ADMAG AXF
Notice: This product was discontinued on May 7, 2021. See this replacement product:

The ADMAG AXF is the magnetic flow meter which has adopted the proven Dual Frequency Excitation. Moreover, the Enhanced Dual Frequency Excitation has been newly added to tackle more severe applications.

The AXF has user-friendly functions; such as an electrode adhesion level diagnosis function, infra-red switches which can be used for setting parameters without opening the case cover, ability to change the direction of electrical connection on the site.

Based on FOUNDATION™ fieldbus specifications, AXF Fieldbus models offer more flexible instrumentation through a higher level communication capability and propose the cost reduction by multi-drop wirings with less cables. FOUNDATION™ fieldbus is a registered trademark of Fieldbus FOUNDATION.

Note: The "Dual Frequency Excitation Method" is a Yokogawa innovation.

ADMAG Converters and Related Products:

AXFA14G
AXFA11
Sanitary Magnetic Flow Meters

Details

User-oriented Functionality

Fluid Adhesion Level Diagnosis
The amount of insulating material on the electrode is constantly monitored to determine when maintenance should be performed. An optional replaceable electrode is easy to remove and clean.

Flexible Electrical Connection Direction
The converter or the terminal box can be rotated in either direction to match the position of the electrical connections at the installation site.

Clear and Versatile Indications
The large, backlit full dot matrix LCD can display a variety of messages up to three lines in length. When an alarm condition occurs, a full description of the appropriate countermeasure is displayed.

Easy Setup
The most frequently used parameters are arranged in a group at the top of the display. Infrared switches enable the setting of parameters without opening the cover.

Operation Immediately after Installation
The AXF is shipped with the main parameters completely set and can go into operation as soon as installation and wiring are completed.

Expansion of Product Lineup

Improved Accuracy Specification
The standard accuracy is 0.35% of reading. Also available as an option is high accuracy calibration rated at 0.2% of reading.

Extra Small Size Flange Type
Flange types are now available in sizes as small as 2.5 mm.

Variety of Sanitary Connections
A wider variety of sanitary connections are now available, including Tri-Clamp, ISO, DIN and SMS.

Enhanced Performance

Enhanced Dual Frequency Excitation
The enhanced dual frequency excitation method is available as an option. This provides highly stable measurements involving high concentration slurries or low conductivity fluids.

Lower Minimum Conductivity
The newly designed AXF converter permits the measurement of fluids with conductivity as low as 1μS/cm depending on the nominal pipe size and fluid condition.

High-Speed Pulse Output
The maximum rate for high speed applications such as short-duration batch processes is now 10,000 pps (pulses per second).

  AXF
Remote Flowtube
AXF
Integral Flow meter
AXFA14
Converter
AXFA11
Converter
Size 2.5 to 400 mm
(0.1 to 16 inch)
[depends on specifications]
2.5 to 400 mm
(0.1 to 16 inch)
[depends on specifications]
Combined with Remote type flowtube
2.5 to 400mm
(0.1 to 16 inch)
Combined with Remote type flowtube (Note)
2.5 to 1800 mm
(0.1 to 16 inch)
Type of Use General-purpose use,
Ex-proof type,
Sanitary type,
Submersible type
General-purpose use,
Ex-proof type,
Sanitary type
General-purpose use,
Ex-proof type
General-purpose use
Fluid Temp. -40 to 160 deg.C
(-40 to 320 deg.F)
[depends on specifications]
-40 to 130 deg.C
(-40 to 266 deg.F)
[depends on specifications]
- -
Ambient Temp. -40 to 60 deg.C (-40 to 140 deg.F) [depends on model type]
Accuracy 0.35% of rate (Optional ; 0.2% of rate)
Fluid Conductivity 1 micro-S/cm or larger (depends on nominal pipe size and fluid condition)
Lining Fluorocarbon PFA/Ceramics/Polyurethance Rubber/
Natural Soft Rubber [depends on model type]
- -
Process Connection Wafer, Flange, Sanitary connections
(Clamp[Tri-clamp, DIN, ISO], Union thread[DIN, ISO SMS], Butt-weld), etc.
- -
Maximum Cable Length - - 100m (330 ft) 200m (660 ft)
Indicator - Multi line backlit LCD (Full dot-matrix)
Diagnosis Adhesion diagnosis, Empty pipe, Coil open, etc.
Alarm message Alarm message with corrective measures is indicated (English, German, French, Italian, Spanish, Japanese)
Excitation method Dual Frequency Excitation: AXF sizes 2.5 to 400 mm,
Enhanced Dual Frequency Excitation (optional): AXF sizes 25 to 200 mm
Pulsed DC Excitation: AXW sizes 500 to 1800 mm (Note)
Ex-proof type ATEX, FM, CSA, IECEx, TIIS -
Options Replaceable electrode, Rotatable terminal box(converter), Mirror finished lining surface(for PFA/Ceramics), Special gaskets, etc.

Refer to GS sheet for details.
Note: AXFA11 Converter can be also combined with AXW Remote Flowtube.

PROFIBUS is an open, digital communication system which covers factory and process automation. The GSD and EDD files can be downloaded here.

Product GSD file EDD file
ADMAG AXF Magnetic Flowmeter AXF_PA_GSD_00.zip(11KB) AXF_PA_00.zip(420KB)

Note: There are two types of GSD file in the AXF_PA_GSD_00.zip folder.

Device Specific GSD YEC4590.gsd
Profile GSD file PA139740.gsd

Note: Device Type Manager (DTM)
Please download at FDT/DTM Download Area.
(Move to Yokogawa Europe web page)

Resources

Overview:
  • More than 1,000 field devices designed to the PROFIBUS specifications installed in the state-of-the-art water reclamation plant.
  • The high reliability and accuracy of our field devices contributes to the minimization of maintenance costs over the entire plant lifecycle.
Overview:
  • To bring the customer a real-time monitoring and management capability, Yokogawa installed STARDOM (FCJ), flow meters, and transmitters at key points throughout the distribution network.
  • The STARDOM FCJ controllers achieved an accurate water loss management system while keeping the running costs to a minimum.
Overview:

Water Supply Treatment
FAST/TOOLS, STARDOM, Flowmeters, Liquid Analyzers

  • Bali's water treatment plant decided to employ the latest reliable control system in order to increase availability and quality of operation.
  • Centralized control system using FAST/TOOLS provides the sophisticated and flexible operation.
Overview:
  • CENTUM VP Batch package improves productivity.
  • Reduction of operator workload and safe operation.
Industries:
Overview:
  • The aging DCS system was replaced with an integrated control system for all processes at the Siheung water treatment plant.
  • Powerful Modbus communication function of STARDOM enables integration with the existing HMI via the OPC gateway.
Overview:
  • As the main automation contractor (MAC) for this plant construction project, Yokogawa Brazil engineered, installed, and commissioned an integrated control and instrumentation solution
  • Yokogawa Brazil completed the commissioning of these systems ahead of schedule and the production of green polymer was started just one week later
Industries:
Application Note
Overview:

Yokogawa's ceramic liner can offer the customer superior resistance to thermal shock and the failure that can occur due to liner cracking. This is due to Yokogawa's use of 99.9% pure Al2O3 for the liner.

Industries:
Overview:

This paper introduces the ADMAG AXR 2-wire magnetic flomwmeter solution for dust collection water application of steel converter.

Industries:
Application Note
533 KB
Overview:

To technology in iron & steel industry is continuously improved to obtain the best possible performance. The improved plant performance gives rise to the higher quality improvement and lower cost, and simultaneously environmental friendly plant operation.

Industries:
Overview:

The pulp and paper industry holds some of the most aggressive and challenging applications for magmeters. There are corrosive chemicals, high temperatures and pressures, and abrasive slurries. One application which is particularly difficult is the measurement of pulp stock from the digester to the blow tank. Yokogawa can provide one of the most reliable and accurate meters for this application.

Overview:

Plant consists of numerous outfall meter locations. These remote locations need to be monitored and the flow signals brought into the DCS system. There is AC power available at each site but currently no way to bring back analog signals along the existing infrastructure. Each location will have a Yokogawa AXF Magnetic Flow meter installed. The (4) sites current listed below will need to be connected to the Suwanee River Chemical Plant. There will be more sites added in the future.

Yokogawa Technical Report
Overview:

Yokogawa Electric Corporation promotes the standardization of FOUNDATION™ fieldbus as the communication foundation supporting Asset Excellence for VigilantPlant, which is an approach aimed at the advancement of plant instruments and equipment. With the recent dramatic advancement of fieldbus technologies, information processing technologies, and network speed, it has become possible to process various kinds of information inside the field sensors and transmit the results to the distributed control system (DCS) and host computer.

Yokogawa Technical Report
Overview:

After having undergone several improvements, magnetic flow meters have become highly accurate and reliable and are widely used in the industrial instrument field today. Magnetic flow meters consist of a detector and a converter, with the principle of the detector adopting Faraday's electromagnetic induction law.

Yokogawa Technical Report
Overview:

In 1988, Yokogawa launched the ADMAG series of magnetic flow meters with increased resistance to fluid noise and zero stability, employing dual frequency excitation which was developed based on its long-cultivated technology for flow measurement. Since then, the ADMAG family has augmented its application range with such models as explosion-proof and integral types, and a capacitance type.

Overview:

Recent or pending air pollution legislation to reduce the amount of air pollutants is increasing worldwide. In the U.S., The Clean Air Act address numerous air quality problems. One of these problems is acid rain (much of which falls in Canada) caused by sulfur dioxide and nitrogen oxide emissions from fossil-fueled power plants and other industrial and transportation sources.

Sizes 2.5 to 10 mm (0.1 to 0.4 in): 5 µS/cm or greater Sizes 15 to 125 mm (0.5 to 5 in): 1 µS/cm or greater Sizes 150 to 400 mm (6 to 16 in): 3 µS/cm or greater When conductivity is below the 3 µS/cm, we recommend using ...
​Per the general specifications (GS), units must be 1-12", PFA or Polyurethane Rubber liner, and the electrode material must be 316L stainless steel only. Also, replaceable electrodes must be ordered with the initial flowmeter because electrodes...
For an integral flowmeter: 12 W For a remote flowtube combined with an AXFA11 converter: 20 W For a remote flowtube combined with an AXFA14 converter: 12 W 
The standard accuracy for the output of an AXF is 0.35% of Rate/Reading. Yokogawa also offers a high grade accuracy calibration option which provides an accuracy of 0.2%.

Downloads

Engineering Tools

2D/3D Configurator

Looking for more information on our people, technology and solutions?

Contact Us

Top