Nivel Automático

Introduction

Level transmitter configuration can be very time consuming. Calculations required to determine proper range values for traditional transmitters can become complex due to the physical layout of an application.

With maintenance shops getting smaller, finding equipment that allows us to do more with fens becomes a priority. DPharp transmitters with advanced software functionality can eliminate these complex calculations.

Application

Using typical smart or conventional products, all the following must be considered:

The specific gravity of the process SGP

Precise location of 0% and 100%

Specific Gravity of the capillary fill fluid
   (or sealing fluid used in impulse piping)

SGFF
Exact orientation oi the transmitter to the vessel H2
Vertical distance between the process conn. H1

Depending on the application, the vessel may be open (referencing atmosphere) or closed (under a blanket pressure).

Elevation is typically used when the vessel is closed. To reference the blanket pressure, a low side remote seal may be used (or a wet leg). The capillary on remote seal creates a negative force on the transmitter equal to the vertical height times the specific gravity of the fill fluid.

Elevation = (H1 + H2) x SGFF

Suppression is a positive pressure created on the high-pressure side of the transmitter typically due to the transmitter being positioned below the 0% process connection. Suppression is present in both open arid closed vessels. Suppression is equal to the vertical distance between the 0% process connection and the transmitter times the Specific Gravity of the fill livid.

Suppression = H2 x SGFF

Span is the vertical distance between the process connections times the process medium's Specific Gravity.

Span = H1 x SGP

Figure 1: Closed Tank
Figure 1: Closed Tank

Now that you have the Elevation, Suppression, and Span, the calibration values can be calculated for the 0% (Empty) arid the 100% (Full).

Cal Value (0%) = Suppression - Elevation

Cal Value (100%) = (Suppression + Span) - Elevation

Example: (using figure 1)

SGP 0.9 H2 10 inches
SGFF 0.8 H1 20 inches

Cal Value 0%) = Suppression - Elevation
Cal Value (0%) = (H2 x SGFF) - (H1 + H2 x SGFF)
Cal Value (0%) = (10 x 0.8) - (20 + 10) x 0.8
Cal Value (0%) = 8 - 24
Cal Value 0%) = -16 inH2O

Cal Value (100%) = (Suppression + Span) - Elevation
Cal Value (100%) = ((H2 x SGFF) + (H1 x SGP)) - (H1 + H2) x SGFF
Cal Value (100%) = ((10 x 0.8) + (20 x 0.9)) - (20 + 10) x 0.8
Cal Value (100%) = (8 + 18) - 24
Cal Value (100%) = +2 inH2O

Therefore, Calibrated Range would be:

-16 inH2O  +2 inH2O
0% 100%
Empty Full

Industrias

Productos y Soluciones Relacionadas

Flujo Bajo

Utilizando la ecuación de Bernoulli, los transmisores de Presión Diferencial pueden usarse para calcular el flujo del fluido a través de una tubería.

Flujo Másico (Multivariable)

Existen varias tecnologías en el mercado para medir el flujo másico. Una de ellas es el Transmisor de Presión Multivariable.

Multi-Detección

Un transmisor con Multi-Detección combina un transmisor de presión diferencial, un transmisor de presión del manómetro, y un transmisor de temperatura en un solo instrumento de campo.

Nivel Líquido

Las lecturas precisas de los niveles son esenciales para el funcionamiento seguro, confiable y rentable de su planta. Los transmisores de nivel de líquido miden la presión diferencial para calcular el nivel en un recipiente.

Presión Absoluta

Los transmisores de Presión Absoluta comparan una presión relativa contra la presión Absoluta. La presión Absoluta siempre tiene valor positivo.

Presión Corriente

Los transmisores de Presión Corriente son un tipo único de transmisor diferencial diseñados para medir las pequeñas diferencias en ambientes donde la presión estática es muy baja.

Presión del Manómetro

Los transmisores de Presión del Manómetro comparan una presión relativa contra la medición atmosférica.

Presión Diferencial

Los transmisores de presión diferencial comparan dos presiones y envían la diferencia a una unidad de control. El transmisor de presión diferencial tiene un número ilimitado de aplicaciones industriales.

Transmisores de Presión

El proceso de medición preciso y estable de los transmisores de Presión de Yokogawa son la base de la operación rentable, segura y confiable de su planta.

×

 

 

¿Tiene Dudas?

Contacte a un Experto de Yokogawa y conozca como podemos ayudarle a resolver sus retos.

Top