  • Single loop controllers receive temperature, flow rate, pressure, and other types of measurement readings from sensors and send corresponding instructions to control elements such as valves in order to maintain these values within a desired range.

  • UTAdvanced temperature controllers and digital indicating controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities.

  • The UP35A/UP55A, 1/4 DIN sized program controllers, provides up to 30 program patterns, and simultaneous monitoring of 8 PV events, 16 time events, and 8 alarms.

  • The UM33A provides up to 9 alarms outputs and input correction function (PV bias, Polygonal line approximation, polygonal line bias). Also, 24 VDC sensor power supply is available as an option.

  • 1/16 DIN and 1/4 DIN sized Limit Controllers are FM approved, and configurable either as High or Low limit controller, and universal input, timer for exceeded duration.

  • The software packages enable to set controllers configuration parameters or create custom computation programs via the optical communications adapter attached on controller front panel.

  • The SMART 920 allows you to collect data from your entire site without the high cost of wiring points to remote or unpowered locations.

Application Note
Overview:

The making of ceramics is one of the oldest forms of heat-treating known to man. Clay, silica or some type of high purity alumina is shaped, dried, milled and then baked at extremely high temperatures. This high baking process changes the clay material to stone or glass. Depending on the properties that are desired from the end product will determine the material used and the method of firing the work.

Overview:

Yokogawa first introduced its renowned SUPER CONTROL™ in industrial controllers over a decade ago. This is a fuzzy logic alogrithm that eliminates overshoot from the desired set point and mimics the control expertise of the most experienced operator.

Overview:

LNG Industry, Summer 2012

Martin te Lintelo, Yokogawa, The Netherlands, discusses the need for better automation, measurement and control instruments to cope with the rising popularity of LNG.

Overview:

The proprietary USB cable for the YSS1000 software is not  available separately and is only available as part of the YSS1000-00  programming package.

Order the software and USB cable using the part number "YSS1000-00".

Overview:

The proprietary USB cable for the LL50A software is not available separately and is only available as part of the LL50A-00 programming package. Order part number LL50A-00.

Overview:

I purchased a YS1500/YS1700 without communications and now realize I need serial and/or Ethernet capabilities.  Is this possible?

It is not possible to add the Ethernet (/A34) option to the YS1500/YS1700 controllers.  However it is possible to add RS-485 (/A31) or DCS-LCS (/A32) communications.  The controller has to be returned to Yokogawa for this retrofit. Contact our service department at 800-524-7378 for more information.

Overview:

Terminals 16(+) and 17(-).

Overview:

Use the Advance function.  After you start the program, hold down the SET/ENT key for a few seconds. Hold will appear on the display. Release the Set Enter and then press it again 1 time. You will see ADV (the V looks like an upside down A). Press the up arrow to change OFF to ON and press SET/ENT; that will advance your program 1 segment. You may have to do this multiple times to get to the segment you want.

Overview:

Make sure you choose an input type, even if you are not using an input.

Overview:

The ethernet-serial gateway function allows a controller equipped with an Ethernet interface to communicate with other controllers via their RS-485 serial communication interface. The Ethernet-equipped gateway controller connects to a host computer using Modbus TCP protocol, and it also allows the host computer to access each of the connected serial devices via the gateway Ethernet functions. UT75A UT55A UT35A UP55A and UP35A models support this function.   

Overview:

The UTAdvanced line is made up of the following devices:UM33A, UT32A, UT35A, UP35A, UT52A, UT55A, UP55A and the UT75A.

Overview:

The YSS1000 software version R2.02.01 and above, supports the following operating systems:   -Windows XP Professional (Service Pack 2 or later) (32-bit version)-Windows Vista Business (32-bit version)-Windows 7 Professional (32-bit/64-bit versions)-Windows 8 Pro (32-bit/64-bit versions)

Overview:

The LL1100/LL1200 software version R1.07.01 and higher supports the following operating systems: -Windows XP (Home Edition/Professional , 32 bit version )-Windows Vista Business (with Service Pack 1, 32 bit version )-Windows 7 Professional (32 bit/64 bit versions)

Overview:

The YS1000 series includes the folloing devices:YS110, YS1310, YS1350, YS1360, YS1500, and the YS1700.

Overview:

The YS1700 "hard manual" only controls the first analog output (Y1).

Overview:

The software can be downloaded from this link on the Yokogawa website.  The software is free of charge.   If your controller has the /A34 option, then you can do configuration over Ethernet.  If your controller does not have the /A34 Ethernet option, you will need to purchase a programming cable that is USB to an RJ11 connector which plugs into the front of the controller (behind lift up face plate).

YSS1000 Programming Software

 

Overview:
  • The CX1000/CX2000 use the following file extensions:
    • Display data file: Mddhhmma.CDS
    • Event data file: Mddhhmma.CEV
    • Manual sample data file: Mddhhmma.DMN
    • TLOG data file: Mddhhmma.DTG
    • Hourly data file: Mddhhmma.DHR
    • Daily data file: Mddhhmma.DDR
    • Weekly data file: Mddhhmma.DWR
    • Monthly data file: Mddhhmma.DMR
  • For reference:
    • M: Month (1-9 for January-September, X-Z for October-December)
    • dd: day
    • hh: hour
    • mm: minute
    • a: the lowest digit of the year (0 to 9, except if another file with the same month, day, hour, and minute exist, in which case, “a” to “z” are assigned in alphabetical order).

Webinars

    Overview:

    Modbus is a serial communications protocol originally published in 1979 for use with its Programmable Logic Controllers (PLC). It has since become a standard communication protocol and is now a commonly available means of connecting industrial electronic devices.

    In this Webinar we will get into the details of how to make Modbus work.

    Sign up and learn more about:

    • Modbus configuration: master/slave or client/server
    • Modbus deployment: steps to commissioning a new installation
    • The physical layer of Modbus: wiring
    • Modbus demonstrations
    Overview:

    Having knowledge of the different tuning elements and how to adjust them can help you bring these unruly loops under control. If you have the responsibility to keep the processes running at your plant or factory, this webinar will help you better understand the basics of PID control.

    In this webinar you will learn:

    • The purpose of each of the PID tuning elements
    • How adjusting the individual PID elements will affect the process
    • General PID profiles for pressure / flow loops
    • General PID profiles for temperature loops
    • An explanation of some supporting parameters like cycle time, manual reset, and anti-reset windup