합니다.

    See More
  • YTMX580 다중 입력 온도 전송기

    YTMX580은 T/C (8 가지 유형 : K, E, J 등) 또는 RTD 신호 (3 가지 유형 : Pt100 등)와 같은 최대 8 개 측정입력을 받아 해당 측정 입력 값을 무선 신호로 변환 할 수 있습니다 . 또한 DC 전압, 저항 및 4 ~ 20 mA DC 신호 입력을 받아 들일 수 있습니다.

    See More
  • 현장 무선기기

    무선 솔루션 유연하게 적용함으로써 인프라에 대한 투자를 줄이면서 플랜트 운영에 대한 더 많은 이해할 수 있게 도와줍니다.

    See More

Top