EJX130A

The EJX130A is a traditional-mount, high-static differential pressure transmitter. Featuring a DPharp digital sensor, it offers the performance and device intelligence needed for greater process insight.

Details

What Are the Benefits of Pressure Transmitters?

 

Routine maintenance is easier with Yokogawa pressure transmitters. Efficient and effective maintenance through extended calibration intervals and simple trouble shooting.


 

Extended Calibration Intervals

Reduce maintenance cost by 33%.

Improved long-term stability extends calibration intervals. Spend your time where it is needed.

Quicker = Less Downtime

 


 

Multiple Communication Options

FieldMate PC based communication platform allows management of your entire instrument inventory.

FieldMate HHC allows you to take that information into the field.

LPS can update 9 parameters in the field without the use of an HHC.

Save time, Save money

 


 

Simple Troubleshooting

Local intuitive display with simple error messaging.

NE107 compliant alarms in FieldMate make troubleshooting easy.

Save time, Save money

 


 

Universal Mounting

Reduce stock by 50%.

Consolidate inventory of different flange configurations. Yokogawa transmitters are available with flanges using flexible vent and drain locations to met any installation need.

High Inventory = Stagnant Money

 

 


 

Safety as Standard

Reduce stock.

No need to stock separate inventory for safety and non-safety applications. With safety as a standard, Yokogawa transmitters can be used for either application.

 


 

Standard Protocols

No training required.

Yokogawa transmitters support all industry standard field device protocols. Interoperability and interchangeability can be ensured. Use the same tools and work procedures as before.

No Learning Curve = Smooth Change Over

 

 

 

Standard Industry Connections

Process connections designed to meet IEC61518 ensure you will not meet proprietary manifolds or accessories that limit your design choices.

How to Reduce Total Cost of Ownership?

Plants run better with Yokogawa pressure transmitters. At its heart, Yokogawa's High-static Differential Pressure Transmitter with DPharp sensor offers the performance and device intelligence needed to get greater insight into your process.


 

Digital Performance

Installed performance 2x better using all digital DPharp pressure sensor.

Yokogawa’s digital sensor provides superior performance and stability compared to analog sensors.

Poor Performance = Lost Money


 

More Information

Save up to 20% on CAPEX spending using our transmitter’s multi-sensing capability.

Using digital communication, one EJX130A can supply your control system with Level (Primary variable), Blanket Pressure (Secondary variable), and Sensor Temperature (Third variable)—eliminating the need for multiple transmitters.

More Information = Found Money

 


 

Standard Diagnostics

Reduce unscheduled maintenance by 60%

Over 40 diagnostics to ensure everything is OK. Active Sensor Technology monitors the DPharp sensor while the Patented Back-check Technology is reverse checking all calculations in real-time.

Good Diagnostics = Less Surprises

 

How Are Pressure Transmitters Built?

 

Yokogawa pressure transmitters help plants run longer. Yokogawa's DPharp active sensor, patented back check diagnostics, and rugged construction allow users to run their plants safer and with less downtime.


Rugged Construction

Reduce failures in the field by 200%.

Yokogawa transmitters are designed to out live your plant.

Ruggedness = Reliability

 

 

 

 

 


 

Over-pressure Protection

Reduce failures and calibrations.

Yokogawa DPharp pressure transmitters have an integral over-pressure mechanism to protect your transmitters from process surges or improperly sequenced manifolds.

 


 

Independent Verification

Reliability verified independently by third party industry experts.

 

 


 

Inherently Safe

Save up to 10% on CAPEX spending.

All Yokogawa pressure transmitters are certified to meet IEC61508 for single use in SIL 2 applications or dual use in SIL 3 applications as a standard. No special option needed! To Yokogawa, safety should never be an option.

Inherently Safe = Reliability

 


 

Active Sensor Technology

Unlike other sensor technologies, the active DPharp sensor constantly produces a signal even if there is no change in the process. This signal is continually monitored by the CPU.

 

EJX130A Overview

Measurement Types
Primary Variable Differential Pressure
Secondary Variable Static Pressure
Reference Accuracy
Primary Variable ±0.04% of Span
Secondary Variable ±0.2% of Span
Response Time
Primary Variable 150 msec
Secondary Variable 360 msec
Long Term Stability
Primary Variable ±0.1% of URL per 15 years
Over-pressure effect
Primary Variable ±0.03% of URL
Rangeability
Primary Variable 100:1

EJX130A Capsules

MSG005.a

MSG006.a

Graphics not to scale.

Valves

Manifolds

For Differential pressure transmitters, Yokogawa offers a complete line of 61518 IEC compliant 3-valve and 5-valve manifolds. Available in T-Style, H-Style, Wafer-Style, and Bottom Process Connection Style, they can be ASME B31.1 (Power) Compliant, ISA 15848 Compliant, or TA-Luft Compliant.

Learn More

 

The EJX130A is a traditional-mount high-static Differential Pressure Transmitter designed to measure accurately, transmit quickly, and do it reliably over time.

Resources

Overview:

DPharp performance in boiler drum level measurement applications is superior to metallic capacitance type pressure transmitters. Improved performance can be attributed to the unique resonant silicon sensor design with dual resonators.

Industries:
Edition 01 1
Overview:

Overcome Temperature Challenges. Correct common conditions for better level measurement.

Industries:
FieldGuide
688 KB
FieldGuide
756 KB
FieldGuide
493 KB
FieldGuide
632 KB
FieldGuide
1.0 MB
FieldGuide
659 KB
Overview:

Discover the safety features built-in to the Yokogawa digital pressure sensors (DPharp).

FieldGuide
813 KB
FieldGuide
708 KB
FieldGuide
608 KB
FieldGuide
741 KB
FieldGuide
743 KB
FieldGuide
658 KB
FieldGuide
717 KB
FieldGuide
584 KB

Downloads

Videos

Overview:

Is it true that 4-20 mA HART will be phased out in the near future? Is a transducer equal to a transmitter? Tune in to hear the debunking of these myths.

2D/3D Configurator

Looking for more information on our people, technology and solutions?

Contact Us

Top