Differential Pressure Transmitters

What is a Differential Pressure Gauge?

Differential pressure transmitters monitor and communicate the pressure measurements of equipment. Featuring DPharp technology, they deliver accurate, repeatable, and fast-responding measurements. Traditional mount or remote diaphragm seal mount configurations are available.

How Does a Differential Pressure Transmitter Work?

Differential Pressure (DP) transmitters measure the difference between two pressures. They use a reference point called the low-side pressure and compare it to the high-side pressure. Ports in the instrument are marked high-side and low-side. The DP level transmitter reading can be either negative or positive depending on whether the low-side or high-side is the larger value. A DP transmitter can be used as a gauge pressure transmitter if the low-side is left open to the atmosphere.

Digital Differential Pressure Transmitter

As part of a digital transformation, digital differential pressure transmitters can make data-gathering operations more efficient and safe for people. 

Common Industrial Applications

  • Closed Tank Level
  • DP Flow (Secondary Element)
  • Filter health
  • Density

What are the Different Types of Pressure Measurement?

View the differential pressure meter comparison chart.

Details

Which DP Level Transmitter Series Is Right for You?

  EJX-A Series EJX-A Series
EJA-E Series EJX-A Series
Accuracy
± 0.025%  
± 0.040%
± 0.055%  
Stability
± 0.1% of URL per 15 years  
± 0.1% of URL per 10 years  
Response Time
90 msec
Safety
FMEDA Report
IEC 61508 Certified (SIL 2)
Multi-sensing
Differential Pressure
Static Pressure

How Does a Differential Pressure Transmitter Work?

Differential Pressure (DP) transmitters measure the difference between two pressures. They use a reference point called the low-side pressure and compare it to the high-side pressure. Ports in the instrument are marked high-side and low-side. The DP reading can be either negative or positive depending on whether the low-side or high-side is the larger value. A DP transmitter can be used as a gauge pressure transmitter if the low-side is left open to the atmosphere.

Resources

Overview:

The Semiconductor industry uses ultrapure water to rinse away contaminants from the silicon wafers after each layer of the fabrication process. To ensure effective rinsing after each step could require thousands of gallons of water. If the water has even the slightest impurities, the semiconductors can potentially be contaminated, leading to scrap waste and loss of weeks of production. Many industries use reverse osmosis (RO) technology in the water purification process. The importance of pure water can include public safety, product quality, and reliability of production equipment. An RO system functions by creating a differential pressure across an array of filters. Pressure is applied to the feed water side of the system to force water through a semi-permeable membrane. The membrane blocks contaminants to allow permeate water to pass through.

Overview:

Accurate reactor level measurement enables flow optimization to enhance yield.

Industries:
Overview:

Download this eBook and learn:

  • The basic physics of pressure
  • Different types of pressure sensors
  • Features of pressure transmitters
  • Pressure transmitters communications standards
  • Key characteristics of pressure
  • Common types of diaphragm seals
Overview:

Read this eBook to learn how to best leverage the latest measurement instrumentation to avoid incidents and improve productivity. You will also find valuable information about overcoming common CIP challenges and stories of success.

Industries:
Overview:

Smart devices, like Yokogawa’s line of Total Insight transmitters and flowmeters contribute to Digital Transformation during operations and throughout the lifecycle of the instrument.

Edition 01 1
Overview:

Overcome Temperature Challenges. Correct common conditions for better level measurement.

Industries:
Overview:

Podcast: The benefits of a tried-and-true pressure-based level measurement technology.

Industries:
Pressure - Low Cut Output Signal With some applications, the output signal can be erratic as the input nears the zero point. One of the most common applications with this issue is differential pressure flow measurement. A differential pressure (DP) ...
Edition 1
High/Low Swap Sometimes during the rush of installing hundreds of devices, the impulse lines of a DP pressure transmitter can be plumbed to the incorrect ports on the transmitter. This error can go unnoticed even during the proof test stage...
Edition 2
It is a function on differential pressure (DP) transmitters that calculates the process flow using differential pressure readings. It is used on DP applications for flow measurement.
Edition 1
Overview:

It is a function on differential pressure (DP) transmitters that calculates the process flow using differential pressure readings. It is used on DP applications for flow measurement.

Overview:

Get the most from what exists currently and take advantage of new methods. Appeared in the March 2021 issue of an ISA.org publication.

Industries:

Downloads

Videos

Overview:

Podcast: The benefits of a tried-and-true pressure-based level measurement technology.

Overview:

Is it true that 4-20 mA HART will be phased out in the near future? Is a transducer equal to a transmitter? Tune in to hear the debunking of these myths.

Looking for more information on our people, technology and solutions?

Contact Us

Top